Article

[Study on second filtering algorithm based on tracing the interfering spectral peaks of radar non-contact life-parameter detection system].

Biomedical Engineering Department, Fourth Military Medical University, Xi'an 710032, China.
Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi 09/2006; 23(4):695-8. pp.695-8
Source: PubMed

ABSTRACT To develop a filtering algorithm which could trace the spectral peaks of the interference and which was used to extract the breath signal with the same band interference in radar non-contact life-detecting system, second filtering algorithm was studied. Through first filtering,the probable interfering spectral peaks (ISP) could be detected by Yule-Walker spectrum estimating and could be located by calculating the coefficients of normalized cross-correlation function according to standard breath signal. Thus the breath signal could be extracted through a second filtering. By using the second filtering algorithm (SFA), the same band interfering spectral peaks with breath signal could be recognized and inhibited. So we conclude that the same band mono-ISP could be inhibited by using SFA and breath signals could be effectively extracted.

0 0
 · 
0 Bookmarks
 · 
21 Views
  • Source
    Article: Study of the ballistocardiogram signal in life detection system based on radar.
    [show abstract] [hide abstract]
    ABSTRACT: In this article, our study of non-contact method via radar for monitoring the heart and respiratory rates of human subject is reported. The system is constructed which synchronously detects the electrocardiogram signals by the electrocardiograph and the ballistocardiogram signals by the non-contact life parameter detecting technology. Also, the detected signals are analyzed respectively in the time and frequency domain. The results show that the cycle of the ballistocardiogram is obvious in time domain and that the rhythm of the two kinds of signals keeps consistent. And their characteristic points in frequency domain are also the same. The clinical medicine usefulness of ballistocardiogram detected by the non-contact technology is approved and the credible evidence for the succeeding signal analysis and the clinical application is provided. Furthermore, the characters of the heartbeat signal detected by our system and the reasons for that are also discussed in detail in our paper.
    Conference proceedings: ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference 02/2007; 2007:2191-4.
  • Source
    Chapter: Study of the Ballistocardiogram signal in non-contact life detection system based on radar
    [show abstract] [hide abstract]
    ABSTRACT: In this article, our study of non-contact method viaradar for monitoring the heart and respiratory rates of human subject is reported. The system is constructed which synchronously detects the lectrocardiogram signals by the electrocardiograph and the ballistocardiogram signals by the non-contact life parameter detecting technology. Also, the detected signals are analyzed respectively in the time and frequency domain. The results show that the cycle of the ballistocardiogram is obvious in time domain and that the rhythm of the two kinds of signals keeps consistent. And their characteristic points in frequency domain are also the same. The clinical medicine usefulness of ballistocardiogram detected by the non-contact technology is approved and the credible evidence for the succeeding signal analysis and the clinical application is provided. Furthermore, the characters of the heartbeat signal detected by our system and the reasons for that are also discussed in detail in our paper.
    12/2007: pages 594-597;

Guohua Lu