Article

How continuous monitoring changes the interaction of patients with a mobile telemedicine system.

Bioengineering and Telemedicine Group, Polytechnic University of Madrid, Madrid, Spain.
Journal of diabetes science and technology 01/2011; 5(1):5-12. DOI: 10.1177/193229681100500102
Source: PubMed

ABSTRACT The combination of telemedicine systems integrating mobile technologies with the use of continuous glucose monitors improves patients' glycemic control but demands a higher interaction with information technology tools that must be assessed. In this article, we analyze patients' behavior from the use-of-the-system point of view, identifying how continuous monitoring may change the interaction of patients with the mobile telemedicine system.
Patients' behavior were evaluated in a clinical experiment consisting of a 2-month crossover randomized study with 10 type 1 diabetes patients. During the entire experiment, patients used the DIABTel telemedicine system, and during the intervention phase, they wore a continuous glucose monitor. Throughout the experiment, all user actions were automatically registered. This article analyzes the occurrence of events and the behavior patterns in blood glucose (BG) self-monitoring and insulin adjustments. A subjective evaluation was also performed based on the answers of the patients to a questionnaire delivered at the end of the study.
The number of sessions established with the mobile Smart Assistant was considerably higher during the intervention period than in the control period (29.0 versus 18.8, p < .05), and it was also higher than the number of Web sessions (29.0 versus 22.2, p < .01). The number of daily boluses was higher during the intervention period than in the control period (5.27 versus 4.40, p < .01). The number of daily BG measurements was also higher during the intervention period (4.68 versus 4.05, p < .05) and, in percentage, patients increased the BG measurements not associated to meals while decreasing the percentage of preprandial measurements. The subjective evaluation shows that patients would recommend the use of DIABTel in routine care.
The use of a continuous glucose monitor changes the way patients manage their diabetes, as observed in the increased number of daily insulin bolus, the increased number of daily BG measurements, and the differences in the distribution of BG measurements throughout the day. Continuous monitoring also increases the interaction of patients with the information system and modifies their patterns of use. We can conclude that mobile technologies are especially useful in scenarios of tight monitoring in diabetes, and they are well accepted by patients.

Full-text

Available from: Gema García-Sáez, Mar 31, 2015

Click to see the full-text of:

Article: How continuous monitoring changes the interaction of patients with a mobile telemedicine system.

2.27 MB

See full-text
0 Bookmarks
 · 
91 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Monitoring glucose concentration in the blood is essential in the therapy of diabetes, a pathology which affects about 350 million people around the World (three million in Italy), causes more than four million deaths per year and consumes a significant portion of the budget of national health systems (10% in Italy). In the last 15 years, several sensors with different degree of invasiveness have been proposed to monitor glycemia in a quasi-continuous way (up to 1 sample/min rate) for relatively long intervals (up to 7 consecutive days). These continuous glucose monitoring (CGM) sensors have opened new scenarios to assess, off-line, the effectiveness of individual patient therapeutic plans from the retrospective analysis of glucose time-series, but have also stimulated the development of innovative on-line applications, such as hypo/hyper-glycemia alert systems and artificial pancreas closed-loop control algorithms. In this review, we illustrate some significant Italian contributions, both from industry and academia, to the growth of the CGM sensors research area. In particular, technological, algorithmic and clinical developments performed in Italy will be discussed and put in relation with the advances obtained in the field in the wider international research community.
    Sensors 12/2012; 12(10):13753-80. DOI:10.3390/s121013753 · 2.05 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Patients with type 1 and type 2 diabetes often find it difficult to control their blood glucose level on a daily basis because of distance or physical incapacity. With the increase in Internet-enabled smartphone use, this problem can be resolved by adopting a mobile diabetes monitoring system. Most existing studies have focused on patients' usability perceptions, whereas little attention has been paid to physicians' intentions to adopt this technology. The aim of the study was to evaluate the perceptions and user acceptance of mobile diabetes monitoring among Japanese physicians. A questionnaire survey of physicians was conducted in Japan. The structured questionnaire was prepared in a context of a mobile diabetes monitoring system that controls blood glucose, weight, physical activity, diet, insulin and medication, and blood pressure. Following a thorough description of mobile diabetes monitoring with a graphical image, questions were asked relating to system quality, information quality, service quality, health improvement, ubiquitous control, privacy and security concerns, perceived value, subjective norms, and intention to use mobile diabetes monitoring. The data were analyzed by partial least squares (PLS) path modeling. In total, 471 physicians participated from 47 prefectures across Japan, of whom 134 were specialized in internal and gastrointestinal medicine. Nine hypotheses were tested with both the total sample and the specialist subsample; results were similar for both samples in terms of statistical significance and the strength of path coefficients. We found that system quality, information quality, and service quality significantly affect overall quality. Overall quality determines the extent to which physicians perceive the value of mobile health monitoring. However, in contrast to our initial predictions, overall quality does not have a significant direct effect on the intention to use mobile diabetes monitoring. With regard to net benefits, both ubiquitous control and health improvement are significant predictors. Net benefits in turn significantly motivate physicians to use mobile health monitoring, and has a strong influence on perceived value. Perceived value and subjective norms are predictors of intention to use. In our sample, concerns over privacy and security risk have no significant effects on intention to use mobile diabetes monitoring. Among the 3 control variables, only age significantly affected intention to use mobile diabetes monitoring, whereas experience and gender were not significant predictors of intention. Physicians consider perceived value and net benefits as the most important motivators to use mobile diabetes monitoring. Overall quality assessment does affect their intention to use this technology, but only indirectly through perceived value. Net benefits seem to be a strong driver in both a direct and indirect manner, implying that physicians may perceive health improvement with ubiquitous control as a true utility by enhancing cost-effective monitoring, and simultaneously recognize it as a way to create value for their clinical practices.
    Journal of Medical Internet Research 11/2012; 14(6):e183. DOI:10.2196/jmir.2159 · 4.67 Impact Factor