Large scan field, high spatial resolution flat-panel detector based volumetric CT of the whole human skull base and for maxillofacial imaging.

S H Bartling, O Majdani, R Gupta, T Rodt, C Dullin, P F Fitzgerald, H Becker

Department of Neuroradiology, OE 8210, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany.

Journal Article: Dentomaxillofacial Radiology (impact factor: 1.23). 10/2007; 36(6):317-27. DOI: 10.1259/dmfr/19164138

Abstract

OBJECTIVES: To assess the feasibility of flat-panel detector based volumetric CT (fpVCT) scanning of the whole human skull base and maxillofacial region, which has thus far only been demonstrated on small, excised specimens. Flat-panel detectors offer more favourable imaging properties than image intensifiers. It is therefore likely that they will replace them in cone-beam CT scanners that are currently used to scan parts of the skull base and maxillofacial region. Furthermore, the resolution of current CT imaging limits diagnosis, surgical planning and intraoperative navigation within these regions. fpVCT might overcome these limitations because it offers higher resolution of high contrast structures than current CT. METHODS: Three embalmed cadaver heads were scanned in two scanners: an experimental fpVCT that offers a scan field large enough for a whole human head, and in a current multislice CT (MSCT). 28 structures were compared. RESULTS: Both scanners produced bone images of diagnostic quality. Small high contrast structures such as parts of the ossicular chain and thin bony laminas were better delineated in fpVCT than in MSCT. fpVCT of maxillofacial region and skull base was rated superior to MSCT (P=0.002) as found in this limited, experimental study. CONCLUSIONS: High spatial resolution fpVCT scanning of both regions in a whole human head is feasible and might be slightly superior to MSCT. fpVCT could improve diagnostic accuracy in selected cases, as well as surgical planning and intraoperative navigation accuracy.

Source: PubMed

Comments on this publication

ResearchGate members can add comments. Sign up now and post your comment!

Similar publications

Available from:

Resources

Science & Research Jobs

Keywords

cone-beam CT scanners
 
contrast structures
 
current CT
 
current CT imaging limits diagnosis
 
current multislice CT
 
embalmed cadaver heads
 
excised specimens
 
experimental fpVCT
 
experimental study
 
favourable imaging properties
 
fpVCT
 
image intensifiers
 
intraoperative navigation accuracy
 
maxillofacial region
 
MSCT
 
ossicular chain
 
spatial resolution fpVCT scanning
 
volumetric CT
 
whole human head
 
whole human skull base