ABSTRACT Acute ischemic strokes are associated with poor outcomes and high health care burden. Evidence exists evaluating the use of neurothrombectomy devices in patients receiving currently recommended treatments that may have limited efficacy.
To describe the state of the evidence supporting use of neurothrombectomy devices in the treatment of acute ischemic stroke.
MEDLINE, SCOPUS, the Cochrane Central Register of Controlled Trials, the Cochrane Database of Systematic Reviews, and Web of Science were searched, without language restrictions, from their inception through May 2010. The MEDLINE and Cochrane Central Register of Controlled Trials searches were updated through November 2010.
Two independent investigators screened citations for human studies of any design or case series or case reports of patients with an acute ischemic stroke that evaluated a neurothrombectomy device and reported at least 1 clinical effectiveness outcome or harm.
Using standardized protocols, 2 independent investigators extracted information about study characteristics and outcomes, and a third reviewer resolved disagreement.
87 articles met eligibility criteria, including 18 prospective single-group studies, 7 noncomparative retrospective studies, and 62 case series or case reports. Two U.S. Food and Drug Administration (FDA)-cleared devices, the MERCI Retriever (Concentric Medical, Mountain View, California) (40%) and the Penumbra System (Penumbra, Alameda, California) (9%), represented a large portion of the available data. All prospective and retrospective studies provided data on successful recanalization with widely varying rates (43% to 78% with the MERCI Retriever and 83% to 100% with the Penumbra System). Rates of harms, including symptomatic (16 studies; 0% to 10% with the MERCI Retriever and 0% to 11% with the Penumbra System) or asymptomatic (13 studies; 28% to 43% and 1% to 30%, respectively) intracranial hemorrhage and vessel perforation or dissection (11 studies; 0% to 7% and 0% to 5%, respectively), also varied by device. Predictors of harm included older age, history of stroke, and higher baseline stroke severity scores, whereas successful recanalization was the sole predictor of good outcomes.
Most available data are from single-group, noncomparative studies. In addition, the patient population most likely to benefit from these devices is undetermined.
Currently available neurothrombectomy devices offer intriguing treatment options in patients with acute ischemic stroke. Future trials should use a randomized design, with adequate power to show equivalency or noninferiority between competing strategies or devices, and strive to identify populations that are most likely to benefit from use of neurothrombectomy devices.
Agency for Healthcare Research and Quality.

Download full-text

Full-text

Available from: Craig I Coleman, Feb 05, 2014
3 Followers
 · 
185 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The management of acute ischemic stroke is rapidly developing. Although acute ischemic stroke is a major cause of adult disability and death, the number of patients requiring emergency endovascular intervention remains unknown, but is a fraction of the overall stroke population. Public health initiatives endeavor to raise public awareness about acute stroke to improve triage for emergency treatment, and the medical community is working to develop stroke services at community and academic medical centers throughout the United States. There is an Accreditation Council for Graduate Medical Education-approved pathway for training in endovascular surgical neuroradiology, the specialty designed to train physicians specifically to treat cerebrovascular diseases. 29 Primary and comprehensive stroke center designations have been defined,54 yet questions remain about the best delivery model. Telemedicine is available to help community medical centers cope with the complexity of stroke triage and treatment. 55
    Circulation 06/2011; 123(22):2591-601. DOI:10.1161/CIRCULATIONAHA.110.971564 · 14.95 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Imamura K, Okayasu N, Nagatsu T. The relationship between depression and regional cerebral blood flow in Parkinson’s disease and the effect of selegiline treatment. Acta Neurol Scand: 2011: 124: 28–39. © 2010 John Wiley & Sons A/S.Objectives –  We examined the relationship between severity of depression in Parkinson’s disease (PD) and regional cerebral blood flow (rCBF) using single photon emission computed tomography (SPECT) and the reaction to levodopa-selegiline combination therapy.Materials and methods –  We evaluated 52 patients with PD and nine age-matched controls with SPECT and the Unified Parkinson’s Disease Rating Scale (UPDRS) part III, Mini-Mental State Examination (MMSE), and Beck Depression Inventory (BDI) to evaluate depression severity and its connection with rCBF. Furthermore, we examined rCBF in patients with PD treated with levodopa with or without selegiline.Results –  A significant fall in rCBF was observed in the bilateral posterior cingulate, hippocampus, and cuneus and the superior parietal and primary visual areas in PD patients with minor depression and in all regions in those with major depression. Elevations in UPDRS part III and BDI scores and falls in MMSE scores were of significantly lower magnitude in the levodopa-selegiline group than in the levodopa group. Whole brain rCBF fell significantly less in the levodopa-selegiline group than in the levodopa group.Conclusions –  These results indicate that selegiline controlled not only worsening of motor function and cognitive function in PD but also aggravation of minor depression, and restrained a fall in whole brain rCBF.
    Acta Neurologica Scandinavica 06/2011; 124(1):28 - 39. DOI:10.1111/j.1600-0404.2010.01443.x · 2.44 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: In this study, we propose a new method for enhancement of intraarterial thrombolysis using an ionic polymer-metal composite (IPMC) actuator. The purpose of this study was to test the mechanical thrombolysis efficiency of IPMC actuators and evaluate the endovascular vibrating polymer actuator probe for mechanical thrombolysis in a phantom model; 2 × 1 × 15 mm (2 mm in width, 1 mm in thickness, and 15 mm in length) and 0.8 × 0.8 × 10 mm (0.8 mm in width, 0.8 mm in thickness, and 10 mm in length) IPMC actuators were fabricated by stacking five and four Nafion-117 films, respectively. We manufactured the endovascular vibrating polymer actuator probe, for which thrombolysis efficiency was tested in a vascular phantom. The phantom study using 2 × 1 × 15 mm IPMC actuators showed that 5 Hz actuation is the optimal frequency for thrombolysis under both 2 and 3 V, when blood clot was not treated with rtPA, and when exposed to rtPA, IPMC actuators under the optimized condition (3 V, 5 Hz, and 5 min) significantly increased the thrombolysis degree compared with control and other experimental groups (p < 0.05). In addition, 0.8 × 0.8 × 10 mm IPMC actuators also revealed a significantly higher thrombolysis degree under the optimized condition than the control and rtPA only groups (p < 0.05). Finally, the fabricated probe using 0.8 × 0.8 × 10 mm IPMC actuators also incurred higher thrombolysis degree under the optimized condition than the control and rtPA only groups (p < 0.05). A vibrating polymer actuator probe is a feasible device for intravascular thrombolysis, and further study in an animal model is warranted.
    ASAIO journal (American Society for Artificial Internal Organs: 1992) 07/2011; 57(4):286-92. DOI:10.1097/MAT.0b013e31822188ce · 1.39 Impact Factor