Revisiting the effect of room size and general ventilation on the relationship between near- and far-field air concentrations.
Institute of Occupational Medicine, Research Avenue North, Edinburgh EH14 4AP, UK.
Journal Article: Annals of Occupational Hygiene (impact factor: 1.91). 11/2011; 55(9):1006-15. DOI: 10.1093/annhyg/mer092
Abstract
Pollutant dispersion has been simulated using a two-compartment well-mixed box model to represent the NF and the FF. Simulations were repeated for a range of room sizes and ventilation conditions. Intermittent sources (e.g. batch processes) were simulated by having the source active for 1 h followed by a 1-h gap, while short duration work emissions were set to last for 10 min, 30 min, 1 h, or 4 h, within the working day. Deposition was modeled by adding an equivalent air exchange rate based on published research data. Simulations were undertaken for non-volatile, monodisperse aerosols of aerodynamic diameter: 0.3, 1, 3, 10, 30, and 100 μm and the results were then interpreted in terms of typical polydisperse industrial aerosols.
Room size and general ventilation strongly influenced dispersion from the NF to the FF as Cherrie had originally found. When varying the duration of the simulation, the biggest difference from continuous work was seen in small poorly ventilated rooms, with the ratio of the NF to FF concentration for 1-h work in the smallest room and lowest air exchange rate being a fifth of that calculated for continuous work. For large rooms and high general ventilation rates, the duration of the activity made little difference to dispersion. The results suggest that for the purposes of dispersion intermittent batch work is equivalent to continuous work. For typical simulated poly-disperse aerosols, the main effect of aerosol deposition was to reduce the predicted high concentrations compared to vapours when working in confined spaces.
Both short duration of source emissions and deposition of aerosols have an important effect on dispersion, and the results from this study have been reflected in the ART model.
Source: PubMed
Comments on this publication
ResearchGate members can add comments. Sign up now and post your comment!
Similar publications
The effect of room size and general ventilation on the relationship between near and far-field concentrations.
Applied occupational and environmental hygiene. 14(8):539-46.
Analytical solutions to compartmental indoor air quality models with application to environmental tobacco smoke concentrations measured in a house.
Journal of the Air & Waste Management Association (1995). 53(8):918-36.
Sorption of VOCs on material surfaces as the deciding factor when choosing a ventilation strategy
Building and Environment.
The equilibrium factor F.
Health physics. 45(2):453-62.
Data provided are for informational purposes only. Although carefully collected, accuracy cannot be guaranteed. The impact factor represents a rough estimation of the journal's impact factor and does not reflect the actual current impact factor. Publisher conditions are provided by RoMEO. Differing provisions from the publisher's actual policy or licence agreement may be applicable.