Seven hundred and fifty-nine (759) chances to learn: A 3-year pilot project to analyse transfusion-related near-miss events in the Republic of Ireland

Columbia University, New York, New York, United States
Vox Sanguinis (Impact Factor: 2.8). 05/2007; 92(3):233-41. DOI: 10.1111/j.1423-0410.2006.00885.x
Source: PubMed

ABSTRACT The National Haemovigilance Office has collected and analysed reports on errors associated with transfusion since 2000. A 3-year pilot research project in near-miss event reporting commenced in November 2002.
Near-miss reports from 10 hospital sites were analysed between May 2003 and May 2005. The Medical Event Reporting System for Transfusion Medicine was used to collect and analyse the data. Root cause analysis was used to identify causes of error.
A total of 759 near-miss events were reported. Near misses are occurring 18 times more frequently than adverse events causing harm. Sample collection was found to be the highest risk step in the work process and was the first site of error in 468 (62%) events. Of these, 13 (3%) involved samples taken from the wrong patient. Medical staff were frequently involved in error. The general wards and emergency department were identified as high-risk clinical areas, in addition, 78 (10%) events occurred within the transfusion laboratory. Three specific human and two system failures were shown to have been associated with the errors identified in this study.
This study confirms that near-miss events occur far more frequently than adverse events causing harm. Collecting near-miss data is an effective means of highlighting human and system failures associated with transfusion that may otherwise go unnoticed. These data can be used to identify areas where resources need to be targeted in order to prevent future harm to patients, improving the overall safety of transfusion.

Download full-text


Available from: Barbara Rabin Fastman, Sep 27, 2015
1 Follower
28 Reads
  • [Show abstract] [Hide abstract]
    ABSTRACT: In blood transfusion procedures, it is necessary to guarantee that each patient actually receives the blood unit which has been assigned to him, so that mistransfusions are avoided. For this reason, before starting the administration, a cross-check involving the patient and the trasfusion unit codes must be carried out at bedside. To perform these tests in a safe and fast way, several electronic solutions based on barcode labels and RFID tags have been adopted in the last few years. However, most reliable results are still obtained by means of barrier systems, i.e. mechanical devices that prevent the use of units until the cross-check is positive. In this paper, we present a microcontroller-based barrier system which can easily be integrated with common barcode/RFID-based solutions, so that an even higher safety degree is achievable together with simple and fast utilization. The system provides blood unit temperature monitoring and event logging capabilities, can be controlled by means of a wireless connection, and is powered by a high capacity Li-ion battery, which ensures long operating cycles. Moreover, it features a simple human interface, and appears rather small and light, thus resulting definitely suitable for the clinical settings. Once implemented, the system has been successfully validated by means of a Lab VIEW interface emulating a typical medical facility set-up. Currently, two on-site applications show a remarkable safety and speed improvement in performing cross-check procedures.
  • [Show abstract] [Hide abstract]
    ABSTRACT: Space division multiple access (SDMA) is emerging as a promising multiple access technique to provide a considerable increase in capacity and quality of many wireless systems. To implement SDMA optimally, a smart antenna system, composed of a multiport antenna with substantial port-to-port isolation and a digital signal processor with an adaptive algorithm, is required. This paper describes the design of a compact multiport antenna that can be integrated with a transmitter or receiver to yield a smart antenna system for the indoor PCS base station. The electrical performances of the antenna are presented. The multiport antenna has a novel structure with twelve elemental antennas. By applying both polarization and pattern diversity schemes to the same antenna, antenna elements can be located in close proximity, within a radius of half wavelength at the design frequency, to allow a significant reduction in antenna size while maintaining the low mutual coupling. The experimental results indicate that the multiport antenna features a good isolation between elements and a practical input impedance for each elemental antenna over a wide bandwidth
    Antennas and Propagation Society International Symposium, 1999. IEEE; 09/1999
  • [Show abstract] [Hide abstract]
    ABSTRACT: A near-miss event is defined as an event that could have resulted in an injury, fatality, or property damage if it had not been prevented. Analysis of near-miss events could be an efficient method in the study of adverse events. Reporting of near-misses has many benefits in the study of adverse events since near-misses occur more frequently than adverse events. In addition, as they have no consequences, fear that the professionals involved would have to report them is less. However, up to now, this method has been slow to develop. We present two clinical cases that help to understand the usefulness of the near-miss reporting system.
    Medicina Intensiva 03/2008; 32(3):143–146. DOI:10.1016/S0210-5691(08)70924-0 · 1.34 Impact Factor
Show more