Article

The Effect of Poly Sterilization on Wear, Osteolysis and Survivorship of a Press-fit Cup at 10-Year Followup

Anderson Orthopaedic Research Institute, PO Box 7088, Alexandria, VA 22307, USA.
Clinical Orthopaedics and Related Research (Impact Factor: 2.88). 09/2011; 470(2):462-70. DOI: 10.1007/s11999-011-2052-2
Source: PubMed

ABSTRACT During the mid-1990s when our institution was using a press-fit porous-coated cup without supplemental initial fixation for primary THA, the manufacturer transitioned from gamma irradiation to gas plasma for the terminal sterilization of their polyethylene liners.
At minimum 10-year followup, we asked whether the fixation achieved by solely relying on a press-fit would be durable and how different liner sterilization methods affected radiographic wear, osteolysis, and survivorship.
We retrospectively reviewed 373 patients who underwent 398 primary THAs with a press-fit porous-coated cup between March 1995 and December 1996. Mean age at time of surgery was 61.5 ± 13.3 years and mean followup was 10.4 ± 3.7 years. We determined reasons for revision, survivorship, femoral head penetration, osteolysis, and wear-related complications.
Among 20 revisions involving any component, seven were associated with wear and osteolysis. Kaplan-Meier survivorship, using component revision for any reason as an end point, was 95.7% (95% confidence interval, 93.6%-97.9%) at 10 years. Noncrosslinked liners sterilized with gas plasma demonstrated a mean head penetration rate of 0.20 ± 0.09 mm/year compared with 0.13 ± 0.07 mm/year for liners sterilized with gamma irradiation in air and 0.09 ± 0.04 mm/year for liners sterilized with gamma-irradiation with barrier packaging without oxygen. THAs with increased volumetric wear tended to demonstrate larger osteolytic lesions (r = 0.40) and there tended to be less osteolysis among the liners sterilized with gamma-irradiation with barrier packaging without oxygen. However, there was no difference in survivorship among the sterilization groups and there has been no cup or stem loosening associated with osteolysis.
Durable biologic fixation through 10-year followup can be achieved by solely relying on an initial press-fit. Noncrosslinking gas plasma for terminal sterilization of the polyethylene liners was associated with greater head penetration rate than gamma irradiation.
Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

0 Followers
 · 
97 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Polyethylene (PE) wear and osteolysis is a recognised problem with non-cross linked PE liners and first generation modular cup designs. Wear particles induce osteolysis leading to aseptic loosening. We retrospectively compared the linear PE wear and implant survival and revision rates of the Reflection Cup and the Duraloc 300. After a mean clinical follow-up of 13 years (range 11-15 years), the 2D linear PE wear-rate of the Reflection liner (n = 68) was 0.23 mm/year, with a mean total wear of 3.14 mm (1.04-7.36), SD 1.45. The wear-rate of the Duraloc 300 cups (n = 32) was 0.14 mm/year, with a mean total wear of 1.84 mm (0.55-4.63), SD 1.07. The difference in PE wear-rate as well as mean total wear was highly significant (p = 0.0001). There was a positive correlation between wear-rate and both Oxford Hip Score and Harris Hip Score (p = 0.02). Large acetabular cup size (>54 mm), HA coating on the stem and age <50 years did not influence PE wear. The higher wear-rate in the Reflection liners could be related to the EtO sterilisation. Intermediate and long-term follow-up is advisable.
    Hip international: the journal of clinical and experimental research on hip pathology and therapy 07/2014; DOI:10.5301/hipint.5000157 · 0.76 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Total hip arthroplasty (THA) is one of the most successful surgical interventions devised in modern times. Attempts to change the current THA procedure with unproven innovations bring the risk of increased failure rates while trying to improve the benefit of the surgery. This manuscript examines the evolution of THA at the Rothman Institute illustrating the key elements that lead the success of this procedure at this institution. These key elements include femoral stem design, use of highly crossed-linked polyethylene and use of pain and rehabilitation protocols. We attempted to describe the long-term results regarding safety, effectiveness, and durability of specific THA implant designs used at this institution drawing on reported evidence in the literature. The authors performed a review of peer-reviewed articles related to the Rothman Institute's experience with THA. Total hip arthroplasty is an efficient, safe, and durable procedure. It is a highly successful operation to restore function and improve pain. The survivorship of THA procedures at the Rothman Institute is higher than 99% at 10 years based on mechanical failure. The use of collarless, tapered wedge femoral stem, highly crossed-linked polyethylene, and improved pain rehabilitation protocols have contributed to this success. There is a well-documented long-term survivorship after THA. Future innovation in THA should address new challenges with younger and more demanding patients, rather than change current methods that have a proven good survivorship. This innovation depends mainly upon improvements in the bearing surfaces and advances in pain control and rehabilitation.
    HSS Journal 07/2012; 8(2):146-50. DOI:10.1007/s11420-012-9268-x
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Polyethylene wear-induced osteolysis constitutes the most severe long-term complication of total hip arthroplasties (THA). Our aim was to assess through MRI the severity and growth pattern of osteolysis, as well as the influence clinical-radiographic variables exert. We analyzed 75 THA with an average evolution time of 13.67years. The implant was a titanium alloy, non-cemented, multiple-hole model with hydroxyapatite coating. Osteolysis was found with a peripheral pattern in 48 and a central pattern in 6; in 52 cases it was continuous, and in 4, isolated. Out of 118 screws, 20 exhibited lysis. There was a proportional correlation between osteolysis severity and wear rate with age, physical activity and acetabular abduction, as well as an association between said variables and peripheral and continuous patterns.
    The Journal of Arthroplasty 05/2014; 29(10). DOI:10.1016/j.arth.2014.05.020 · 2.37 Impact Factor

Preview

Download
0 Downloads
Available from