Article

Design of isoplanatic aspheric monofocal intraocular lenses.

Instituto de Optica, Consejo Superior de Investigaciones Científicas (CSIC), Madrid, Spain.
Optics Express (Impact Factor: 3.53). 03/2011; 19(7):6215-30. DOI: 10.1364/OE.19.006215
Source: PubMed

ABSTRACT A new and complete methodology of monofocal intraocular lens (IOL) design is presented aiming at isoplanatism, i.e. IOLs that provide the eye with optimized optical quality over a wide field of view (typically in a range of ten degrees). The methodology uses a merit function considering dimensional and biomechanical constraints, and a geometrical optical quality metric that is evaluated simultaneously at different field angles. As an example, we present new isoplanatic designs based on different commercial IOL platforms. Aspheric isoplanatic designs improve peripheral quality over current aspheric IOLs. Also, isoplanatic designs provide more stable optical quality across the field and across pupil diameter.

1 Bookmark
 · 
134 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: A widespread type of multifocal intraocular lens (MIOL) is based on expanding the depth of focus with specific amounts of spherical aberration. However, knowing the optimal wavefront aberration for multifocality does not directly provide a MIOL geometry. To overcome this issue, we present a new strategy to design MIOLs. The method optimizes directly the IOL surface geometries (aspheres with aspherical coefficients up to tenth order) using a multisurface pseudophakic eye model and a multiconfiguration approach, where the merit function jointly considers the optical quality at different object plane locations. An example of MIOL [22 diopters (D) far distance correction] was designed. For this design, the ocular modulator transfer function (MTF) at 50 cycles per millimeter remained above 0.47 for all object locations. The design provides high optical quality performance for far and intermediate distances and peak optical performance at near distances (MTF>0.57). Additionally, the design shows good performance against pupil changes (3-5 mm pupil diameter range). Finally, when the MIOL was tested on pseudophakic eye models with corneal spherical aberrations within a typical population range, the high multifocal performance was maintained in almost 40% of potential patients (ignoring asymmetric aberrations effects).
    Optics Letters 12/2013; 38(24):5303-6. DOI:10.1364/OL.38.005303 · 3.39 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: To quantify 3-dimensionally the anterior segment geometry, biometry, and lens position and alignment in patients before and after implantation of the Crystalens-AO (Bausch & Lomb, Rochester, NY) accommodating intraocular lens (A-IOL). Prospective, observational study. Ten patients (20 eyes) with cataract before and after implantation of the Crystalens-AO A-IOL. Custom full anterior segment 3-dimensional (3-D) spectral optical coherence tomography (OCT) provided with quantification tools was used to image the cornea, iris, and natural lens preoperatively and intraocular lens postoperatively. Measurements were obtained under phenylephrine preoperatively and under natural viewing conditions and phenylephrine (for accommodative efforts ranging from 0 to 2.5 diopters [D]) and pilocarpine postoperatively. Three-dimensional quantitative anterior segment images, corneal geometry and power, anterior chamber depth (ACD), lens thickness, pupil diameter, A-IOL shift with accommodative effort or drug-induced accommodation, and A-IOL alignment. Crystalline lens and IOLs were visualized and quantified 3-dimensionally. The average ACD were 2.64±0.24 and 3.65±0.35 mm preoperatively and postoperatively (relaxed state), respectively, and they were statistically significantly correlated (although their difference was not statistically correlated with lens thickness). The A-IOL did not shift systematically with accommodative effort, with 9 lenses moving forward and 11 lenses moving backward (under natural conditions). The average A-IOL shift under stimulated accommodation with pilocarpine was -0.02±0.20 mm. The greatest forward shift occurred bilaterally in 1 patient (-0.49 mm in the right eye and -0.52 mm in the left eye, under pilocarpine). The high right/left symmetry in the horizontal tilt of the crystalline lens is disrupted on IOL implantation. Accommodative IOLs tend to be slightly more vertically tilted than the crystalline lens, with increasing tendency with accommodative effort. Two subjects showed postoperative IOL tilts >9 degrees. Changes in pupillary diameter correlated with pilocarpine-induced A-IOL axial shift. Intermediate accommodative demands (1.25 D) elicited the greater shifts in axial A-IOL location and tilt and pupil diameter. Quantitative 3-D anterior segment OCT allows full evaluation of the geometry of eyes implanted with A-IOLs preoperatively and postoperatively. High-resolution OCT measurements of the Crystalens 3-D positioning revealed small (and in many patients backward) A-IOL axial shifts with both natural or drug-induced accommodation, as well as tilt changes with respect to natural lens and accommodative effort. Proprietary or commercial disclosure may be found after the references.
    Ophthalmology 08/2013; 121(1). DOI:10.1016/j.ophtha.2013.06.025 · 5.56 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The design of customized biomedical devices is certainly relevant nowadays, and to achieve higher implantation accuracy, custom-made implants need to be developed. The aim of this work is to present an integrated tool for the design of a tracheal stent to meet the most important requirements or needs of physicians, hospital administrators and patients. The methodology is based on the synergy between several methods such as attribute listing, quality function deployment (QFD), and the theory of inventive problem solving (TRIZ), for solving physical contradictions related to geometry and material. The result is a stent shape approved by physicians. Moreover, a parameterization tool was used to modify the stent’s general dimensions to fit a specific patient. Lastly, the final conceptual design was printed using an additive manufacturing technology known as Fab@Home.
    Computer-Aided Design 12/2012; 44(12):1173–1181. DOI:10.1016/j.cad.2012.07.004 · 1.52 Impact Factor

Full-text (5 Sources)

Download
299 Downloads
Available from
May 23, 2014