Article

Experimental validation of circumferential, longitudinal, and radial 2-dimensional strain during dobutamine stress echocardlography in ischemic conditions

INSERM U828 and IFR4, University of Bordeaux 2, Bordeaux, France.
Journal of the American College of Cardiology (Impact Factor: 15.34). 01/2008; 51(2):149-57. DOI: 10.1016/j.jacc.2007.07.088
Source: PubMed

ABSTRACT The aim of this study was to assess and validate 2-dimensional (2D) strain for the detection of ischemia during dobutamine stress echocardiography (DSE).
Evaluation of abnormalities of left ventricular (LV) function from wall thickening during DSE is unsatisfactory and requires a high level of expertise.
In 10 open-chest anesthetized pigs, myocardial deformation was studied before and during dobutamine infusion, under control and ischemic conditions produced by various degrees of coronary artery constriction: 2 of nonflow-limiting stenoses (NFLS) of increasing severity reducing left anterior descending artery hyperemic flow by 40% and 70% and 2 flow-limiting stenoses (FLS) reducing resting coronary flow by 25% and 50%. Agreement between 2D strain echocardiography and sonomicrometry (reference method) was evaluated by linear regression and Bland-Altman analysis.
Good correlation and agreement were observed between 2-dimensional strain and sonomicrometry at rest and during dobutamine infusion; longitudinal strain: r = 0.77, p < 0.001 and r = 0.80, p < 0.001; radial strain: r = 0.57, p < 0.05 and r = 0.63, p < 0.05; and circumferential strain: r = 0.74, p < 0.001 and r = 0.58, p < 0.001. Circumferential and longitudinal strains in the risk area were significantly decreased at rest in the presence of FLS and during dobutamine infusion in the presence of NFLS. By contrast, radial strain was significantly decreased in the presence of severe FLS only during dobutamine infusion.
The 2D strain provides accurate assessment of LV regional function. Evaluation of circumferential and longitudinal strains during DSE has real potential for quantitative evaluation of LV deformation in the routine assessment of ischemia.

0 Followers
 · 
67 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Global longitudinal strain (GLS) measured by 2-D speckle-tracking echocardiography (2-D STE) at rest has been recognized as a sensitive parameter in the detection of significant coronary artery disease (CAD). However, the diagnostic power of 2-D STE in the detection of significant CAD in patients with diabetes mellitus is unknown. Two-dimensional STE features were studied in total of 143 consecutive patients who underwent echocardiography and coronary angiography. Left ventricular global and segmental peak systolic longitudinal strains (PSLSs) were quantified by speckle-tracking imaging. In the presence of obstructive CAD (defined as stenosis ≥75%), global PSLS was significantly lower in patients with diabetes mellitus than in patients without (16.65 ± 2.29% vs. 17.32 ± 2.27%, p < 0.05). Receiver operating characteristic analysis revealed that global PSLS could effectively detect obstructive CAD in patients without diabetes mellitus (cutoff value: –18.35%, sensitivity: 78.8%, specificity: 77.5%). However, global PSLS could detect obstructive CAD in diabetic patients at a lower cutoff value with inadequate sensitivity and specificity (cutoff value: –17.15%; sensitivity: 61.1%, specificity: 52.9%). In addition, the results for segmental PSLS were similar to those for global PSLS. In conclusion, global and segmental PSLSs at rest were significantly lower in patients with both obstructive CAD and diabetes mellitus than in patients with obstructive CAD only; thus, PSLSs at rest might not be a useful parameter in the detection of obstructive CAD in patients with diabetes mellitus.
    Ultrasound in Medicine & Biology 11/2014; 41(1). DOI:10.1016/j.ultrasmedbio.2014.08.011 · 2.10 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Background There have been no reports that show significant direct relationship between echocardiographic parameters and B-type natriuretic peptide (BNP) level. This could be due to the heterogeneous pathophysiology of heart failure and a lack of appropriate echocardiographic parameters. We sought to determine the best echocardiographic parameter that described elevated BNP level in patients with heart failure with and without systolic dysfunction.Methods and ResultsWe studied 111 consecutive heart failure patients. They were divided into patients with heart failure and preserved ejection fraction (HFPEF, n = 61) and that with heart failure and reduced ejection fraction (HFREF, n = 50). Conventional and new echocardiographic parameters including myocardial strains were measured. BNP did not reflect any single echocardiographic parameter in patients with heart failure in total. The ratio of early diastolic transmitral flow velocity and mitral annular velocity had strong positive correlation with BNP level in the HFPEF group but not in the HFREF group. In the group of HFREF, global longitudinal and circumferential strains were positively correlated. Multivariate analysis revealed that predicted factors for BNP value in HFPEF and in HFREF were different.Conclusion High BNP level may indicate high filling pressure when ejection fraction is preserved and may indicate myocardial dysfunction when it is reduced.
    Echocardiography 08/2014; 32(4). DOI:10.1111/echo.12707 · 1.25 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Strain and strain-rate imaging (SRI) have been found clinically useful in the assessment of cardiac systolic and diastolic function as well as providing new insights in deciphering cardiac physiology and mechanics in cardiomyopathies, and identifying early subclinical changes in various pathologies. The aim of this study was to evaluate the regional and global left ventricular (LV) myocardial function in metabolic syndrome (MS) with SRI so that we can provide more myocardial small lesions in patients with MS, which is robust and reliable basis for early detection of LV function. Thirty-nine adults with MS were enrolled in the study. There was a control group of 39 healthy adults. In addition to classic echocardiographic assessment of LV global functional changes, SRI was used to evaluate regional and global LV function. Including: Peak systolic strain (S), peak systolic strain-rate (SR-s), peak diastolic strain-rate (SR-e). There were no statistically significant differences between MS and controls in all traditional parameters of LV systolic function. On the other hand, significant differences were observed between MS and the control group in most of the parameters of S, SR-s, SR-e in regional LV function. Multiple stepwise regression analyses revealed that S and SR significantly were negatively correlated with blood pressure, waist circumference, fasting plasma glucose, uric acid, suggesting that risk factories were relevant to regional systolic dysfunction. In MS with normal LV ejection fraction, there was regional myocardial dysfunction, risk factors contributed to the impairment of systolic and diastolic function of the regional myocardium. Assessment of myocardial function using SRI could be more accurate in MS patient evaluation than conventional echocardiography alone.
    Chinese medical journal 01/2015; 128(2):226-32. DOI:10.4103/0366-6999.149211 · 1.02 Impact Factor

Full-text (2 Sources)

Download
13 Downloads
Available from
Jul 22, 2014