The effect of alterations on resorbable blasting media processed implant surfaces on early bone healing: a study in rabbits.
Department of Dentistry, Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil.
Journal Article: Implant dentistry (impact factor: 1.51). 04/2011; 20(2):167-77. DOI: 10.1097/ID.0b013e318211fb32
Abstract
Screw-root form implant surfaces were treated with 1 of 3 methods: grit (alumina) blasted/acid etching, RM, and RM + acid etching (RMAA). Surface topography (n = 3 each) was characterized by scanning electron microscopy and atomic force microscopy and chemical characterization by x-ray photoelectron spectroscopy analysis. The implants were placed at the distal femur of 16 rabbits, where 3 implants, 1 from each surface, were placed bilaterally remaining 4 and 8 weeks in vivo. After euthanization, one half of the specimens were torqued to interface failure at a rate of ∼0.196 radians/min and the other half were nondecalcified processed for histomorphology and bone-to-implant contact evaluation.
Physicochemical characterization showed that the grit (alumina) blasted/acid-etched surface was rougher than RM and RMAA. Higher levels of calcium and phosphorous were observed for the RM surface compared with the RMAA surface. No significant differences were observed in torque and bone-to-implant contact between surfaces at 4 or 8 weeks. Histomorphologic evaluation showed woven bone formation around all surfaces at 4 weeks, and its initial replacement by lamellar bone at 8 weeks.
Despite differences in texture/chemistry, all implant surfaces were biocompatible and osseoconductive, and led to comparable in vivo bone fixation and measurable histomorphometric parameters.
Source: PubMed
Comments on this publication
ResearchGate members can add comments. Sign up now and post your comment!
Similar publications
Biomechanical and histomorphometric analysis of etched and non-etched resorbable blasting media processed implant surfaces: an experimental study in dogs.
Journal of the mechanical behavior of biomedical materials. 3(5):382-91.
Biomechanical and Bone Histomorphological Evaluation of Two Surfaces on Tapered and Cylindrical Root Form Implants: An Experimental Study in Dogs.
Clinical implant dentistry and related research.
Bone responses to simvastatin-loaded porous implant surfaces in an ovariectomized model.
The International journal of oral & maxillofacial implants. 27(2):369-74.
The osteoinductivity of silicate-substituted calcium phosphate.
The Journal of bone and joint surgery. American volume. 93(23):2219-26.
Data provided are for informational purposes only. Although carefully collected, accuracy cannot be guaranteed. The impact factor represents a rough estimation of the journal's impact factor and does not reflect the actual current impact factor. Publisher conditions are provided by RoMEO. Differing provisions from the publisher's actual policy or licence agreement may be applicable.
Science & Research Jobs
Several PhD Fellowships/Positions in Life Sciences
Position: Phd Program
Employer: University of Kaiserslautern
Consumer Lifestyle-Senior product develop engineer
Position: Engineer
Employer: Philips (China) Investment Co.,Ltd