Pre-operative ordering of minimally invasive surgical tools: a fuzzy inference system approach.

Department of Mechanical Engineering, University of Nebraska-Lincoln, N104 Walter Scott Engineering Center, P.O. Box 880656, Lincoln, NE 68588-0656, USA.
Artificial Intelligence in Medicine (Impact Factor: 2.02). 06/2008; 43(1):35-45. DOI: 10.1016/j.artmed.2008.01.003
Source: PubMed


With a limited number of access ports, minimally invasive surgery (MIS) often requires the complete removal of one tool and reinsertion of another in order to provide surgeons with the full functionality necessary to complete a procedure.
Endoscope video from 14 MIS procedures performed at the University of Nebraska Medical Center was used to collect usage statistics for various surgical instruments. This usage data was normalized and input to a fuzzy inference system (FIS) with four membership functions (MFs) to provide a crisp rating value for each instrument. Input membership functions included: number of uses ("Use"), total time used ("Time"), number of changes ("Change") and time per use ("Ave-Time"). Tools were arranged in a simulated cartridge system based on a "Usefulness" output membership function in such a way as to allow easy selection of the next instrument necessary to complete the procedure. Performance was measured by comparing the amount of cartridge indexing needed to complete a procedure using the FIS-generated arrangement against a set of random tool arrangements.
The 14 FIS-generated tool arrangements considered in this investigation performed better than 64.11% of randomly generated tool arrangements and as well or better than 80.48% of tool arrangements. Using the FIS in conjunction with a multifunction laparoscopic tool, it is projected that an average cycle savings of 17.75% and 17.39% can be achieved over the mean and median of the random tool arrangements, respectively.
For a given set of tools, the FIS used in this investigation provides an efficient method of arranging tools for MIS that performs at least as well or better than simply placing the tool tips into the chambers in a random configuration. This leads to a decrease in operating room time and corresponding decreases in both patient trauma from insertion and removal of tools and monetary cost, which is directly related to the amount of time spent changing instruments.

4 Reads
  • [Show abstract] [Hide abstract]
    ABSTRACT: With a limited number of access ports, minimally invasive surgery (MIS) often requires the complete removal of one tool and reinsertion of another. Modular or multifunctional tools can be used to avoid this step. In this study, soft computing techniques are used to optimally arrange a modular tool's functional tips, allowing surgeons to deliver treatment of improved quality in less time, decreasing overall cost. The investigators watched University Medical Center surgeons perform MIS procedures (e.g., cholecystectomy and Nissen fundoplication) and recorded the procedures to digital video. The video was then used to analyze the types of instruments used, the duration of each use, and the function of each instrument. These data were aggregated with fuzzy logic techniques using four membership functions to quantify the overall usefulness of each tool. This allowed subsequent optimization of the arrangement of functional tips within the modular tool to decrease overall time spent changing instruments during simulated surgical procedures based on the video recordings. Based on a prototype and a virtual model of a multifunction laparoscopic tool designed by the investigators that can interchange six different instrument tips through the tool's shaft, the range of tool change times is approximately 11-13 s. Using this figure, estimated time savings for the procedures analyzed ranged from 2.5 to over 32 min, and on average, total surgery time can be reduced by almost 17% by using the multifunction tool.
    Surgical Endoscopy 02/2009; 23(5):1099-105. DOI:10.1007/s00464-008-0321-2 · 3.26 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: A root canal surgery involves the successive use of several tools one after another. Typically dozens of tools are laid out for possible use, and the process of tool selection is done manually. This is a rather inefficient process and uses up a large area on the mobile cart or cabinet of the dental chair due to the large number of tools. In this article, a novel 'tool vending machine' is introduced which will be capable of solving those problems and at the same time move a step closer to robot-assisted dental surgery. The tool vending machine was designed considering the needs of the dentists and also from the perspective of the entire product life cycle. For these reasons the design process was implemented using a rigorous analysis of effective manufacturing processes and product quality. To show the feasibility of using such a machine in improving work efficiency during operations, a study of the associated motion patterns and the required time increments were demonstrated.
    Journal of Medical Engineering & Technology 02/2012; 36(2):102-16. DOI:10.3109/03091902.2011.645944
  • [Show abstract] [Hide abstract]
    ABSTRACT: The techniques in the construction industry have been improved due to the rapid development of science and technology. However, the constructional hazards are not decreased as expected. To reduce or prevent occupational hazards in the construction industry, a fuzzy risk assessment method was proposed to provide a prevention and improvement technique against occupational hazards. This method used two-stage quality function deployment (QFD) tables to represent the relationships among construction items, hazard types and hazard causes. A fuzzy analytic network process (ANP) method was developed to identify important hazard types and hazard causes. Failure modes and effect analysis (FMEA) was performed to assess the risk value of hazard causes based on the fuzzy inference approach. The proposed method was applied to a telecom engineering company in southern Taiwan. The performance evaluation result indicated that this method can provide satisfactory risk assessment values of hazard causes and relevant improvement strategies.
    Safety Science 04/2012; 50(4):1067–1078. DOI:10.1016/j.ssci.2011.11.021 · 1.83 Impact Factor
Show more