ABSTRACT Cardiac output is a useful measure of myocardial performance. Standard methods of determining cardiac output are not without risk and can be problematic in children. Arterial pulse wave analysis (PulseCO), a novel, minimally invasive cardiac output determination technique, offers the advantage of continuous monitoring, convenience, and low risk. This technique has not been validated in children. The purpose of this study was to validate PulseCO as an accurate means of noninvasively determining real-time cardiac output in children.
Prospective, single-center evaluation.
Children's hospital.
Any child with a structurally normal heart, undergoing hemodynamic evaluation in the cardiac catheterization laboratory, was included.
A prograde right heart catheterization was performed, and cardiac output was determined using the thermodilution technique, via placement of a pulmonary arterial catheter.
Thermodilution results were compared with continuous real-time cardiac output measurements obtained with the PulseCO system, and they were then analyzed by standard correlation techniques and Bland-Altman analysis. Twenty patients were evaluated with a median age of 10.5 yrs and a median weight of 25 kg. The mean thermodilution cardiac index was 3.3 +/- 0.9 L/min/m, whereas the mean PulseCO cardiac index was 3.1 +/- 0.9 L/min/m. Standard Pearson correlation tests revealed a correlation coefficient of .94 (p < .001). Bland-Altman analysis revealed excellent clinical agreement with a mean difference of 0.19 L/min/m and a precision of 0.28 L/min/m at 2 sd.
Arterial pulse wave analysis by the PulseCO system provides a novel, minimally invasive method of determining real-time cardiac output in children.

1 Follower
 · 
104 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Cardiac output (CO) is the volume of blood pumped out by the heart in 1 minute. Monitoring of CO can guide therapy and improve clinical outcome in critically ill patients and during anesthesia. Although there is increasing research into clinically useful methods of monitoring CO in equine patients, there are limitations to the available methods. There are 4 basic methods of measuring CO: (1) indicator methods, (2) a derivation of the Fick principle, (3) arterial pulse wave analysis, and (4) imaging diagnostic techniques. This article discusses the importance of CO, available technology, and challenges of monitoring CO in equine medicine.
    The Veterinary clinics of North America. Equine practice 04/2013; 29(1):155-67. DOI:10.1016/j.cveq.2012.11.002 · 1.05 Impact Factor
  • Source
  • [Show abstract] [Hide abstract]
    ABSTRACT: To compare cardiovascular and respiratory effects of an inspiratory impedance threshold device (ITD) in dogs before and after induction of acute hemorrhagic shock. Prospective experimental randomized study. Eight healthy adult dogs. Dogs were anesthetized and maintained on spontaneous ventilation. Tidal volume (V(T)), systolic, mean and diastolic arterial blood pressure (SAP, MAP, DAP), central venous pressure (CVP), gastric P(CO2) (GBF) as an indicator of gastric perfusion, cardiac index (CI), systemic vascular resistance (SVR), oxygen delivery (DO(2)), and plasma lactate were monitored. To monitor respiratory compliance (RC) and respiratory resistance (ResR), animals were briefly placed on mechanical ventilation. Dogs were studied under 4 different conditions: (1) baseline (euvolemic state) (MAP > 60 mm Hg) with and without the ITD and (2) acute hemorrhagic shock (hypovolemic state) (target MAP of 40 mm Hg) with and without ITD. These 4 conditions were performed during one anesthetic period, allowing time for stabilization of parameters for each condition. Data were analyzed by ANOVA for repeated measure mixed models. No cardiovascular changes were detected between groups with and without use of ITD during euvolemic states. During acute hemorrhagic hypovolemic state, CI and DO(2) were higher with the ITD (2.9 ± 0.6 L/min/m(2)) and (326.5 ± 86.8 mL/min) compared with no ITD (1.8 ± 0.6 L/min/m(2)) and (191.3 ± 58.1 mL/min), respectively. The use of ITD during hypovolemia also increased SAP and MAP. There was an increase in ResR and decreased RC with the ITD in both euvolemic and hypovolemic states. The use of an ITD in dogs during acute hemorrhagic hypovolemic shock improved cardiovascular parameters but had negative effects on RC and ResR.
    12/2011; 21(6):618-24. DOI:10.1111/j.1476-4431.2011.00692.x