Article

Decoding a new neural machine interface for control of artificial limbs.

Neural Engineering Center for Artificial Limbs, Rehabilitation Institute of Chicago, IL, USA.
Journal of Neurophysiology (Impact Factor: 3.04). 12/2007; 98(5):2974-82. DOI: 10.1152/jn.00178.2007
Source: PubMed

ABSTRACT An analysis of the motor control information content made available with a neural-machine interface (NMI) in four subjects is presented in this study. We have developed a novel NMI-called targeted muscle reinnervation (TMR)-to improve the function of artificial arms for amputees. TMR involves transferring the residual amputated nerves to nonfunctional muscles in amputees. The reinnervated muscles act as biological amplifiers of motor commands in the amputated nerves and the surface electromyogram (EMG) can be used to enhance control of a robotic arm. Although initial clinical success with TMR has been promising, the number of degrees of freedom of the robotic arm that can be controlled has been limited by the number of reinnervated muscle sites. In this study we assess how much control information can be extracted from reinnervated muscles using high-density surface EMG electrode arrays to record surface EMG signals over the reinnervated muscles. We then applied pattern classification techniques to the surface EMG signals. High accuracy was achieved in the classification of 16 intended arm, hand, and finger/thumb movements. Preliminary analyses of the required number of EMG channels and computational demands demonstrate clinical feasibility of these methods. This study indicates that TMR combined with pattern-recognition techniques has the potential to further improve the function of prosthetic limbs. In addition, the results demonstrate that the central motor control system is capable of eliciting complex efferent commands for a missing limb, in the absence of peripheral feedback and without retraining of the pathways involved.

1 Bookmark
 · 
112 Views
  • Source
    Frontiers in Computational Neuroscience 01/2015; 9(27). · 2.23 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG) is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1) the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2) the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1) it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2) hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported.
    PLoS ONE 10/2014; 9(10):e109943. · 3.53 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Wearable electrodes made of silver nanowires (AgNWs) have demonstrated great potential for sensing a variety of physical and physiological signals. This paper aimed to study the feasibility of AgNWs electrodes for measuring surface electromyographic (sEMG) signals. One human subject was recruited and instructed to perform wrist extension repetitively or to produce no movement in the experiment. sEMG signals were collected from the right extensor digitorum communis of the human subject by an AgNWs electrode and a commercially available Ag/AgCl wet sEMG electrode, separately. The quality of recorded sEMG in time and frequency domains was compared between the two types of electrodes. The results showed that the sEMG signals recorded by the AgNW electrode were comparable with that by the Ag/AgCl electrode. Since the dry AgNWs electrodes are flexible, wearable, and potentially robust for daily use, novel AgNW-based EMG electrodes are promising for many biomedical applications, such as myoelectric control of artificial limbs.
    08/2014; 2014:1674-7.

Full-text (2 Sources)

Download
43 Downloads
Available from
Jun 3, 2014