The integration of chitosan-coated titanium in bone: an in vivo study in rabbits.

Joel D Bumgardner, Betsy M Chesnutt, Youling Yuan, Yunzhi Yang, Mark Appleford, Sunho Oh, Ronald McLaughlin, Steven H Elder, Joo L Ong

Joint Biomedical Engineering Program, University of Memphis, University of Tennessee Health Science Center-Memphis, Memphis, TN 38152, USA.

Implant Dentistry (impact factor: 1.51). 04/2007; 16(1):66-79. DOI: 10.1097/ID.0b013e3180312011

Journal Article

Abstract

PROCEDURE: Much research is directed at surface modifications to enhance osseointegration of implants. A new potential coating is the biopolymer, chitosan, the deacetylated derivative of the natural polysaccharide, chitin. Chitosan is biocompatible, degradable, nontoxic, and exhibits osteogenic properties. The aim of this research was to investigate the hypothesis that chitosan-coated titanium supports bone formation and osseointegration. MATERIALS AND METHODS: Chitosan (1 wt% of 92.3% deacetylated chitosan in 1% acetic acid) was solution cast and bonded to rough ground titanium pins (2-mm diameterx4-mm long) via silane reactions. Calcium phosphate sputter-coated titanium and uncoated titanium pins were used as controls. Two chitosan-coated pins, and 1 each of calcium phosphate coated and uncoated pins were implanted unilaterally in the tibia of 16 adult male New Zealand white rabbits. At 2, 4, 8, and 12 weeks, undecalcified sections were histologically evaluated for healing and bone formation. RESULTS: Histological evaluations of tissues in contact with the chitosan-coated pins indicated minimal inflammatory response and a typical healing sequence of fibrous, woven bone formation, followed by development of lamellar bone. These observations were similar to those for tissues interfacing the control calcium phosphate-coated and uncoated titanium implants. Quantitative comparisons of the bone-implant interface were not possible since 31% of the implants migrated into the tibial marrow space after implantation due to insufficient cortical bone thickness to hold pins in place during healing. CONCLUSION: These data support the hypothesis that chitosan-coatings are able to develop a close bony apposition or the osseointegration of dental/craniofacial and orthopedic implants.

Source: PubMed

Comments on this publication

ResearchGate members can add comments. Sign up now and post your comment!

Similar publications

Science & Research Jobs

Keywords

1% acetic acid
 
92.3% deacetylated chitosan
 
bone formation
 
bone-implant interface
 
Calcium phosphate sputter-coated titanium
 
chitosan-coated pins
 
chitosan-coated titanium
 
control calcium phosphate-coated
 
insufficient cortical bone thickness
 
lamellar bone
 
natural polysaccharide
 
orthopedic implants
 
Quantitative comparisons
 
rough ground titanium pins
 
surface modifications
 
tissues interfacing
 
uncoated pins
 
uncoated titanium implants
 
uncoated titanium pins
 
woven bone formation