Article

MDCT angiography of the pulmonary arteries: intravascular contrast enhancement does not depend on iodine concentration when injecting equal amounts of iodine at standardized iodine delivery rates.

Department of Diagnostic Radiology, University Hospital, RWTH Aachen University, Pauwelsstrasse 30, 52074, Aachen, Germany.
European Radiology (impact factor: 3.22). 09/2008; 18(8):1690-5. DOI:10.1007/s00330-008-0942-9 pp.1690-5
Source: PubMed

ABSTRACT To compare the impact of iodine concentration using two different contrast materials (CM) at standardized iodine delivery rate (IDR) and overall iodine load in 16-multidetector-row-CT-angiography (MDCTA) of the pulmonary arteries of 192 patients with known or suspected pulmonary embolism. One hundred three patients (group A) received 148 ml of a CM containing 300 mg iodine/ml (Ultravist 300, BayerScheringPharma) at a flow rate of 4.9 ml/s. Eighty-nine patients (group B) received 120 ml of a CM with a concentration of 370 mg iodine/ml (Ultravist 370) at a flow rate of 4.0 ml/s, resulting in a standardized IDR (approximately 1.5 gI/s) and the same overall amount of iodine (44.4 g). Both CM injections were followed by a saline chaser. Mean density values were determined in the pulmonary trunk, the ascending and the descending aorta, respectively. Applying repeated-measures ANOVA, no statistically significant differences between both MDCTA protocols were found (p = 0.5790): the mean density in the pulmonary trunk was 355 +/- 116 Hounsfield Units (group A) and 358 +/- 115 (group B). The corresponding values for the ascending and descending aorta were 295 +/- 79 (group A) and 284 +/- 65 (group B) as well as 272 +/- 71 and 262 +/- 70. In conclusion, the use of standardized IDR and overall iodine load provides comparable intravascular CM density in pulmonary 16-MDCTA for delivering contrast materials with different iodine concentrations.

0 0
 · 
0 Bookmarks
 · 
22 Views
  • Article: CT perfusion of head and neck tumors: how we do it.
    [show abstract] [hide abstract]
    ABSTRACT: OBJECTIVE: Our purpose is to illustrate the pathophysiologic, physical, and technical principles of MDCT perfusion imaging of head and neck tumors. The rationale for data acquisition and the interpretation of perfusion parameters will be discussed in the context of results recently published in the literature. CONCLUSION: MDCT perfusion imaging of primary and recurrent head and neck tumors is feasible and can yield functional information that is useful for tumor grading and assessment of treatment response.
    American Journal of Roentgenology 01/2010; 194(1):62-9. · 2.78 Impact Factor