Article
[Study on second filtering algorithm based on tracing the interfering spectral peaks of radar non-contact life-parameter detection system].
Biomedical Engineering Department, Fourth Military Medical University, Xi'an 710032, China.
Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi
09/2006;
23(4):695-8.
pp.695-8
Source: PubMed
-
Citations (0)
- Cited In (2)
-
Article: Study of the ballistocardiogram signal in life detection system based on radar.
[show abstract] [hide abstract]
ABSTRACT: In this article, our study of non-contact method via radar for monitoring the heart and respiratory rates of human subject is reported. The system is constructed which synchronously detects the electrocardiogram signals by the electrocardiograph and the ballistocardiogram signals by the non-contact life parameter detecting technology. Also, the detected signals are analyzed respectively in the time and frequency domain. The results show that the cycle of the ballistocardiogram is obvious in time domain and that the rhythm of the two kinds of signals keeps consistent. And their characteristic points in frequency domain are also the same. The clinical medicine usefulness of ballistocardiogram detected by the non-contact technology is approved and the credible evidence for the succeeding signal analysis and the clinical application is provided. Furthermore, the characters of the heartbeat signal detected by our system and the reasons for that are also discussed in detail in our paper.Conference proceedings: ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 02/2007; 2007:2191-4. -
Chapter: Study of the Ballistocardiogram signal in non-contact life detection system based on radar
[show abstract] [hide abstract]
ABSTRACT: In this article, our study of non-contact method viaradar for monitoring the heart and respiratory rates of human subject is reported. The system is constructed which synchronously detects the lectrocardiogram signals by the electrocardiograph and the ballistocardiogram signals by the non-contact life parameter detecting technology. Also, the detected signals are analyzed respectively in the time and frequency domain. The results show that the cycle of the ballistocardiogram is obvious in time domain and that the rhythm of the two kinds of signals keeps consistent. And their characteristic points in frequency domain are also the same. The clinical medicine usefulness of ballistocardiogram detected by the non-contact technology is approved and the credible evidence for the succeeding signal analysis and the clinical application is provided. Furthermore, the characters of the heartbeat signal detected by our system and the reasons for that are also discussed in detail in our paper.12/2007: pages 594-597;
Data provided are for informational purposes only. Although carefully collected, accuracy cannot be guaranteed.
The impact factor represents a rough estimation of the journal's impact factor and does not reflect the actual
current impact factor.
Publisher conditions are provided by RoMEO. Differing provisions from the publisher's actual policy or licence
agreement may be applicable.
Keywords
algorithm
band interference
breath signal
breath signals
coefficients
filtering algorithm
inhibited
radar non-contact life-detecting system
SFA
spectral peaks
standard breath signal
Yule-Walker spectrum