Emergency Retrieval of a G2 Filter after Complete Migration into the Right Ventricle

Division of Vascular and Interventional Radiology, Department of Radiology Stanford University Medical Center, 300 Pasteur Dr, H-3651, Stanford, CA 94305-5642, USA.
Journal of Vascular and Interventional Radiology (Impact Factor: 2.41). 10/2007; 18(9):1177-82. DOI: 10.1016/j.jvir.2007.06.006
Source: PubMed


A G2 inferior vena cava filter migrated completely into the right ventricle, resulting in chest pain, ventricular tachycardia, and hypotension in a 63-year-old man. Due to the filter's position, the patient was at high risk for further life-threatening cardiopulmonary complications. Percutaneous filter retrieval was successfully performed as a less-invasive alternative to open cardiothoracic surgery.

1 Follower
6 Reads
  • Source
    Conference Paper: Some new EC/AUED codes.
    [Show abstract] [Hide abstract]
    ABSTRACT: A novel construction that differs from the traditional way of constructing systematic EC/AUED/(error-correcting/all unidirectional error-detecting) codes is presented. The usual method is to take a systematic t -error-correcting code and then append a tail so that the code can detect more than t errors when they are unidirectional. In the authors' construction, the t -error-correcting code is modified in such a way that the weight distribution of the original code is reduced. The authors then have to add a smaller tail. Frequently they have less redundancy than the best available systematic t -EC/AUED codes
    Proceedings of the Nineteenth International Symposium on Fault-Tolerant Computing, FTCS 1989, Chicago, IL, USA, 21-23 June, 1989; 01/1989
  • [Show abstract] [Hide abstract]
    ABSTRACT: A novel algorithm for compacting a VLSI chip on the macrocell level is presented. Compared to previous algorithms, the technique can handle larger designs, produces higher-quality output, and reduces designer intervention as much as possible. Jogs are automatically introduced in the connecting wires to achieve the needed flexibility for placing cells into optimal positions
    Computer Design: VLSI in Computers and Processors, 1989. ICCD '89. Proceedings., 1989 IEEE International Conference on; 11/1989
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The temporal and spectral response of bulk GaAs Fabry-Perot microcavities have been investigated in the subpicosecond regime at room temperature. Time resolved reflectivity measurements show a strong reshaping of a Gaussian fs-pulse after reflection from a microcavity caused by group velocity dispersion. The pulse distortion agrees fairly well with model calculations using Fourier transform analysis. Time integrated degenerate four-wave mixing experiments show that response times of the cavity as short as 300 fs were achieved
    Semiconducting and Semi-Insulating Materials Conference, 1996. IEEE; 01/1996
Show more