Article

Anti-dsDNA antibody assay: high specificity and sensitivity with a filtration radioassay in comparison to low specificity with the standard ELISA.

Barbara Davis Center for Childhood Diabetes and the Division of Rheumatology, School of Medicine, University of Colorado Health Sciences Center, Denver, Colorado, USA.
The Journal of Rheumatology (Impact Factor: 3.17). 05/2007; 34(4):734-9.
Source: PubMed

ABSTRACT To evaluate whether a new fluid-phase filtration radioassay possesses both high sensitivity and specificity compared with the currently used ELISA and Farr assays.
Sequential sera (25 samples) from 9 patients with systemic lupus erythematosus (SLE), sera from 20 patients with SLE possessing anti-dsDNA antibodies by the Crithidia assay, 75 patients with rheumatoid arthritis possessing rheumatoid factors, 50 healthy control subjects, 767 from patients with type 1 diabetes, and a commercial standard serum sample were tested for anti-dsDNA antibodies with the 3 different assays.
Of serial dilutions of a standard anti-dsDNA antibody sample, only the highest positive sample (50 IU/ml) in the ELISA and the highest 2 positive samples (50 and 25 IU/ml) in the Farr assay were above the normal range. In contrast, all dilutions (to 2.5 IU/ml) of the standard anti-dsDNA antibody sample were above the normal range in the filtration radioassay. Using the values of 50 healthy control subjects in each assay to define the normal range, all 25 sequential sera from 9 patients with SLE were positive. In addition, 20/20 of the SLE individual sera, 2/75 (2.7%) of the RA sera, and 12/767 (1.6%) of the diabetes sera were positive (signal above normal range) in the filtration radioassay. The SLE sera were further examined in 2 additional assays, ELISA and Farr assay, and both assays were less sensitive and specific compared with the filtration radioassay.
The fluid-phase filtration radioassay demonstrated high sensitivity and specificity for the detection of anti-dsDNA antibodies in SLE, with the standard ELISA exhibiting lower specificity. We suggest that testing for anti-dsDNA antibodies can be improved using a fluid-phase filtration radioassay in comparison to commercial assays.

0 Followers
 · 
104 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The predominant autoantibody assays employed in basic immunologic studies are variations of solid-phase assays where autoantigens are bound to 96-well plates. Though the assay format is convenient and often appropriate for studies of induced immune responses in inbred strains of mice, we will argue that this assay format usually, but not always, leads in clinical medicine to what should be unacceptable false positive results as well as lower sensitivity compared to the current generation of high throughput fluid-phase radioassays. Utilizing simple in vitro transcription and translation labeling of autoantigens, it is now possible to rapidly create fluid-phase radioassays for most (but not all) autoantigens, thereby allowing direct comparison between the different assay formats. In addition, adding a fluid-phase competition step to both solid-phase ELISA assays and even fluid-phase radioassays can enhance specificity. Development in a field of such assays with excellent specificity and sensitivity (e.g. studies of type 1A diabetes) is fostered by Societies sponsoring workshops where blinded samples are evaluated with "competing" assay formats for sensitivity, specificity, and reproducibility.
    Clinical Immunology 12/2007; 125(2):120-6. DOI:10.1016/j.clim.2007.08.005 · 3.99 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Measurement of transglutaminase autoantibodies (TGAA) is considered to be the most efficient single serologic test for celiac disease (CD) by the American Gastroenterological Association Institute. We hypothesized that a large international collaborative effort toward improving and standardizing TGAA measurement is both feasible and necessary. The primary aim of this workshop is to compare TGAA assays among various research and clinical laboratories to examine assay concordance and improve (and eventually standardize) the TGAA assay. A total of 20 laboratories (5 commercial laboratories, 15 research and clinical laboratories) participated that included enzyme-linked immunosorbent assay (ELISA) and radiobinding assays. A total of 150 serum samples were distributed to each laboratory, with each laboratory receiving an equal aliquot that was coded and blinded, composed of 100 healthy control sera and 50 CD sera. Laboratory sensitivity ranged from 69% to 93% and specificity ranged from 96% to 100%. By receiver operator characteristic analysis, the area under the curve (C index) ranged from 0.9488 to 0.9904. When analyzing for linear correlation, r-squared was as high as 0.8882 but as low as 0.4244 for the celiac samples between different laboratories performing ELISA. This transglutaminase autoantibody workshop allows for larger-scale international participation for the purposes of improving and eventually standardizing the TGAA assay with subsequent workshops.
    The American Journal of Gastroenterology 02/2009; 104(1):154-63. DOI:10.1038/ajg.2008.8 · 9.21 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The key feature of heparin-induced thrombocytopenia (HIT) is the production of antibodies (Ab) against the platelet factor 4 (PF4)/heparin complex. These Ab are directed against neoepitopes of the PF4 tetramer, which are induced by the complex formation with heparin. To study this humoral immune response in greater detail, either in a murine immunization model or in human blood samples, reliable and specific immune assays to detect specifically Ab against the PF4/heparin complexes, but not PF4 alone are required. We established fluid-phase enzyme-immunoassays in which the soluble biotinylated antigen, PF4/heparin, is firstly captured by specific Ab, and secondly directly detected with enzyme-conjugated streptavidin. The use of this fluid-phase principle allowed a higher specificity than the traditional solid-phase enzyme-immunoassays in terms of Ab binding to murine PF4/heparin compared to murine PF4 alone. This fluid-phase approach applied to the detection of specific murine PF4/heparin Ab-secreting cells (ASC) identified the spleen as the main lymphatic organ that contributes to the PF4/heparin Ab response in mice. IgG ASC specific for PF4/heparin are very transiently detectable in mice, which might explain why anti-PF4/heparin IgG Ab typically disappear within 100days in humans. Furthermore, this fluid-phase approach was successfully transferred to detect human PF4/heparin-specific Ab. The fluid-phase principle for the specific detection of anti-PF4/heparin IgG and IgM Ab enables new and improved assays for HIT research in men and mice. At least in mice PF4/heparin antibodies are produced by transient B cells.
    Thrombosis Research 04/2014; 134(1). DOI:10.1016/j.thromres.2014.04.014 · 2.43 Impact Factor

Preview

Download
1 Download
Available from