Article

Impaired lung function after intubation and mechanical ventilation for surgical ligation of the ductus arteriosus in preterm infants.

Department of Perinatal Medicine, Hopital Jeanne de Flandre, CHRU de Lille, Lille, France.
Journal of cardiothoracic and vascular anesthesia (impact factor: 1.06). 03/2011; 25(6):1000-4. DOI:10.1053/j.jvca.2011.01.010 pp.1000-4
Source: PubMed

ABSTRACT Significant patent ductus arteriosus (PDA) in the preterm infant has been associated with pulmonary edema and impaired gas exchange. Therefore, surgical ligature of the DA may be required. However, the effects of intubation and mechanical ventilation on the PDA-induced lung dysfunction presently are unknown. The aim of the study was to investigate whether intubation and mechanical ventilation alter pulmonary function in the preterm infant with significant PDA.
A prospective study.
The neonatal intensive care unit and department of anesthesiology in a university hospital.
Preterm infants <32 weeks' gestational age treated with nasal continuous positive airway pressure (NCPAP) and requiring mechanical ventilation for undergoing surgical DA ligature.
Respiratory, Doppler echocardiographic parameters, and chest x-ray transparencies of the lungs were measured during NCPAP and 2 hours after intubation and starting mechanical ventilation.
Twenty preterm infants (gestational age = 27 ± 1 wk, birth weight = 950 ± 140 g) were included. Heart rate, O(2) need, PaCO(2), and plasma lactate concentrations were significantly higher after intubation. The mean oxygenation index increased from 1.5 ± 0.6 to 7.2 ± 3 (p < 0.05). The overall transparencies of the lungs decreased after intubation. DA diameter, shortening fraction of the left ventricle, left pulmonary artery blood flow velocities, and left atrium/aorta did not change.
In preterm infants with significant PDA, intubation and mechanical ventilation before surgical DA ligation may increase the O(2) need and PaCO(2) and may promote lung edema formation. Mechanical ventilation-induced impairment in lung function is not associated with a change in pulmonary or systemic circulation or DA flow. Special care should be taken to prevent respiratory failure when intubation and mechanical ventilation are required for undergoing surgical DA ligation in the preterm infant.

0 0
 · 
0 Bookmarks
 · 
58 Views

Keywords

2 hours
 
chest x-ray transparencies
 
DA flow
 
Doppler echocardiographic parameters
 
lung edema formation
 
lung function
 
mean oxygenation index
 
Mechanical ventilation-induced impairment
 
nasal continuous positive airway pressure
 
neonatal intensive care unit
 
PDA-induced lung dysfunction
 
plasma lactate concentrations
 
prospective study
 
pulmonary function
 
significant PDA
 
Special care
 
surgical ligature
 
undergoing surgical DA ligation
 
undergoing surgical DA ligature
 
university hospital
 

Thierry Dzukou