Comparison of two column characterisation systems based on pharmaceutical applications.
Katholieke Universiteit Leuven, Laboratorium voor Farmaceutische Analyse, O&N 2, PB 923, Herestraat 49, B-3000 Leuven, Belgium.
Journal of Chromatography (impact factor:
4.53).
06/2008;
1189(1-2):59-71.
DOI:10.1016/j.chroma.2008.02.012
pp.59-71
Source: PubMed
-
Citations (0)
- Cited In (1)
-
Article: Miniaturized protein separation using a liquid chromatography column on a flexible substrate
[show abstract] [hide abstract]
ABSTRACT: We report a prototype protein separator that successfully miniaturizes existing technology for potential use in biocompatible health monitoring implants. The prototype is a liquid chromatography (LC) column (LC mini-column) fabricated on an inexpensive, flexible, biocompatible polydimethylsiloxane (PDMS) enclosure. The LC mini-column separates a mixture of proteins using size exclusion chromatography (SEC) with polydivinylbenzene beads (5–20 µm in diameter with 10 nm pore size). The LC mini-column is smaller than any commercially available LC column by a factor of ~11 000 and successfully separates denatured and native protein mixtures at ~71 psi of the applied fluidic pressure. Separated proteins are analyzed using NuPAGE-gel electrophoresis, high-performance liquid chromatography (HPLC) and an automated electrophoresis system. Quantitative HPLC results demonstrate successful separation based on intensity change: within 12 min, the intensity between large and small protein peaks changed by a factor of ~20. In further evaluation using the automated electrophoresis system, the plate height of the LC mini-column is between 36 µm and 100 µm. The prototype LC mini-column shows the potential for real-time health monitoring in applications that require inexpensive, flexible implant technology that can function effectively under non-laboratory conditions.Journal of Micromechanics and Microengineering 10/2008; 18(12):125010. · 2.11 Impact Factor
Data provided are for informational purposes only. Although carefully collected, accuracy cannot be guaranteed.
The impact factor represents a rough estimation of the journal's impact factor and does not reflect the actual
current impact factor.
Publisher conditions are provided by RoMEO. Differing provisions from the publisher's actual policy or licence
agreement may be applicable.
Keywords
3 chromatographic methods
4 chromatographic parameters
4 methods
4 parameters
6 parameters
6 test parameters
63 columns
appropriate column
brand name
Column Selector
dissimilar columns
download procedures
Euerby methods
KUL approach
particular chromatographic column
reference column
stationary phase
suitable column
support rational column selection
two methods