Article

Measurement of absolute arterial cerebral blood volume in human brain without using a contrast agent

The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.
NMR in Biomedicine (Impact Factor: 3.56). 12/2011; 24(10):1313-25. DOI: 10.1002/nbm.1693
Source: PubMed

ABSTRACT Arterial cerebral blood volume (CBV(a) ) is a vital indicator of tissue perfusion and vascular reactivity. We extended the recently developed inflow vascular-space-occupancy (iVASO) MRI technique, which uses spatially selective inversion to suppress the signal from blood flowing into a slice, with a control scan to measure absolute CBV(a) using cerebrospinal fluid (CSF) for signal normalization. Images were acquired at multiple blood nulling times to account for the heterogeneity of arterial transit times across the brain, from which both CBV(a) and arterial transit times were quantified. Arteriolar CBV(a) was determined separately by incorporating velocity-dependent bipolar crusher gradients. Gray matter (GM) CBV(a) values (n=11) were 2.04 ± 0.27 and 0.76 ± 0.17 ml blood/100 ml tissue without and with crusher gradients (b=1.8 s/mm(2) ), respectively. Arterial transit times were 671 ± 43 and 785 ± 69 ms, respectively. The arterial origin of the signal was validated by measuring its T(2) , which was within the arterial range. The proposed approach does not require exogenous contrast agent administration, and provides a non-invasive alternative to existing blood volume techniques for mapping absolute CBV(a) in studies of brain physiology and neurovascular diseases.

Download full-text

Full-text

Available from: Jun Hua, Jul 06, 2014
1 Follower
 · 
104 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: The relationship between cerebral blood volume (CBV) and cerebral blood flow (CBF) underlies blood oxygenation level-dependent functional MRI signal. This study investigates the potential for improved characterization of the CBV-CBF relationship in humans, and examines sex effects as well as spatial variations in the CBV-CBF relationship. Healthy subjects were imaged noninvasively at rest and during visual stimulation, constituting the first MRI measurement of the absolute CBV-CBF relationship in humans with complete coverage of the functional areas of interest. CBV and CBF estimates were consistent with the literature, and their relationship varied both spatially and with sex. In a region of interest with stimulus-induced activation in CBV and CBF at a significance level of the P < 0.05, a power function fit resulted in CBV = 2.1 CBF(0.32) across all subjects, CBV = 0.8 CBF(0.51) in females and CBV = 4.4 CBF(0.15) in males. Exponents decreased in both sexes as ROIs were expanded to include less significantly activated regions. Consideration for potential sex-related differences, as well as regional variations under a range of physiological states, may reconcile some of the variation across literature and advance our understanding of the underlying cerebrovascular physiology. Magn Reson Med, 2013. © 2013 Wiley Periodicals, Inc.
    Magnetic Resonance in Medicine 09/2014; 72(3). DOI:10.1002/mrm.24984 · 3.40 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: In addition to the BOLD scan, quantitative functional MRI studies require measurement of both cerebral blood volume (CBV) and flow (CBF) dynamics. The ability to detect CBV and CBF responses in a single additional scan would shorten the total scan time and reduce temporal variations. Several approaches for simultaneous CBV and CBF measurement during functional MRI experiments have been proposed in two-dimensional (2D) mode covering one to three slices in one repetition time (TR). Here, we extended the principles from previous work and present a three-dimensional (3D) whole-brain MRI approach that combines the vascular-space-occupancy (VASO) and flow-sensitive alternating inversion recovery (FAIR) arterial spin labeling (ASL) techniques, allowing the measurement of CBV and CBF dynamics, respectively, in a single scan. 3D acquisitions are complicated for such a scan combination as the time to null blood signal during a steady state needs to be known. We estimated this using Bloch simulations and demonstrate that the resulting 3D acquisition can detect activation patterns and relative signal changes of quality comparable to that of the original separate scans. The same was found for temporal signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). This approach provides improved acquisition efficiency when both CBV and CBF responses need to be monitored during a functional task.
    NeuroImage 08/2014; 103. DOI:10.1016/j.neuroimage.2014.08.025 · 6.13 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: PurposeNeurovascular regulation, including responses to neural activation that give rise to the blood oxygenation level–dependent (BOLD) effect, occurs mainly at the arterial and arteriolar level. The purpose of this study is to develop a framework for fast imaging of arterial cerebral blood volume (aCBV) signal suitable for functional imaging studies.MethodsA variant of the pseudocontinuous arterial spin tagging technique was developed in order to achieve a contrast that depends on aCBV with little contamination from perfusion signal by taking advantage of the kinetics of the tag through the vasculature. This technique tailors the tagging duration and repetition time for each subject. The proposed technique, called AVAST, is compared empirically with BOLD imaging and standard (perfusion-weighted) arterial spin labeling (ASL) technique, in a motor-visual activation paradigm.ResultsThe average Z-scores in the activated area obtained over all the subjects were 4.25, 5.52, and 7.87 for standard ASL, AVAST, and BOLD techniques, respectively. The aCBV contrast obtained from AVAST provided 80% higher average signal-to-noise ratio and 95% higher average contrast-to-noise ratio compared with that of the standard ASL measurements.ConclusionAVAST exhibits improved activation detection sensitivity and temporal resolution over the standard ASL technique, in functional MRI experiments, while preserving its quantitative nature and statistical advantages. AVAST particularly could be useful in clinical studies of pathological conditions, longitudinal studies of cognitive function, and studies requiring sustained periods of the condition. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.
    Magnetic Resonance in Medicine 04/2014; 73(3). DOI:10.1002/mrm.25220 · 3.40 Impact Factor