Evaluation of Respiratory Motion Effect on Defect Detection in Myocardial Perfusion SPECT: A Simulation Study

Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan.
IEEE Transactions on Nuclear Science (Impact Factor: 1.28). 06/2009; 56(3):671-676. DOI: 10.1109/TNS.2009.2015446
Source: PubMed


The objective of this study is to investigate the effects of respiratory motion (RM) on defect detection in Tc-99m sestamibi myocardial perfusion SPECT (MPS) using a phantom population that includes patient variability. Three RM patterns are included, namely breath-hold, slightly enhanced normal breathing, and deep breathing. For each RM pattern, six 4-D NCAT phantoms were generated, each with anatomical variations. Anterior, lateral and inferior myocardial defects with different sizes and contrasts were inserted. Noise-free SPECT projections were simulated using an analytical projector. Poisson noise was then added to generate noisy realizations. The projection data were reconstructed using the OS-EM algorithm with 1 and 4 subsets/iteration and at 1, 2, 3, 5, 7, and 10 iterations. Short-axis images centered at the centroid of the myocardial defect were extracted, and the channelized Hotelling observer (CHO) was applied for the detection of the defect. The CHO results show that the value of the area under the receiver operating characteristics (ROC) curve (AUC) is affected by the RM amplitude. For all the defect sizes and contrasts studied, the highest or optimal AUC values indicate maximum detectability decrease with the increase of the RM amplitude. With no respiration, the ranking of the optimal AUC value in decreasing order is anterior then lateral, and finally inferior defects. The AUC value of the lateral defect drops more severely as the RM amplitude increases compared to other defect locations. Furthermore, as the RM amplitude increases, the AUC values of the smaller defects drop more quickly than the larger ones. We demonstrated that RM affects defect detectability of MPS imaging. The results indicate that developments of optimal data acquisition methods and RM correction methods are needed to improve the defect detectability in MPS.

Download full-text


Available from: Jyh-Cheng Chen,
  • [Show abstract] [Hide abstract]
    ABSTRACT: The complex interfaces created by migration not only challenge core beliefs about the purpose of career guidance and counseling but also about the precise nature and level of the support required for migrants. However, the issue has had little academic attention. While traditional theories informing the practice of career guidance and counseling implicitly reflect a commitment to social equality, they were developed in relatively homogenous Western capitalist contexts that were strongly individualized, masculine, secular, action and future focused. As career guidance and counseling services in more individualized countries seek to meet the needs of a growing number of clients from more collectivist cultures, the universal relevance of such models is increasingly open to challenge. This article explores three core challenges posed by migration for the theory and practice of career guidance and counseling. The first relates to the very purpose of these types of services for migrants; the second, to the way in which migration requires a realignment of the relationship of theory with practice; and the third relates to the need to redefine service delivery models for this client group. The extent to which notions of “quality” in services are culturally dependent will also be considered, together with the potential for general service improvements being stimulated by the provision of high quality services for migrants.
    Journal of Vocational Behavior 06/2011; 78(3):325-333. DOI:10.1016/j.jvb.2011.03.012 · 2.59 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: To better understand fundamental issues, perception studies of the fusion display would best be performed with a panel of lesions of variable location, size, intensity, and background. There are compelling reasons to use synthetic images that contain artificial lesions for perception research. A consideration of how to obtain this panel of lesions is the nucleus of the present review. This article is a conjoint effort of 3 groups that have joined together to review results from work that they and others have performed. The techniques we review include (1) substitution of lesions into a preexisting image matrix (either using actual prior patient-derived lesions or mathematically modeled artificial lesions), (2) addition of images (either in the attenuation-corrected image space or at an earlier stage before image reconstruction), and (3) simulation of the entire patient image. A judicious combination of the techniques discussed in this review may represent the most efficient pathway of simulating statistically varied but realistic appearing lesions.
    Seminars in nuclear medicine 11/2011; 41(6):437-48. DOI:10.1053/j.semnuclmed.2011.06.007 · 3.34 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modeling onto the 1D vectors corresponding to image frames obtained in summed profiles. To evaluate our method, physical sources and NCAT phantom were intentionally moved 1, 2 and 3 pixels at early, mid and late stages of data acquisition. The full width at half maximum (FWHM) values, the maximum count in the reconstructed image of physical sources, and maximum count in the myocardial wall in 360o view from cardiac perspective were compared with motion-free condition before and after motion correction. Results: Depending on the amount of motion and time of motion occurrence, the FWHM of point source changed from 5.56% to 37.49% compared to the motion-free condition while the relative change of FWHM for these sources changed from 0.8% to 1.84% after correction. The observed changes for maximum count in reconstructed images of point sources were from 1.91% - 21.33% which decreased to 0.13%-0.76% after motion correction. The corresponding changes for extended sources were 1.09%- 21.76% which reduced to 0.06%-0.45% after applying motion correction. In addition, the results showed that the distribution of radioactivity in the cardiac wall for the corrected image are very similar to the real values while the same values in the reconstructed image significantly differed from the original in which motion occurred during imaging. Conclusion: Our method detected and corrected cardiac motion during SPECT imaging through curve fitting of a polynomial onto the 1D vector values corresponding to image frames. Therefore, image misinterpretation can be avoided by correcting motion artifacts.
    Journal of Mazandaran University of Medical Sciences 01/2013; 22(96-96):8-20.
Show more