Article

Wide dynamic range detection of bidirectional flow in Doppler optical coherence tomography using a two-dimensional Kasai estimator

Department of Physics, Ryerson University, Toronto, Ontario, Canada
Optics Letters (Impact Factor: 3.18). 02/2007; 32(3):253-5. DOI: 10.1364/OL.32.000253
Source: PubMed

ABSTRACT We demonstrate extended axial flow velocity detection range in a time-domain Doppler optical coherence tomography (DOCT) system using a modified Kasai velocity estimator with computations in both the axial and transverse directions. For a DOCT system with an 8 kHz rapid-scanning optical delay line, bidirectional flow experiments showed a maximum detectable speed of >56 cm/s using the axial Kasai estimator without the occurrence of aliasing, while the transverse Kasai estimator preserved the approximately 7 microm/s minimum detectable velocity to slow flow. By using a combination of transverse Kasai and axial Kasai estimators, the velocity detection dynamic range was over 100 dB. Through a fiber-optic endoscopic catheter, in vivoM-mode transesophageal imaging of the pulsatile blood flow in rat aorta was demonstrated, for what is for the first time to our knowledge, with measured peak systolic blood flow velocity of >1 m/s, while maintaining good sensitivity to detect aortic wall motion at <2 mm/s, using this 2D Kasai technique.

Full-text

Available from: Victor X D Yang, May 05, 2015
0 Followers
 · 
69 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Most of the time, arterial stenoses caused by atherosclerosis, hardening of the artery walls, or buildup of fatty deposits prevent the blood from flowing normally. Blood flow characteristics in the vicinity of a stenosis are therefore very important since the restriction may accelerate fatty deposits and thus quickly clog the artery. Doppler Optical Coherence Tomography (DOCT) is a biomedical technique that allows simultaneous structural imaging and flow monitoring inside biological tissues and materials with spatial resolution at least one order of magnitude better than ultrasound. This study deals with the application of a Near Infrared DOCT system for imaging and monitoring of liquid flow inside a stenosis phantom inserted in a glass tube. For the measurement of the Doppler frequency, we use a numerical method based on the detection of the zero-crossing points of the OCT signal.
    Proceedings of SPIE - The International Society for Optical Engineering 08/2008; DOI:10.1117/12.807215 · 0.20 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: We propose a simple and optimized method for acquiring a wide velocity range of blood flow using Doppler optical microangiography. After characterizing the behavior of the scanner in the fast scan axis, a step-scanning protocol is developed by utilizing repeated A-scans at each step. Multiple velocity range images are obtained by the high-pass filtering and Doppler processing of complex signals between A-scans within each step with different time intervals. A phase variance mask is then employed to segment meaningful Doppler flow signals from noisy phase background. The technique is demonstrated by imaging in vivo mouse brain with skull left intact to provide bidirectional images of cerebral blood flow with high quality and wide velocity range.
    Journal of Biomedical Optics 10/2013; 18(10):106015. DOI:10.1117/1.JBO.18.10.106015 · 2.75 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: We describe preliminary results of high-speed 2-dimensional Doppler OCT measurement using a unique optical frequency domain imaging (OFDI) system. SSG-DBR laser is the light source from which wave number is swept discretely over predetermined absolute values in equal wave number interval with constant output intensity. Multi-sampling at each wave number enables us to reconstruct multiple images by 1 transversal scan, and the dimensional flow image is reconstructed from the phase Doppler shift between 2 successive images. Maximum detectable velocity is restricted by sampling rate, which is higher than A-scan flow has been carried out with this system adopting Kasai velocity estimator. The results predict that the method is valid for stationary flow.
    Proceedings of SPIE - The International Society for Optical Engineering 03/2008; DOI:10.1117/12.764331 · 0.20 Impact Factor