A software application for comparing large numbers of high resolution MALDI-FTICR MS spectra demonstrated by searching candidate biomarkers for glioma blood vessel formation.

Department of Neurology, Laboratory of Neuro-Oncology, Clinical and Cancer Proteomics, Erasmus Medical Center, Dr, Molewaterplein 50, PO Box 2040, 3000 CA Rotterdam, The Netherlands.
BMC Bioinformatics (Impact Factor: 3.02). 01/2008; 9:133. DOI: 10.1186/1471-2105-9-133
Source: PubMed

ABSTRACT A Java application is presented, which compares large numbers (n > 100) of raw FTICR mass spectra from patients and controls. Two peptide profile matrices can be produced simultaneously, one with occurrences of peptide masses in samples and another with the intensity of common peak masses in all the measured samples, using the peak- and background intensities of the raw data. In latter way, more significantly differentially expressed peptides are found between groups than just using the presence or absence in samples of common peak masses. The software application is tested by searching angiogenesis related proteins in glioma by comparing laser capture micro dissected- and enzymatic by trypsin digested tissue sections.
By hierarchical clustering of the presence-absence matrix, it appears that proteins, such as hemoglobin alpha and delta subunit, fibrinogen beta and gamma chain precursor, tubulin specific chaperone A, epidermal fatty acid binding protein, neutrophil gelatinase-associated lipocalin precursor, peptidyl tRNA hydrolase 2 mitochondrial precursor, placenta specific growth hormone, and zinc finger CCHC domain containing protein 13 are significantly different expressed in glioma vessels. The up-regulated proteins in the glioma vessels with respect to the normal vessels determined by the Wilcoxon-Mann-Whitney test on the intensity matrix are vimentin, glial fibrillary acidic protein, serum albumin precursor, annexin A5, alpha cardiac and beta actin, type I cytoskeletal 10 keratin, calcium binding protein p22, and desmin. Peptide masses of calcium binding protein p22, Cdc42 effector protein 3, fibronectin precursor, and myosin-9 are exclusively present in glioma vessels. Some peptide fragments of non-muscular myosin-9 at the C-terminus are strongly up-regulated in the glioma vessels with respect to the normal vessels.
The less rigorous than in general used commercial propriety software de-isotope algorithm results in more mono-isotopic peptide masses and consequently more proteins. Centroiding of peptide masses takes place by taking the average over more spectra in the profile matrix. Cytoskeleton proteins and proteins involved in the calcium signaling pathway seem to be most up-regulated in glioma vessels. The finding that peptides at the C-terminus of myosin-9 are up-regulated could be ascribed to splicing or fragmentation by proteases.

0 Bookmarks
 · 
60 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: L'endothélium vasculaire est la première couche de cellules en contact avec le flux sanguin. Au cours de processus pathologiques, les cellules endothéliales subissent des remaniements notoires dus à la présence de nombreux facteurs. Dans ce cas, l'intégrité de l'endothélium, assurée principalement par les jonctions adhérentes endothéliales dont la V(ascular)E(ndothelial)-cadhérine est la protéine clé, est perturbée. La phospho-VE-cadhérine est une caractéristique des cellules endothéliales activées in vitro. Notre laboratoire a montré l'existence d'une forme phosphorylée de VE-cadhérine in vivo au cours de l'angiogenèse physiologique. Des tyrosines importantes ont été identifiées : la tyrosine 685, qui est la cible directe de la tyrosine kinase Src en réponse au VEGF ainsi que les tyrosines 658 et 731. De plus, la VE-cadhérine peut être sensible à la protéolyse. Dans ce travail, la phosphorylation de la VE-cadhérine a été étudiée dans un contexte pathologique d'inflammation et de cancer à l'aide de deux modèles murins de tumeurs hépatiques ou cérébrales. J'ai démontré l'existence in vivo d'une forme phosphorylée de VE-cadhérine sur le site Y658. L'analyse d'une tyrosine kinase particulière, Syk, par si RNA ainsi que par des expériences de phosphorylation in vitro suggèrent fortement l'implication de SYK dans cette phosphorylation. En parallèle, dans le cadre d'une étude sur plusieurs pathologies, nous avons mis en évidence la présence d'une forme circulante de VE-cadhérine. La VE-cadhérine, tant par sa phosphorylation que par sa présence dans les fluides biologiques, pourrait être une signature de l'endothélium activé (phosphorylation) et/ou agressé (protéolyse).
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: We developed a new version of the open source software package Peptrix that can yet compare large numbers of Orbitrap™ LC-MS data. The peptide profiling results for Peptrix on MS1 spectra were compared with those obtained from a small selection of open source and commercial software packages: msInspect, Sieve™ and Progenesis™. The properties compared in these packages were speed, total number of detected masses, redundancy of masses, reproducibility in numbers and CV of intensity, overlap of masses, and differences in peptide peak intensities. Reproducibility measurements were taken for the different MS1 software applications by measuring in triplicate a complex peptide mixture of immunoglobulin on the Orbitrap™ mass spectrometer. Values of peptide masses detected from the high intensity peaks of the MS1 spectra by peptide profiling were verified with values of the MS2 fragmented and sequenced masses that resulted in protein identifications with a significant score. Peptrix finds about the same number of peptide features as the other packages, but peptide masses are in some cases approximately 5 to 10 times less redundant present in the peptide profile matrix. The Peptrix profile matrix displays the largest overlap when comparing the number of masses in a pair between two software applications. The overlap of peptide masses between software packages of low intensity peaks in the spectra is remarkably low with about 50% of the detected masses in the individual packages. Peptrix does not differ from the other packages in detecting 96% of the masses that relate to highly abundant sequenced proteins. MS1 peak intensities vary between the applications in a non linear way as they are not processed using the same method. Peptrix is capable of peptide profiling using Orbitrap™ files and finding differential expressed peptides in body fluid and tissue samples. The number of peptide masses detected in Orbitrap™ files can be increased by using more MS1 peptide profiling applications, including Peptrix, since it appears from the comparison of Peptrix with the other applications that all software packages have likely a high false negative rate of low intensity peptide peaks (missing peptides).
    BMC Research Notes 01/2011; 4:21.
  • [Show abstract] [Hide abstract]
    ABSTRACT: Although challenging, proteomic profiling has recently become a hot area in cancer research, and a majority of the currently available methodologies, such as two-dimensional polyacrylamide gel electrophoresis, two-dimensional difference gel electrophoresis, liquid chromatography, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, surface-enhanced laser desorption/ionization time-of-flight MS, tissue microarrays, and protein and antibody arrays, have been used in human brain tumor research. These studies have generated an enormous amount of data, and, in the postproteomics era, more powerful bioinformatics tools are needed to effectively mine proteomics data efficiently and accurately. The design, execution, and interpretation of in vitro and in vivo biological confirmatory experiments constitute major tasks for scientists who seek to identify clinically meaningful diagnostic and prognostic makers.
    12/2008: pages 553-575;

Full-text (3 Sources)