Article

A multiparametric evaluation of post-restored teeth with simulated bone loss.

Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan.
Journal of the mechanical behavior of biomedical materials 04/2011; 4(3):322-30. DOI:10.1016/j.jmbbm.2010.10.012
Source: PubMed

ABSTRACT Endodontically-treated teeth are prone to fracture due to loss of tooth structure and altered mechanical behaviors. The stability and rigidity of post-restored teeth, particularly in cases involving periodontal destruction, has not been adequately investigated. This study examined the influence of post material on teeth with simulated bone reduction by a multiparametric evaluation. Sixty extracted premolars of similar sizes were endodontically treated then divided into six groups. Each group was restored with one of the combinations of three posts (a glass-fiber, a prefabricated titanium post, and a cast post) and two simulated bone conditions (2 or 6 mm below crown margins). After crown restorations, they were loaded with a 100 N force then the displacements were examined by the digital-image-correlation technique. Marginal integrity on the buccal and lingual crown margins was examined before and after the thermocycling. Finally, the teeth were loaded until failure to examine the strength and fracture patterns. The digital-image-correlation measurements revealed that tooth deformation was related to the support conditions, especially for the fiber post groups. The cast post groups showed less altered marginal integrity after thermomechanical loading than the fiber and titanium post groups did. In the fracture test, the fiber-post/reduced-support group exhibited inferior fracture strength. The reduced support significantly affected fracture strength and incidence of repairable root fracture. The marginal integrity was not correlated with tooth deformation, since the tooth flexed at the crest of the simulated bone. The root fracture resistance was determined mainly by post materials but was concurrently affected by the support conditions.

0 0
 · 
0 Bookmarks
 · 
42 Views

Keywords

altered marginal integrity
 
cast post
 
cast post groups
 
crown restorations
 
Endodontically-treated teeth
 
fiber post groups
 
fracture test
 
multiparametric evaluation
 
periodontal destruction
 
post-restored teeth
 
posts
 
prefabricated titanium post
 
reduced support
 
root fracture resistance
 
simulated bone conditions
 
simulated bone reduction
 
support conditions
 
titanium post groups
 
tooth flexed
 
tooth structure