Article

US imaging of tumor angiogenesis with microbubbles targeted to vascular endothelial growth factor receptor type 2 in mice

Department of Radiology and Bio-X Program, Stanford University School of Medicine, James H. Clark Center, 318 Campus Dr, East Wing, 1st Floor, Stanford, CA 94305-5427, USA.
Radiology (Impact Factor: 6.21). 02/2008; 246(2):508-18. DOI: 10.1148/radiol.2462070536
Source: PubMed

ABSTRACT To prospectively evaluate contrast material-enhanced ultrasonography (US) with microbubbles targeted to vascular endothelial growth factor receptor type 2 (VEGFR2) for imaging tumor angiogenesis in two murine tumor models.
Animal protocols were approved by the Institutional Administrative Panel on Laboratory Animal Care. A US contrast agent, consisting of encapsulated gaseous microbubbles, was developed specifically to bind to VEGFR2 (by using anti-VEGFR2 antibodies and biotin-streptavidin interaction) which is up-regulated on endothelial cells of tumor blood vessels. VEGFR2-targeted microbubbles (MB(V)), control microbubbles (MB(C)), and nonlabeled microbubbles (MB(N)) were tested for binding specificity on cells expressing VEGFR2 (mouse angiosarcoma SVR cells) and control cells (mouse skeletal myoblast C2C12 cells). Expression of mouse VEGFR2 in culture cells was tested with immunocytochemical and Western blot analysis. Contrast-enhanced US imaging with MB(V) and MB(C) was performed in 28 tumor-bearing nude mice (mouse angiosarcoma, n = 18; rat malignant glioma, n = 10). Differences were calculated by using analysis of variance.
In cell culture, adherence of MB(V) on SVR cells (2.1 microbubbles per SVR cell) was significantly higher than adherence of control microbubbles (0.01-0.10 microbubble per SVR cell; P < .001) and significantly more MB(V) attached to SVR cells than to C2C12 cells (0.15 microbubble per C2C12 cell; P < .001). In vivo, contrast-enhanced US imaging showed significantly higher average video intensity when using MB(V) compared with MB(C) for angiosarcoma and malignant glioma tumors (P < .001). Results of immunohistochemical analysis confirmed VEGFR2 expression on vascular endothelial cells of both tumor types.
US imaging with contrast microbubbles targeted to VEGFR2 allows noninvasive visualization of VEGFR2 expression in tumor vessels in mice.

