Article

Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography.

Cardiology Unit, San Gennaro Hospital, ASL Napoli 1, Naples, Italy.
Journal of Cardiovascular Medicine (Impact Factor: 2.66). 06/2008; 9(5):485-92. DOI: 10.2459/JCM.0b013e3282f2c9e3
Source: PubMed

ABSTRACT The aim of the present study was to assess the in-stent restenosis and occlusion of coronary artery stents by multislice computed tomography (MSCT) compared with conventional coronary angiography in patients with atypical chest pain and not practicable/non-conclusive stress test.
Between December 2004 and March 2006, 81 patients were scheduled and of these 72 (65 men, mean age 61 years) with 90 stents underwent MSCT angiography using a 16-slice scanner, Toshiba Aquilion 16, 8-12 months after stent placement.
Of the 90 stents, 71 (79%) could be assessed and 19 (21%) were excluded because the image quality at the stent level was incompatible with diagnostic assessment. This results in sensitivity, specificity, and positive and negative predictive values for all assessable stents in the identification of occlusion and/or in-stent restenosis of 82, 96, 87, and 94%, respectively. When the 19 uninterpretable stents were included in the analysis, the diagnostic accuracy of MSCT in detecting in-stent restenosis and occlusion resulted in a sensitivity of 82%, specificity of 71%, positive predictive value of 40%, and negative predictive value of 94%.
The results of the study suggest that MSCT angiography is a useful method for evaluating patency/occlusion of large (>or=3 mm) coronary stents in symptomatic patients with atypical chest pain and concomitant not practicable/non-conclusive exercise or stress imaging test.

0 Bookmarks
 · 
55 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: The investigators conducted a review to evaluate the diagnostic performance of multidetector computed tomography (MDCT) for coronary stent evaluation. The prespecified inclusion criteria selected prospective or retrospective human studies published in English. Studies that did not report raw numbers of diagnostic accuracy for the detection of in-stent restenosis were excluded. The data from 24 studies are reported, 6 performed with old-generation scanners (4-, 16-, and 40-slice MDCT) and 18 performed with 64-slice MDCT or dual-source MDCT. With old-generation MDCT, up to 18% of coronary stents were missed, the rate of nonevaluable stents ranged from 2.6% to 23.5%, and the overall feasibility and diagnostic accuracy were 90.4% and 90%, respectively. With 64-slice MDCT, no stent was missed, and the overall feasibility and diagnostic accuracy were 90.4% and 91.9%, respectively. Advancements in MDCT and stent technologies may further reduce the number of nonassessable stents and improve diagnostic performance.
    The American journal of cardiology 03/2010; 105(5):645-55. · 3.58 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: A careful post-mortem investigation is needed to determine the cause of death of patients bearing coronary stents and to describe complications of stent implantation. The main purpose of this study was to combine post mortem methods of CT angiography and corrosion cast preparation for the visualization of coronary stenoses, coronary stents, instent restenosis, and stent occlusion. Injection-corrosion method was combined with post-mortem MSCT angiography to characterize the pathomorphological changes after stent implantation in 6 male cadaver hearts. Multi-slice computed tomography was employed to visualize the coronary artery system. For image post processing, multiplanar reconstructions, maximal intensity projections and three dimensional reconstructions were used. This study was assessing the feasibility of post mortem MSCT for intracoronary stent evaluation. We described a method for characterisation of the coronary side branch stenosis caused by stent implantation. Post mortem CT imaging proved to be a feasible and highly reproducible technique for the characterisation of pathological changes in the coronary system.
    Legal Medicine. 01/2014;
  • [Show abstract] [Hide abstract]
    ABSTRACT: To determine factors affecting the ability of 64-multislice computed tomography (MSCT) to detect, assess, and accurately diagnose significant coronary arterial in-stent restenosis (ISR). The institutional review board approved this study and waived informed consent. Sixty patients underwent CT coronary angiography using 64-MSCT, after implantation of coronary artery stents (n=91). We assessed diagnostic accuracy for ISR with CT in comparison with conventional coronary angiography as the gold standard, visually and with measurement of in-stent coronary lumen density. Possible factors that influenced the diagnostic performance of CT were evaluated, which included image quality (IQ), stent characteristics, and location. Sixty-nine stents (75.8%) were assessable. Low IQ, location in the left circumflex coronary artery, and narrow stent diameter were associated with poor assessment (P<0.05). In stents that could be assessed, sensitivity, specificity, positive predictive value, and negative predictive value of 64-MSCT were 90.0%, 73.5%, 58.1%, and 94.7%, respectively, for significant ISR. The diagnostic accuracy in assessable stents showed a significant increase with better IQ, thinner strut thickness, and nondrug eluting stent. False-positive diagnoses of ISR by CT were explained by coronary lumen density measurements. Evaluation of stents by 64-MSCT is not recommended in stents with diameters of < or = 2.75 mm or stents located at the left circumflex coronary artery. The diagnostic accuracy of 64-MSCT is affected by IQ and strut thickness in assessable stents. Significant ISR can be excluded with high reliability in selected patients.
    Journal of thoracic imaging 02/2010; 25(1):57-63. · 1.42 Impact Factor

Full-text

View
13 Downloads
Available from
Jun 1, 2014