Article

Comparative evaluation of the Vitek-2 Compact and Phoenix systems for rapid identification and antibiotic susceptibility testing directly from blood cultures of Gram-negative and Gram-positive isolates

Centro Integrato di Ricerche, Laboratory of Clinical Microbiology, University Campus Bio-medico, 00128 Rome, Italy.
Diagnostic microbiology and infectious disease (Impact Factor: 2.57). 01/2012; 72(1):20-31. DOI: 10.1016/j.diagmicrobio.2011.09.015
Source: PubMed

ABSTRACT We performed a comparative evaluation of the Vitek-2 Compact and Phoenix systems for direct identification and antimicrobial susceptibility testing (AST) from positive blood culture bottles in comparison to the standard methods. Overall, 139 monomicrobial blood cultures, comprising 91 Gram-negative and 48 Gram-positive isolates, were studied. Altogether, 100% and 92.3% of the Gram-negative isolates and 75% and 43.75% of the Gram-positive isolates showed concordant identification between the direct and the standard methods with Vitek and Phoenix, respectively. AST categorical agreements of 98.7% and 99% in Gram-negative and of 96.2% and 99.5% in Gram-positive isolates with Vitek and Phoenix, respectively, were observed. In conclusion, direct inoculation procedures for Gram-negative isolates showed an excellent performance with both automated systems, while for identification of Gram-positive isolates they proved to be less reliable, although Vitek provided acceptable results. This approach contributes to reducing the turnaround time to result of blood cultures, with a positive impact on patient care.

0 Followers
  • [Show abstract] [Hide abstract]
    ABSTRACT: Sepsis represents a life-threatening infection requiring the immediate start of antibacterial treatment to reduce morbidity. Thus, laboratories use direct antimicrobial susceptibility testing (AST) to rapidly generate preliminary results from positive blood cultures. As the direct AST has not yet been published to be evaluated with EUCAST breakpoints, the purpose of the study was to investigate the reliability of the direct agar diffusion test to correctly produce AST results from positive monobacterial blood cultures compared with the VITEK2-based definitive AST, when current EUCAST breakpoints were used. A total of 428 isolates from unselected monobacterial routine blood cultures and 110 challenge strains were included. Direct agar diffusion-based and standard VITEK2-based AST of 2803 bacterium-drug combinations yielded a total clinical category agreement of 95.47% with 1.28% very major errors and 3.42% combined major and minor errors. On the species level, very major errors were observed in the species-drug combinations Enterococcus spp.-high-level gentamicin (10.87%) and Staphylococcus spp.-rifampicin (5%), only. No very major errors occurred with Enterobacteriaceae and Pseudomonas aeruginosa. In most species-drug combinations, the direct agar diffusion test using EUCAST breakpoints precisely predicted the result of the definitive antibiotic susceptibility test and, thus, it can be used to optimize empiric antibiotic therapy until definitive results are available.
    European Journal of Microbiology and Immunology 03/2015; 5(1):103-11. DOI:10.1556/EUJMI-D-15-00005
  • [Show abstract] [Hide abstract]
    ABSTRACT: For antibiotic susceptibility results, conventional culture and sensitivity methods takes 48 hours after a blood culture is flagged positive by automated systems. Early initiation of targeted antibiotic therapy is essential for effective management of sepsis to reduce morbidity, mortality, cost of treatment and prevent antibiotic resistance. Objective of this study was to evaluate Direct Sensitivity Test (DST) as a potential tool to get reliable antibiotic susceptibility results 24 hours earlier. Blood cultures flagged positive between May 2011 to December 2012 by BacT/ALERT were Gram stained. All uni-microbial gram-negative blood cultures were simultaneously cultured and processed for DST from broth using disk diffusion method using British Society of Antimicrobial Chemotherapy (BSAC) guidelines. DST results available next day were compared with conventional antibiotic susceptibility test (AST) performed by Vitek-2 on isolated colonies. RESULTS of DST (test method) and AST (reference method) were compared for agreements or errors. Of the 840 antibiotic gram-negative organism combinations tested, Categorical and essential agreements were 83.7% and 96.2% respectively. Minor, major and very major errors were 12.5%, 3.33% and 0.47%, respectively. DST using disk diffusion from positive blood culture broths helps to initiate early targeted antibiotic therapy. There is high concordance between DST and AST.
    Indian Journal of Medical Microbiology 02/2015; 33 Suppl(5):S53-8. DOI:10.4103/0255-0857.150883 · 1.04 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The rapid identification and antibiotic susceptibility test of bacteria causing bloodstream infections are given a very high priority by clinical laboratories. In an effort to reduce the time required for performing antibiotic susceptibility test (AST), we have developed a new method to be applied from positive blood culture bottles. The design of method was performed using blood culture bottles prepared artificially with five strains which have a known susceptibility. An aliquot of the blood culture was subcultured in the presence of specific antibiotics and bacterial counts were monitored using the Sysmex UF-1000i flow cytometer at different times up to 180min. Receiver operating curve (ROC) analysis allowed us to find out the cut-off point for differentiating between sensitive and resistant strains to the tested antibiotic. This procedure was then validated against standard commercial methods on a total of 100 positive blood culture bottles from patients. First, bacterial identification was performed by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS) directly from positive blood culture bottles as we have previously reported. Secondly, antibiotic susceptibility test was performed in the same way that was carried out in artificially prepared blood culture bottles. Our results indicate that antibiotic susceptibility test can be determined as early as 120min since a blood culture bottle is flagged as positive. The essential agreement between our susceptibility test and commercial methods (E-test, MicroScan and Vitek) was 99%. In summary, we conclude that reliable results on bacterial identification and antibiotic susceptibility test performed directly from positive blood culture bottles can be obtained within 3h. Copyright © 2014. Published by Elsevier B.V.
    Journal of Microbiological Methods 12/2014; 109. DOI:10.1016/j.mimet.2014.12.007 · 2.10 Impact Factor