Article

A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: Fixed dental prostheses

Clinic for Fixed and Removable Prosthodontics and Dental Material Science, University of Zurich, Zurich, Switzerland.
Clinical Oral Implants Research (Impact Factor: 3.12). 06/2007; 18 Suppl 3(s3):86-96. DOI: 10.1111/j.1600-0501.2007.01468.x
Source: PubMed

ABSTRACT The objective of this systematic review was to assess the 5-year survival rates and incidences of complications of all-ceramic fixed dental prostheses (FDPs) and to compare them with those of metal-ceramic FDPs.
An electronic MEDLINE and Dental Global Publication Research System search complemented by manual searching was conducted to identify prospective and retrospective cohort studies on all-ceramic and metal-ceramic reconstructions with a mean follow-up time of at least 3 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by three reviewers. Failure rates were analyzed using standard and random-effects Poisson regression models to obtain summary estimates of 5-year survival proportions.
The search provided 3473 titles for single crowns and FDPs and resulted in 100 abstracts for all-ceramic FDPs. Full-text analysis was performed for 39 articles, resulting in nine studies of ceramic FDPs that met the inclusion criteria. The data on survival and complication rates of metal-ceramic FDPs were obtained from a previous systematic review of Tan et al. (2004) and the updated version from the same authors (Pjetursson et al. 2007). In Poisson regression meta-analysis, the 5-year survival of metal-ceramic FDPs was significantly (P<0.0001) higher with 94.4% [95 confidence interval (CI): 91.1-96.5%] than the survival of all-ceramic FDPs, being 88.6% (95 CI: 78.3-94.2%). The frequencies of material fractures (framework and veneering material) were significantly (P<0.0001) higher for all-ceramic FDPs (6.5% and 13.6%) compared with those of metal-ceramic FDPs (1.6% and 2.9%). Other technical complications like loss of retention and biological complications like caries and loss of pulp vitality were similar for the two types of reconstructions over the 5-year observation period.
Based on the present systematic review of all-ceramic FDPs, significantly lower survival rates at 5 years were seen compared with metal-ceramic FDPs. The most frequent reason for failure of FDPs made out of glass-ceramics or glass-infiltrated ceramics was fracture of the reconstruction (framework and veneering ceramic). However, when zirconia was used as framework material, the reasons for failure were primarily biological and technical complications other than framework fracture.

3 Followers
 · 
141 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Abstract Objective. The clinical survival rates of the adhesive restorations are limited due to the deterioration of resin-dentin bonds over time, partly due to the endogenous enzymatic activity of dentin. Recently, benzalkonium chloride (BAC) has been shown to effectively inhibit endogenous protease activity of dentin. This study evaluated the effect of different concentrations of benzalkonium chloride (BAC) on the degree of conversion (DC), vickers hardness (VH), setting time (ST) and biaxial flexural strength (FS) of two self-adhesive resin luting cements (RC). Methods. Two RC SpeedCEM (Ivoclar-Vivadent) and BisCem (Bisco) were modified by addition of 0.1, 0.5, 1, 1.5, 2 wt% BAC. The luting cements without the addition of BAC served as control. The DC (FT-IR/ATR from the bottom of the resin disc), vickers hardness (from top and bottom of the light-cured specimen), setting time (ISO 4049) and biaxial flexural strength (0.6 × 6 mm discs) of the specimens were tested. Data were analyzed using ANOVA and Tukeys HSD. Results. DC results were in the range of 70-80%, with some significant changes in BisCem (p < 0.05). VH values of both materials increased significantly compared to control, with no significant change as the BAC percentage increases. BAC addition influenced the ST differently for both materials. For BisCem, a gradual decrease (p < 0.05) was observed whereas, for SpeedCEM, a gradual increase was observed until 1% BAC (p < 0.05). For FS values, a gradual decrease was observed for both materials with increased amounts of BAC (p < 0.05), compared to the control group. Conclusions. BAC addition of up to 1% seems to be acceptable considering the properties tested. Clinical significance. Incorporation of benzalkonium chloride to self-adhesive resin luting cements during the mixing procedure does not significantly affect the degree of conversion or flexural strength of the luting agent and may be a good option to improve the durability of adhesive interface.
    Acta odontologica Scandinavica 05/2014; 72(8):1-8. DOI:10.3109/00016357.2014.913307 · 1.31 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The objective of the present work was to study the curvature of very thinly, veneered Y-TZP discs of different framework thicknesses submitted to different firing times. Fifteen 20-mm-wide Y-TZP discs were produced in three different thicknesses: 0.75, 1, 1.5mm. One disc from each group was left unveneered while the others were layered with a 0.1mm veneering ceramic layer. All discs underwent five firing cycles for a total cumulative firing time of 30min, 1, 2, 5 and 10h at 900°C. The curvature profile was measured using a profilometer after the veneering process and after each firing cycle respectively. A fitted curve was then used to estimate the, curvature radius. The coefficient of thermal expansion (CTE) measurements were taken on veneering, ceramic and Y-TZP beam samples that underwent the same firing schedule. Those data were used to calculate the curvature generated by CTE variations over firing time. All bilayered samples exhibited a curvature that increased over firing time inversely to framework thickness. However non-veneered samples did not exhibit any curvature modification. The results of the present study reveal that even a very thin veneer layer (0.1mm) can induce a significant curvature of Y-TZP discs. The dilatometric results showed that Tg and CTE, variations are not sufficient to explain this curvature. A chemical-induced zirconia volume, augmentation located at the framework sub-surface near the interface could explain the sample, curvature and its increase with firing time.
    Dental materials: official publication of the Academy of Dental Materials 12/2013; DOI:10.1016/j.dental.2013.11.009 · 4.16 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: With the Internet facilitating access to vast amounts of free information, dental practitioners face providing treatment for an increasingly informed public. However, the available content is not filtered, and it can be difficult for patients to discriminate between research-informed evidence and "glamorised" material of dubious origin. Patients reasonably expect a return for their investment and want to know how long their treatment will last. Clinicians have an obligation to inform their patients so that they can make reasoned decisions about treatment options. Longevity data are also informative for health agencies setting service schedules for publicly funded treatment, and for determining settlements by insurers such as ACC. Historically, much of the prosthodontic treatment performed in practice has relied heavily on dogma, low-level anecdotal evidence, and clinical case reports. This paper considers the literature on fixed and removable prosthodontic restorations and provides a critical review which can be used practically as the basis for informing patients, and to assist decision-makers in making fair and appropriate judgements.
    The New Zealand dental journal 09/2013; 109(3):98-105.