Reaction of fluorogenic reagents with proteins III. Spectroscopic and electrophoretic behavior of proteins labeled with Chromeo P503.

Department of Chemistry, University of Washington, Seattle, WA 98195, USA.
Journal of Chromatography A (Impact Factor: 4.61). 07/2008; 1194(2):253-6. DOI: 10.1016/j.chroma.2008.04.046
Source: PubMed

ABSTRACT The spectroscopic and electrophoretic properties of proteins labeled with Chromeo P503 were investigated. Its photobleaching characteristics were determined by continually infusing Chromeo P503-labeled alpha-lactalbumin into a sheath-flow cuvette and monitored fluorescence as a function of laser power. The labeled protein is relatively photo-labile with an optimum excitation power of about 2 mW. The unreacted reagent is weakly fluorescent but present at much higher concentration than the labeled protein. The unreacted reagent undergoes photobleaching at a laser power more than an order of magnitude higher than the labeled protein. One-dimensional capillary electrophoresis analysis of Chromeo P503-labeled alpha-lactalbumin produced concentration detection limits (3sigma) of 12 pM and mass detection limits of 0.7 zmol, but with modest theoretical plate counts of 17,000. The reagent was employed for the two-dimensional capillary electrophoresis analysis of a homogenate prepared from a Barrett's esophagus cell line; the separation quality is similar to that produced by 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ), a more commonly used reagent.

0 Bookmarks
 · 
90 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: We report a multiplexed capillary electrophoresis system employing an array of 32 capillaries with a micromachined sheath-flow cuvette as the detection chamber. The sample streams were simultaneously excited with a 473-nm laser beam, and the fluorescence emission was imaged on a CCD camera with a pair of doublet achromat lens. The instrument produced mass detection limits of 380 +/- 120 yoctomoles for fluorescein in zone electrophoresis. Capillary isoelectric focusing of fluorescent standards produced peaks with an average width of 0.0029 +/- 0.0008 pH. Capillary coating stability limits the reproducibility of the analysis.
    Analytical and Bioanalytical Chemistry 03/2010; 397(8):3305-10. · 3.66 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2-D separation method for proteins. In this method, two capillaries are joined through a buffer-filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo P503, which preserves the isoelectric point of the labeled protein. The labeled proteins were mixed with ampholytes and injected into the first-dimension capillary. A focusing step was performed with the injection end of the capillary at high pH and the interface at low pH. To mobilize components, the interface was filled with a high pH buffer, which was compatible with the second-dimension separation. A fraction was transferred to the second-dimension capillary for separation. The process of fraction transfer and second dimension separation was repeated two dozen times. The separation produced a spot capacity of 125.
    Electrophoresis 08/2010; 31(15):2650-4. · 3.26 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Capillary gel electrophoresis (CGE) in the presence of sodium dodecyl sulfate (SDS) is a well-established and widely used protein analysis technique in the biotechnology industry, and increasingly becoming the method of choice that meets the requirements of the standards of International Conference of Harmonization (ICH). Automated single channel capillary electrophoresis systems are usually equipped with UV absorbance and/or laser-induced fluorescent (LIF) detection options offering general applicability and high detection sensitivity, respectively; however, with limited throughput. This shortcoming is addressed by the use of multicapillary gel electrophoresis (mCGE) systems with LED-induced fluorescent detection (LED-IF), also featuring automation and excellent detection sensitivity, thus widely applicable to rapid and large-scale analysis of biotherapeutics, especially monoclonal antibodies (mAb). The methodology we report in this paper is readily applicable for rapid purity assessment and subunit characterization of IgG molecules including detection of non-glycosylated heavy chains (NGHC) and separation of possible subunit variations such as truncated light chains (Pre-LC) or alternative splice variants. Covalent fluorophore derivatization and the mCGE analysis of the labeled IgG samples with multi-capillary gel electrophoresis are thoroughly described. Reducing and non-reducing conditions were both applied with and without peptide N-glycosidase F mediated deglycosylation.
    Analytical and Bioanalytical Chemistry 07/2012; 404(5):1485-94. · 3.66 Impact Factor