Frequency of Fetal Heart Rate Categories and Short-Term Neonatal Outcome

Department of Obstetrics and Gynecology, University of Utah, Salt Lake City, Utah, United States
Obstetrics and Gynecology (Impact Factor: 5.18). 09/2011; 118(4):803-8. DOI: 10.1097/AOG.0b013e31822f1b50
Source: PubMed

ABSTRACT To estimate the time spent in each fetal heart rate category during labor and during the last 2 hours before delivery in term singleton pregnancy and to estimate the relationship between the time spent in each category and short-term neonatal outcomes.
This study reviewed fetal heart rate data and newborn outcomes of women in term labor in 10 hospitals over 28 months. Fetal heart rate characteristics were assessed by labor and delivery nurses, and categories were assigned by computer using definitions from the Eunice Kennedy Shriver National Institute of Child Health and Human Development. The duration of time in each category was calculated and correlated with newborn outcome.
Forty-eight thousand four hundred forty-four patients were identified. Considering all of labor, category I was present 77.9% of the time, category II was present 22.1% of the time, and category III was present 0.004% of the time. In the last 2 hours before delivery, category I decreased to 60.9% of the duration, category II increased to 39.1%, and category III increased to 0.006%. Newborns of women whose last 2 hours were exclusively category I did well; only 0.6% had 5-minute Apgar scores less than 7, and 0.2% had low Apgar scores with neonatal intensive care unit (NICU) admission. When more than 75% of the last 2 hours was category II, low 5-minute Apgar score increased to 1.3% of patients, and low 5-minute Apgar score with NICU admission increased to 0.7% (both P<.001).
Category I and category II fetal heart rate patterns are common in labor, and category III patterns are rare. Increasing time in category II in the last 2 hours of labor is associated with increased short-term newborn morbidity.

33 Reads
  • [Show abstract] [Hide abstract]
    ABSTRACT: The objective of this study was to estimate the predictive ability of electronic fetal monitoring (EFM) patterns immediately prior to delivery for acidemia at term birth. This was a 4-year retrospective cohort study of 5388 consecutive singleton, nonanomalous gestations of 37 weeks or longer. The primary exposure was the EFM pattern in the 30 minutes preceding delivery. EFM patterns were prospectively interpreted using Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD) nomenclature as well as non-NICHD measurements of decelerations. The primary outcome was umbilical cord arterial pH of 7.10 or less. Four NICHD-defined EFM features within the 30 minutes prior to birth demonstrated the greatest association with acidemia: repetitive prolonged decelerations (area under the curve [AUC] 0.81), baseline tachycardia (AUC 0.80), repetitive variable decelerations (AUC 0.79), and repetitive late decelerations (0.78) after adjusting for nulliparity, fever, prolonged first stage, and obesity. A non-NICHD measure, total deceleration area, demonstrated superior predictive ability for acidemia (AUC 0.83, P = .04). A non-NICHD measure of deceleration frequency and severity in the second stage performed superior to 4 NICHD EFM features for predicting fetal acidemia.
    American journal of obstetrics and gynecology 09/2012; 207(3):206.e1-8. DOI:10.1016/j.ajog.2012.06.046 · 4.70 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Some intrapartum care practices promote vaginal birth, whereas others may increase the risk for cesarean section. Electronic fetal monitoring and use of the Friedman graph to plot and monitor labor progress are associated with increasing the cesarean section rate. Continuous one-to-one support and midwifery management are associated with lower cesarean section rates. This article reviews the evidence that links specific intrapartum care practices to cesarean section. Strategies that can be implemented in the current social and cultural setting of obstetrics today are recommended.
    Seminars in perinatology 10/2012; 36(5):357-64. DOI:10.1053/j.semperi.2012.04.020 · 2.68 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Objective: To evaluate the interobserver reliability of fetal heart rate (FHR) pattern definition and interpretation assessed by physicians at various levels of training using standard Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD) definitions and standard principles of interpretation. Study design: We conducted an interrater reliability study of the intrapartum FHR tracings of 32 singleton term pregnancies at Los Angeles County-University of Southern California (LAC + USC) Medical Center. Analysis included the 5 hours immediately preceding delivery, divided into 10- minute segments. A medical student, resident, and three attending physicians evaluated the same set of FHR tracings. Interobserver agreement was assessed using the free-marginal kappa coefficient. Results: Reviewers demonstrated substantial to excellent agreement on baseline rate (κ = 0.97), moderate variability (κ = 0.80), accelerations (κ = 0.62), decelerations (κ = 0.63), category (κ = 0.68), and the ability to identify the presence of either moderate variability or accelerations (κ = 0.82). Conclusions: Interobserver agreement was significantly higher on all components of FHR definition and interpretation than previously expected. Standardization of FHR definitions and interpretation may improve interobserver reliability and patient safety.
    American Journal of Perinatology 11/2012; 30(6). DOI:10.1055/s-0032-1326991 · 1.91 Impact Factor
Show more


33 Reads
Available from