Article

In vivo imaging of the microcirculation of the volar forearm using correlation mapping optical coherence tomography (OCT)

Biomedical Optics Express (Impact Factor: 3.5). 05/2011; 2(5):1184-93. DOI: 10.1364/BOE.2.001184
Source: PubMed

ABSTRACT Correlation mapping optical coherence tomography (cmOCT) is a recently proposed technique that extends the capabilities of OCT to enable mapping of vasculature networks. The technique is achieved as a processing step on OCT intensity images that does not require any modification to existing OCT hardware. In this paper we apply the cmOCT processing technique to in vivo human imaging of the volar forearm. We illustrate that cmOCT can produce maps of the microcirculation that clearly follow the accepted anatomical structure. We demonstrate that the technique can extract parameters such as capillary density and vessel diameter. These parameters are key clinical markers for the early changes associated with microvascular diseases. Overall the presented results show that cmOCT is a powerful new tool that generates microcirculation maps in a safe non-invasive, non-contact technique which has clear clinical applications.

1 Follower
 · 
201 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: To demonstrate optical coherence tomography for high-resolution, noninvasive imaging of the human retina. Optical coherence tomography is a new imaging technique analogous to ultrasound B scan that can provide cross-sectional images of the retina with micrometer-scale resolution. Survey optical coherence tomographic examination of the retina, including the macula and optic nerve head in normal human subjects. Research laboratory. Convenience sample of normal human subjects. Correlation of optical coherence retinal tomographs with known normal retinal anatomy. Optical coherence tomographs can discriminate the cross-sectional morphologic features of the fovea and optic disc, the layered structure of the retina, and normal anatomic variations in retinal and retinal nerve fiber layer thicknesses with 10-microns depth resolution. Optical coherence tomography is a potentially useful technique for high depth resolution, cross-sectional examination of the fundus.
    Archives of Ophthalmology 04/1995; 113(3):325-32. DOI:10.1001/archopht.1995.01100030081025 · 4.49 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The editors introduce the Biomedical Optics Express feature issue, "In Vivo Microcirculation Imaging," which includes 14 contributions from the biomedical optics community, covering such imaging techniques as optical coherence tomography, photoacoustic microscopy, laser Doppler /speckle imaging, and near infrared spectroscopy and fluorescence imaging.
    Biomedical Optics Express 07/2011; 2(7):1861-3. DOI:10.1364/BOE.2.001861 · 3.50 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: This paper presents comprehensive and depth-resolved retinal microvasculature images within human retina achieved by a newly developed ultrahigh sensitive optical microangiography (UHS-OMAG) system. Due to its high flow sensitivity, UHS-OMAG is much more sensitive to tissue motion due to the involuntary movement of the human eye and head compared to the traditional OMAG system. To mitigate these motion artifacts on final imaging results, we propose a new phase compensation algorithm in which the traditional phase-compensation algorithm is repeatedly used to efficiently minimize the motion artifacts. Comparatively, this new algorithm demonstrates at least 8 to 25 times higher motion tolerability, critical for the UHS-OMAG system to achieve retinal microvasculature images with high quality. Furthermore, the new UHS-OMAG system employs a high speed line scan CMOS camera (240 kHz A-line scan rate) to capture 500 A-lines for one B-frame at a 400 Hz frame rate. With this system, we performed a series of in vivo experiments to visualize the retinal microvasculature in humans. Two featured imaging protocols are utilized. The first is of the low lateral resolution (16 μm) and a wide field of view (4 × 3 mm(2) with single scan and 7 × 8 mm(2) for multiple scans), while the second is of the high lateral resolution (5 μm) and a narrow field of view (1.5 × 1.2 mm(2) with single scan). The great imaging performance delivered by our system suggests that UHS-OMAG can be a promising noninvasive alternative to the current clinical retinal microvasculature imaging techniques for the diagnosis of eye diseases with significant vascular involvement, such as diabetic retinopathy and age-related macular degeneration.
    Journal of Biomedical Optics 10/2011; 16(10):106013. DOI:10.1117/1.3642638 · 2.75 Impact Factor
Show more

Preview (2 Sources)

Download
3 Downloads
Available from