Effects of a calcium phosphate coating on the osseointegration of endosseous implants in a rabbit model.
Department of Implant Dentistry, Università degli studi di Milano, Fondazione IRCCS Ca' Grande, Milano, Italy.
Journal Article: Clinical Oral Implants Research (impact factor: 2.92). 12/2010; 22(7):760-6. DOI: 10.1111/j.1600-0501.2010.02056.x
Abstract
Two hundred and sixteen dental implants were inserted in the tibia and in the femur of 36 rabbits. One hundred and eight were represented by Ca-P oxidized surface implant and other 108 were titanium porous oxide surface modified implants. Each rabbit received six implants. Animals were sacrificed after 2, 4 and 9 weeks of healing. Each group included 12 rabbits. The femoral implant and the proximal implant of the tibia of each animal were subjected to the histologic analysis and the distal implants of the tibia underwent removal torque test (RTQ).
Histological analysis in terms of BIC and RTQ did not revealed any significant difference between the Ca-P oxidized surface and the oxidized surface at 2 and 4 weeks. At 9 weeks, the oxidized surface demonstrated better results in terms of RTQ in the tibia.
In conclusion, findings from the present study suggested that the Ca-P coating had no beneficial effect in improving bonding strength at the bone-implant interface either at 2, 4 and 9 weeks.
Source: PubMed
Comments on this publication
ResearchGate members can add comments. Sign up now and post your comment!
Similar publications
Effect of a macroscopic groove on bone response and implant stability.
Clinical oral implants research. 21(12):1379-85.
Osseointegration of zirconia implants with different surface characteristics: an evaluation in rabbits.
The International journal of oral & maxillofacial implants. 27(2):352-8.
Biomechanical evaluation of the interfacial strength of a chemically modified sandblasted and acid-etched titanium surface.
Journal of biomedical materials research. Part A. 78(2):291-7.
Comparison of Er:YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: a biomechanical and histological analysis in sheep.
Lasers in surgery and medicine. 42(7):652-61.
Data provided are for informational purposes only. Although carefully collected, accuracy cannot be guaranteed. The impact factor represents a rough estimation of the journal's impact factor and does not reflect the actual current impact factor. Publisher conditions are provided by RoMEO. Differing provisions from the publisher's actual policy or licence agreement may be applicable.
Science & Research Jobs
PRAS - Principle Senior Scientist for Water Treatment
Position: Other
Employer: Philips (China) Investment Co.,Ltd