Article

Identification of muscle necrosis in the mdx mouse model of Duchenne muscular dystrophy using three-dimensional optical coherence tomography

The University of Western Australia, School of Electrical, Electronic and Computer Engineering, Optical+Biomedical Engineering Laboratory, M018, 35 Stirling Highway, Crawley, Western Australia 6009, Australia.
Journal of Biomedical Optics (Impact Factor: 2.75). 07/2011; 16(7):076013. DOI: 10.1117/1.3598842
Source: PubMed

ABSTRACT Three-dimensional optical coherence tomography (3D-OCT) was used to image the structure and pathology of skeletal muscle tissue from the treadmill-exercised mdx mouse model of human Duchenne muscular dystrophy. Optical coherence tomography (OCT) images of excised muscle samples were compared with co-registered hematoxylin and eosin-stained and Evans blue dye fluorescence histology. We show, for the first time, structural 3D-OCT images of skeletal muscle dystropathology well correlated with co-located histology. OCT could identify morphological features of interest and necrotic lesions within the muscle tissue samples based on intrinsic optical contrast. These findings demonstrate the utility of 3D-OCT for the evaluation of small-animal skeletal muscle morphology and pathology, particularly for studies of mouse models of muscular dystrophy.

Download full-text

Full-text

Available from: Miranda D Grounds, Jul 28, 2015
0 Followers
 · 
138 Views
  • Source
    • "The OCT system used for generating three-dimensional data for imaging and attenuation measurement has been previously described [34]. The custom-built time-domain OCT scanner has a source center wavelength of 1320 nm and a 3-dB bandwidth of 154 nm (DenseLight Semiconductors, Singapore). "
    [Show abstract] [Hide abstract]
    ABSTRACT: We report the use of optical coherence tomography (OCT) to determine spatially localized optical attenuation coefficients of human axillary lymph nodes and their use to generate parametric images of lymphoid tissue. 3D-OCT images were obtained from excised lymph nodes and optical attenuation coefficients were extracted assuming a single scattering model of OCT. We present the measured attenuation coefficients for several tissue regions in benign and reactive lymph nodes, as identified by histopathology. We show parametric images of the measured attenuation coefficients as well as segmented images of tissue type based on thresholding of the attenuation coefficient values. Comparison to histology demonstrates the enhancement of contrast in parametric images relative to OCT images. This enhancement is a step towards the use of OCT for in situ assessment of lymph nodes.
    Biomedical Optics Express 02/2012; 3(2):366-79. DOI:10.1364/BOE.3.000366 · 3.50 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Abnormal changes in orientation of myofibers are associated with various cardiac diseases such as arrhythmia, irregular contraction, and cardiomyopathy. To extract fiber information, we present a method of quantifying fiber orientation and reconstructing three-dimensional tractography of myofibers using optical coherence tomography (OCT). A gradient based algorithm was developed to quantify fiber orientation in three dimensions and particle filtering technique was employed to track myofibers. Prior to image processing, three-dimensional image data set were acquired from all cardiac chambers and ventricular septum of swine hearts using OCT system without optical clearing. The algorithm was validated through rotation test and comparison with manual measurements. The experimental results demonstrate that we are able to visualize three-dimensional fiber tractography in myocardium tissues.
    Biomedical Optics Express 10/2013; 4(10):2150-65. DOI:10.1364/BOE.4.002150 · 3.50 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Introduction: The ability to view individual myofibers is possible with many histological techniques, but not yet with standard in vivo imaging. Optical coherence tomography (OCT) is an emerging technology that can generate high resolution 1-10 μm cross-sectional imaging of tissue in vivo and in real time. Methods: We used OCT to determine architectural differences of tibialis anterior muscles in situ from healthy mice (wild-type [WT], n = 4) and dystrophic mice (mdx, n = 4). After diffusion tensor imaging (DTI) and OCT, muscles were harvested, snap-frozen, and sectioned for staining with wheat germ agglutinin. Results: DTI suggested differences in pennation and OCT was used to confirm this supposition. OCT indicated a shorter intramuscular tendon (WT/mdx ratio of 1.2) and an 18% higher degree of pennation in mdx. Staining confirmed these architectural changes. Conclusions: Architectural changes in mdx muscles, which could contribute to reduction of force, are detectable with OCT. Muscle Nerve, 2013.
    Muscle & Nerve 04/2013; DOI:10.1002/mus.23711 · 2.31 Impact Factor
Show more