Pulmonary embolism: ct signs and cardiac biomarkers for predicting right ventricular dysfunction.

T Henzler, S Roeger, M Meyer, U J Schoepf, J W Nance, D Haghi, W E Kaminski, M Neumaier, S O Schoenberg, C Fink

University Medical Center Mannheim, Medical Faculty Mannheim-Heidelberg University, Germany.

Journal Article: European Respiratory Journal (impact factor: 5.53). 09/2011; DOI: 10.1183/09031936.00088711

Abstract

To prospectively evaluate the accuracy of quantitative cardiac CT parameters and two cardiac biomarkers (NT-pro-Brain Natriuretic Peptide (NT-pro-BNP); troponin I), alone and in combination, for predicting right ventricular dysfunction (RVD) in patients with acute pulmonary embolism (PE).557 consecutive patients with suspected PE underwent pulmonary CTA. Patients with PE also underwent echocardiography and NT-pro-BNP/troponin I serum level measurements. 3 different CT measurements were obtained (RV/LVaxial, RV/LV4-CH), and RV/LVvolume). CT measurements and NT-pro-BNP/troponin I serum levels were correlated with RVD at echocardiography.Patients with RVD (n=77) showed significantly higher RV/LV ratios and NT-pro-BNP/troponin I levels compared to those without RVD (RV/LVaxial 1.68±0.84 vs. 1.00±0.21; RV/LV4ch 1.52±0.45 vs. 1.01±0.21; RV/LVvolume 1.97±0.53 vs. 1.07±0.52; serum NT-pro-BNP 6372±2319 vs. 1032±1559 ng·L(-1); troponin I 0.18±0.41 vs. 0.06±0.18). The area under the curve for the detection of RVD of RV/LVaxial, RV/LV4Ch, RV/LVvolume, NT-pro-BNP and troponin I were 0.84, 0.87, 0.93, 0.83 and 0.70 respectively. The combination of biomarkers and RV/LVvolume increased the AUC to 0.95 (RV/LVvolume with NT-pro-BNP) and 0.93 (RV/LVvolume with troponin I).RV/LVvolume is the most accurate CT parameter for identifying patients with RVD. A combination of RV/LVvolume with NT-pro-BNP or troponin I measurements improves the diagnostic accuracy of either test alone.

Source: PubMed

Comments on this publication

ResearchGate members can add comments. Sign up now and post your comment!

Similar publications

Science & Research Jobs

Keywords

3 different CT measurements
 
accurate CT parameter
 
acute pulmonary embolism
 
cardiac biomarkers
 
CT measurements
 
diagnostic accuracy
 
echocardiography.Patients
 
higher RV/LV ratios
 
NT-pro-BNP/troponin
 
NT-pro-Brain Natriuretic Peptide
 
PE).557 consecutive patients
 
prospectively
 
pulmonary CTA
 
quantitative cardiac CT parameters
 
RV/LV4-CH
 
RV/LV4Ch
 
RV/LVvolume
 
RVD
 
troponin I).RV/LVvolume
 
ventricular dysfunction