0 Followers
 · 
103 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Background To evaluate whether Contrast Enhanced Ultrasund (CEUS) with microbubbles (MBs) targeted to VEGFR-2 is able to characterize in vivo the VEGFR-2 expression in the tumor vasculature of a mouse model of thyroid cancer (Tg-TRK-T1). Methods Animal protocol was approved by Institutional committee on Laboratory Animal Care. Contrast-enhanced ultrasound imaging with MBs targeted with an anti-VEGFR-2 monoclonal antibody (UCAVEGFR-2) and isotype control antibody (UCAIgG) was performed in 7 mice with thyroid carcinoma, 5 mice with hyperplasia or benign thyroid nodules and 4 mice with normal thyroid. After ultrasonography, the tumor samples were harvested for histological examination and VEGFR-2 expression was tested by immunohistochemistry. Data were reported as median and range. Paired non parametric Wilcoxon’s test and ANOVA of Kruskal-Wallis were used. The correlation between the contrast signal and the VEGFR-2 expression was assessed by the Spearman coefficient. Results The Video intensity difference (VID) caused by backscatter of the retained UCAVEGFR-2 was significantly higher in mice harboring thyroid tumors compared to mice with normal thyroids (P < 0.01) and to mice harboring benign nodules (P < 0.01). No statistically significant differences of VID were observed in the group of mice carrying benign nodules compared to mice with normal thyroids. Moreover in thyroid tumors VID of retained VEGFR-2-targeted UCA was significantly higher than that of control UCAIgG (P <0.05). Results of immunohistochemical analysis confirmed VEGFR-2 overexpression. The magnitude of the molecular ultrasonographic signal from a VEGFR-2-targeted UCA retained by tissue correlates with VEGFR-2 expression determined by immunohistochemistry (rho 0.793, P=0.0003). Conclusions We demonstrated that CEUS with UCAVEGFR-2 might be used for in vivo non invasive detection and quantification of VEGFR-2 expression in thyroid cancer in mice, and to differentiate benign from malignant thyroid nodules.
    BMC Medical Imaging 09/2013; 13(1):31. DOI:10.1186/1471-2342-13-31 · 0.98 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Ultrasound (US) molecular imaging by examining the expression of vascular endothelial growth factor receptor 2 (VEGFR2) on uterus vascular endothelium was applied to evaluate the endometrial receptivity. VEGFR2-targeted ultrasound contrast agents (UCA) and the control UCA (without VEGFR2) were prepared and characterized. Adhesion experiment in vitro was performed with mouse microvascular endothelial cells (bEnd.3) and the ratio of the number of UCA to that of cells at the same field was compared. In vivo study, randomized boluses of targeted or control UCA were injected into the animals of non-pregnancy (D0), pregnancy on day 2 (D2) and day 4 (D4), respectively. Sonograms were acquired by an ultrasound equipment with a 40-MHz high-frequency transducer (Vevo 2100; VisualSonics, Toronto, Canada). The ultrasonic imaging signals were quantified as the video intensity amplitudes generated by the attachment of VEGFR2-targeted UCA. Immunoblotting and immunofluorescence assays were used for confirmation of VEGFR2 expression. Our results showed that VEGFR2-targeted UCA could bind to bEnd.3 cells with significantly higher affinity than the control UCA (9.8 ± 1.0 bubbles/cell versus 0.7 ± 0.3 bubbles/cell, P < 0.01) in vitro. The mean video intensity from the US backscattering of the retained VEGFR2-targeted UCA was significantly higher than that of the control UCA in D2 and D4 mice (D2, 10.5 ± 2.5 dB versus 1.5 ± 1.1 dB, P < 0.01; D4, 15.7 ± 4.0 dB versus 1.5 ± 1.2 dB, P < 0.01), but not significantly different in D0 mice (1.0 ± 0.8 dB versus 0.9 ± 0.6 dB, P > 0.05). Moreover, D4 mice showed the highest video intensity amplitude, indicating the highest VEGFR2 expression when compared with D2 and D0 mice (P < 0.01). This was further confirmed by our immunoblotting and immunofluorescence experiments. Ultrasound molecular imaging with VEGFR2-targeted UCA may be used for noninvasive evaluation of endometrial receptivity in murine models.
    Theranostics 01/2015; 5(2):206-17. DOI:10.7150/thno.9847 · 7.83 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Ultrasound imaging is a powerful tool in medicine because of the millisecond temporal resolution and sub-millimeter spatial resolution of acoustic imaging. However, the current generation of acoustic contrast agents is primarily limited to vascular targets due to their large size. Nano-size particles have the potential to be used as a contrast agent for ultrasound molecular imaging. Silica-based nanoparticles have shown promise here, however their slow degradation rate may limit their applications as a contrast agent. Phosphate-based glasses are an attractive alternative with controllable degradation rate and easily metabolized degradation components in the body. In this study, biodegradable P2O5-CaO-Na2O phosphate-based glass nanospheres (PGNs) were synthesized and characterized as contrast agents for ultrasound imaging. The structure of the PGNs was characterised using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD), 31P nuclear magnetic resonance (31P MAS-NMR), and Fourier transform infrared (FTIR) spectroscopy. The SEM images indicated a spherical shape with a diameter size range of 200-500 nm. The XRD, 31P NMR and FTIR results revealed the amorphous and glassy nature of PGNs that consisted of mainly Q1 and Q2 phosphate units. We used this contrast to label mesenchymal stem cells and determined in vitro and in vivo detection limits of 5 and 9 ?g/mL, respectively. Cell counts down to 4000 could be measured with ultrasound imaging with no cytoxicity at doses needed for imaging. Importantly, ion release studies confirmed these PGNs biodegrade into aqueous media with degradation products that can be easily metabolized in the body.
    ACS Nano 01/2015; 9(2). DOI:10.1021/nn506789y · 12.03 Impact Factor

Preview (3 Sources)

Download
2 Downloads
Available from