Article

Radiofrequency Guide Wire Recanalization of Venous Occlusions in Patients with Malignant Superior Vena Cava Syndrome

Department of Interventional Radiology, Sunnybrook Health Sciences Centre, Tronto, Ontario, Canada.
CardioVascular and Interventional Radiology (Impact Factor: 1.97). 10/2011; 35(3):676-9. DOI: 10.1007/s00270-011-0279-7
Source: PubMed

ABSTRACT Fibrotic central venous occlusions in patients with thoracic malignancy and prior radiotherapy can be impassable with standard catheters and wires, including the trailing or stiff end of a hydrophilic wire. We report two patients with superior vena cava syndrome in whom we successfully utilized a radiofrequency guide wire (PowerWire, Baylis Medical, Montreal, Quebec, Canada) to perforate through the occlusion and recanalize the occluded segment to alleviate symptoms.

0 Followers
 · 
64 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Superior vena cava syndrome results from the obstruction of blood flow through the superior vena cava and is most often due to thoracic malignancy. However, benign etiologies are on the rise secondary to more frequent use of intravascular devices such as central venous catheters and pacemakers. Although rarely a medical emergency, the symptoms can be alarming, particularly to the patient. Traditionally, superior vena cava syndrome has been managed with radiotherapy and chemotherapy. But interventional endovascular techniques have made inroads that offer a safe, rapid, and durable response. In many cases, it may be the only reasonable treatment. Because of this, an approach to endovascular treatment of this condition must be in the armamentarium of the interventional radiologist. This review will provide the reader with an insight into the etiology, pathophysiology, and various management principles of superior vena cava syndrome. The focus will be on understanding the techniques used during various endovascular interventions, including angioplasty, stenting, and pharmacomechanical thrombolysis. Discussion will also be centered on possible complications and current evidence as well as controversies regarding these approaches.
    Canadian Association of Radiologists Journal 02/2013; 65(2). DOI:10.1016/j.carj.2012.09.003 · 0.58 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: We describe a case of successful recanalization of a longstanding right common iliac occlusion with a radiofrequency (RF) guidewire. The patient had been symptomatic with claudication for 3 years, and a preliminary attempt to cross the lesion using conventional techniques proved unsuccessful. Using low and medium intensity RF pulses and a PowerWire, a tract through the occlusion was established, which allowed subsequent stenting with an excellent angiographic result and a good immediate clinical response. We propose this as a useful technique in the peripheral arterial system for occlusive lesions not amenable to traditional recanalization techniques.
    CardioVascular and Interventional Radiology 12/2011; 35(5):1221-5. DOI:10.1007/s00270-011-0327-3 · 1.97 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: To report the technique and acute technical results associated with the PowerWire Radiofrequency (RF) Guidewire used to recanalize central vein occlusions (CVOs) after the failure of conventional endovascular techniques. A retrospective study was conducted from January 2008 to December 2011, which identified all patients with CVOs who underwent treatment with a novel RF guide wire. Forty-two symptomatic patients (with swollen arm or superior vena cava [SVC] syndrome) underwent RF wire recanalization of 43 CVOs, which were then implanted with stents. The distribution of CVOs in central veins was as follows: six subclavian, 29 brachiocephalic, and eight SVC. All patients had a history of central venous catheter placement. Patients were monitored with regular clinical evaluations and central venography after treatment. All 42 patients had successful recanalization of CVOs facilitated by the RF wire technique. There was one complication, which was not directly related to the RF wire: one case of cardiac tamponade attributed to balloon angioplasty after stent placement. Forty of 42 patients (95.2%) had patent stents and were asymptomatic at 6 and 9 months after treatment. The present results suggest that the RF wire technique is a safe and efficient alternative in the recanalization of symptomatic and chronic CVOs when conventional endovascular techniques have failed.
    Journal of vascular and interventional radiology: JVIR 06/2012; 23(8):1016-21. DOI:10.1016/j.jvir.2012.05.049 · 2.15 Impact Factor