ABSTRACT Successful application of the Hadamard transform (HT) technique to gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS) is described. Novel sample injection devices were developed to achieve multiple sample injections in both GC and LC instruments. Air pressure was controlled by an electromagnetic valve in GC, while a syringe pump and Tee connector were employed for the injection device in LC. Two well-known, abused drugs, 3,4-methylenedioxy-N-methylamphetamine (MDMA) and N, N-dimethyltryptamine (DMT), were employed as model samples. Both of the injection devices permitted precise successive injections, resulting in clearly modulated chromatograms encoded by Hadamard matrices. After inverse Hadamard transformation of the encoded chromatogram, the signal-to-noise (S/N) ratios of the signals were substantially improved compared with those expected from theoretical values. The S/N ratios were enhanced approximately 10-fold in HT-GC/MS and 6.8 in HT-LC/MS, using the matrices of 1023 and 511, respectively. The HT-GC/MS was successfully applied to the determination of MDMA in the urine sample of a suspect.

0 Followers
 · 
121 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Die Anwendung von Informationstechnologie in der Gaschromatographie wird vorgestellt. Multiplexing‐Gaschromatographie steigert Auslastungsgrad, Signal/Rausch‐Verhältnis und ermöglicht außergewöhnlich hohe Probendurchsätze. Parameter wie Sequenzlänge, Modulationsintervall sowie Anzahl wiederholter Injektionen im Hochdurchsatzmodus bestimmen die Leistungsfähigkeit dieser Methode. Die vorgestellte Technik eröffnet neue Perspektiven in der Prozessanalytik durch kontinuierliche Überwachung eines chemischen Prozesses bei gleichzeitiger Analyse aller vorhandenen Analyte. The utilization of information technology in gas chromatography is demonstrated. Multiplexing gas chromatography enhances the overall duty cycle, signal‐to‐noise ratio and enables achieving extraordinarily high sample throughputs. Parameters such as sequence length, modulation interval and number of repetitive injections in the high‐throughput mode determine overall performance of such systems. The portrayed technique opens new perspectives in process analytics by allowing continuous monitoring of chemical processes while analyzing the complete spectrum of analytes. German Die chromatographische Analyse chemischer Prozesse im industriellen Maßstab ist ressourcenintensiv. Die Kombination aus Informationstechnologie und Trenntechniken in der Multiplexing‐Chromatographie eröffnet neue Perspektiven in der Prozessanalytik, da komplexe Reaktionsgemische kontinuierlich mit hoher Zeitauflösung gemessen werden können.
    Chemie Ingenieur Technik 01/2014; 86(7). DOI:10.1002/cite.201400041 · 0.66 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The Hadamard transform-gas chromatography/mass spectrometry (HT-GC/MS) technique was successfully employed to detect acetone, a biomarker for diabetes mellitus (DM) prediction, in human breath. Samples of exhaled breath were collected from four DM patients (one type-I and three type-II) and eight volunteers (nondiabetic healthy subjects), respectively. The gas samples, without any pretreatment, were simultaneously injected into a GC column through a Hadamard-injector based on Hadamard codes. Under optimized conditions, when cyclic S-matrix orders of 255, 1023 and 2047 were used, the S/N ratios of the acetone signals were substantially improved by 8.0-, 16.0- and 22.6-fold, respectively; these improvements are in good agreement with theoretically calculated values. We found that the breath acetone concentration levels in the four DM patients and the eight volunteers ranged from 1 to 10ppmv and 0.1 to 1ppmv, respectively.
    Talanta 03/2014; 120:386-90. DOI:10.1016/j.talanta.2013.12.025 · 3.51 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: HPLC is an indispensable technique to separate, quantify and identify a broad range of compounds. Recent advances in HPLC technology led to the development of ultra high performance instruments that allow rapid sample analysis with high efficiency. Nevertheless there is still the opportunity to increase the sample throughput and to improve the signal-to-noise ratio by the application of multiplexing, where the injected samples are encoded with defined sequences. The obtained signal is then deconvoluted to give conventional chromatograms. In this work we present a method and technique which can be easily implemented in commercially available HPLC instruments to perform multiplexing analysis. Using our approach, multiplexing can be performed on standard laboratory equipment by software control and offers an inherent advantage in sensitivity and minimization of analysis time, demonstrated for the analysis of highly diluted polynuclear aromatic hydrocarbon (PAH) samples in water.