Clearance of levofloxacin by an in vitro model of continuous venovenous hemodialysis (CVVHD).

Institute of Clinical Pharmacology, University of Rostock, Rostock, Germany.
The International journal of artificial organs (impact factor: 1.86). 10/2007; 30(10):889-95. pp.889-95
Source: PubMed

ABSTRACT Information about the elimination and the adequate dosing of levofloxacin during renal replacement therapy is scarce. The aim of this study was to characterize in vitro the elimination of levofloxacin during continuous venovenous hemodialysis (CVVHD) and to investigate whether the CVVHD clearances of creatinine and urea are correlated with the levofloxacin clearance in order to facilitate dosage adjustments. An in vitro model of CVVHD was established using five dialyzer membranes at varying dialysate flow rates applied in the clinical setting (8, 16, 25, 33 and 41 ml/min). Plasma and dialysate samples were drawn for determination of levofloxacin, creatinine and urea concentrations to evaluate clearances by CVVHD. During CVVHD, the clearance of levofloxacin varied between 9.02 and 33.30 ml/min, depending on the chosen setup. Positive correlations (p<0.001) were received for: dialysate flow rate (QD) and creatinine/ urea clearances (R(2)>0.93); QD and levofloxacin clearance (R(2) 0.59-0.71); levofloxacin and creatinine clearance (R(2) 0.69-0.75); and levofloxacin and urea clearance (R(2) 0.56-0.75) as well. When dosing critically ill patients, therefore, extracorporeal as well as total clearance of levofloxacin should be considered.

0 0
 · 
0 Bookmarks
 · 
13 Views

Keywords

adequate dosing
 
chosen setup
 
clearances
 
continuous venovenous hemodialysis
 
creatinine
 
creatinine clearance
 
creatinine/ urea clearances
 
CVVHD clearances
 
dialysate flow rate
 
dialysate samples
 
dialyzer membranes
 
dosage adjustments
 
levofloxacin clearance
 
levofloxacin varied
 
Positive correlations
 
renal replacement therapy
 
total clearance
 
varying dialysate flow rates
 
vitro
 
vitro model
 

S Siewert