A method for vector displacement estimation with ultrasound images and its application for thy-roid nodular disease. Med Image Anal

CREATIS-LRMN, CNRS UMR 5520, INSERM U 630, INSA-Lyon, F-69621, France.
Medical image analysis (Impact Factor: 3.68). 07/2008; 12(3):259-74. DOI: 10.1016/j.media.2007.10.007
Source: PubMed

ABSTRACT Ultrasound elastography is a promising imaging technique that can assist in diagnosis of thyroid cancer. However, the complexity of the tissue movements under freehand compression requires the use of a parametric displacement model and a specific estimation method adapted to sub-pixel motion. Therefore, the aim of this study was to develop a motion estimation method for ultrasound elastography and test its performances compared to a classical block matching technique. The proposed method, referred to as Bilinear Deformable Block Matching (BDBM), uses a bilinear model with eight parameters for controlling the local mesh deformation. In addition, a technique of motion initialization based on a triangle scan of the images adapted to ultrasound elastography is proposed. The BDBM method includes an iterative multi-scale process. This iterative approach is shown to decrease the absolute error of the displacement estimation by a factor of 1.4 when passing from 1 to 2 iterations. The method was tested on simulated images and the results show that absolute displacement estimation error was reduced by a factor of 4 compared to classical block matching. We applied the BDBM method on three experimental sets of data. In the first data set, a phantom designed for ultrasound elastography was used. The two other sets of data involve the thyroid gland and were acquired using freehand tissue compression by ultrasound probe of a clinical ultrasound scanner modified for research. A similarity measurement based on local cross-correlation shows that, for experimental data, the BDBM method outperforms the usual block matching.

0 Followers
 · 
211 Views
  • Source
    • "Improved physical examination detection has been reached for increasingly bigger nodules but still only 48.2% for nodules larger than 2 cm could be detected. Currently, various methods for automatic detection and investigation of the thyroid nodules in the US images were proposed [10] [11] [12] [13]. All methods are based on the analysis of an optimal ROI cropped from the US image. "
    [Show abstract] [Hide abstract]
    ABSTRACT: Statistical approach is a valuable way to describe texture primitives. The aim of this study is to design and implement a classifier framework to automatically identify the thyroid nodules from ultrasound images. Using rigorous mathematical foundations, this article focuses on developing a discriminative texture analysis method based on texture variations corresponding to four biological areas (normal thyroid, thyroid nodule, subcutaneous tissues, and trachea). Our research follows three steps: automatic extraction of the most discriminative first-order statistical texture features, building a classifier that automatically optimizes and selects the valuable features, and correlating significant texture parameters with the four biological areas of interest based on pixel classification and location characteristics. Twenty ultrasound images of normal thyroid and 20 that present thyroid nodules were used. The analysis involves both the whole thyroid ultrasound images and the region of interests (ROIs). The proposed system and the classification results are validated using the receiver operating characteristics which give a better overall view of the classification performance of methods. It is found that the proposed approach is capable of identifying thyroid nodules with a correct classification rate of 83 % when whole image is analyzed and with a percent of 91 % when the ROIs are analyzed.
    Journal of Digital Imaging 05/2012; 26(1). DOI:10.1007/s10278-012-9475-5 · 1.20 Impact Factor
  • Source
    • "The block-matching criterion is determined by minimizing the sum-of-squared difference. Pixel displacement within the ROI is then calculated based on a bilinear model, where the unknown parameters can be determined from the calculated displacement of the ROI corners [21]. Fig. 5 demonstrates a final motion estimation for one block between two imaging frames in which the needle advanced 1.5 mm. 2) Algorithm Verification: The speckle-tracking algorithm performance was verified by simulating an ultrasound image of known displacement, using the " Field 2 " freeware [23]–[25], which enables ultrasound image simulations. "
    [Show abstract] [Hide abstract]
    ABSTRACT: The success rate of medical procedures involving needle insertion is often directly related to needle placement accuracy. Due to inherent limitations of commonly used freehand needle placement techniques, there is a need for a system providing for controlled needle steering for procedures that demand high positional accuracy. This paper describes a robotic system developed for flexible needle steering inside soft tissues under real-time ultrasound imaging. An inverse kinematics algorithm based on a virtual spring model is applied to calculate needle base manipulations required for the tip to follow a curved trajectory while avoiding physiological obstacles. The needle tip position is derived from ultrasound images and is used in calculations to minimize the tracking error, enabling a closed-loop needle insertion. In addition, as tissue stiffness is a necessary input to the control algorithm, a novel method to classify tissue stiffness from localized tissue displacements is proposed and shown to successfully distinguish between soft and stiff tissue. The system performance was experimentally verified by robotic manipulation of the needle base inside a phantom with layers of varying stiffnesses. The closed-loop experiment with updated tissue stiffness parameters demonstrated a needle-tip tracking error of ~ 1 mm and proved to be significantly more accurate than the freehand method.
    IEEE Transactions on Biomedical Engineering 05/2010; 57(4-57):799 - 805. DOI:10.1109/TBME.2009.2030169 · 2.23 Impact Factor
  • Source
    • "Modèle déformable multi-blocs : l'emploi conjugué de plusieurs blocs de recherche autour d'un modèle déformable augmente la robustesse du block matching [15] [16]. Dans ce travail, nous utilisons un modèle composé de cinq blocs partiellement recouverts alignés longitudinalement (Figure 3). "
    [Show abstract] [Hide abstract]
    ABSTRACT: Les maladies cardiovasculaires représentent la première cause de mortalité dans les pays industrialisés. Il est donc important d'effectuer un diagnostic précoce, préférentiellement de manière non invasive, pour traiter une vaste population. Les propriétés mécaniques des artères, notamment la carotide, sont affectées par l'athérosclérose, et sont considérées comme de bons indicateurs d'une manifestation pathologique précoce. Le comportement de la paroi de la carotide au long du cycle cardiaque présente plusieurs phénomènes particuliers dont l'analyse par imagerie ultrasonore permet de remonter aux causes pathologiques. Ce travail s'intéresse à l'étude conjointe de ces paramètres mécaniques au long d'une séquence d'images échographiques. Nous considérons principalement la force de cisaillement longitudinale exercée par le sang sur la paroi, l'onde de pouls causée par l'effet de dilatation-contraction radiale, et la compression élastique des couches de l'artère. Notre approche trouve son originalité dans le fait qu'elle prend en compte conjointement plusieurs paramètres mécaniques obtenus in vivo et se destine prioritairement à une application clinique pratique pouvant fournir une aide au diagnostic. Les séquences d'images ultrasonores traitées sont des coupes longitudinales de la carotide commune acquises avec un échographe clinique. Nous effectuons une analyse spatio-temporelle en considérant que le mouvement de chaque point de la paroi est continu dans le temps et dans l'espace. Le déplacement est estimé précisément grâce à un algorithme de mise en correspondance de blocs déformables. En fonction des paramètres à estimer pour l'étude du déplacement des couches de la carotide, les tailles de blocs et de noyau utilisés sont déterminées de manière optimale. Un comportement pathologique peut finalement être détecté à partir des paramètres extraits en comparaison de la déformation attendue d'une artère saine.
Show more