Article

Imaging of the Achilles tendon in spondyloarthritis: a comparison of ultrasound and conventional, short and ultrashort echo time MRI with and without intravenous contrast.

Leeds Musculoskeletal Biomedical Research Centre, University of Leeds, Chapel Allerton Hospital, Leeds, UK.
European Radiology (Impact Factor: 4.34). 12/2010; 21(6):1144-52. DOI: 10.1007/s00330-010-2040-z
Source: PubMed

ABSTRACT To compare conventional MRI, ultrashort echo time MRI and ultrasound for assessing the extent of tendon abnormalities in spondyloarthritis.
25 patients with spondyloarthritis and Achilles symptoms were studied with MRI and ultrasound. MR images of the Achilles tendon were acquired using T1-weighted spin echo, gradient echo and ultrashort echo time (UTE) sequences with echo times (TE) between 0.07 and 16 ms, before and after intravenous contrast medium. Greyscale and power Doppler ultrasound were also performed. The craniocaudal extent of imaging abnormalities measured by a consultant musculoskeletal radiologist was compared between the different techniques.
Abnormalities were most extensive on spoiled gradient echo images with TE = 2 ms. Contrast enhancement after intravenous gadolinium was greatest on the UTE images (TE = 0.07 ms). Fewer abnormalities were demonstrated using unenhanced UTE. Abnormalities were more extensive on MRI than ultrasound. Contrast enhancement was more extensive than power Doppler signal.
3D spoiled gradient echo images with an echo time of 2 ms demonstrate more extensive tendon abnormalities than the other techniques in spondyloarthritis. Abnormalities of vascularity are best demonstrated on enhanced ultrashort echo time images.

0 Bookmarks
 · 
68 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: The objective of this study was to demonstrate the feasibility of depicting the internal structure of the Achilles tendon in vivo using high-resolution 3-dimensional ultrashort echo-time (UTE) magnetic resonance imaging at 7 T. For our UTE imaging, a minimum-phase radiofrequency pulse and an anisotropic field-of-view 3-dimensional radial acquisition were used to minimize the echo time and scan time. A fat saturation pulse was applied every 8 spoke acquisitions to reduce blurring and chemical shift artifacts from fat and to improve the dynamic range of the tendon signal. Five healthy volunteers and 1 patient were scanned with an isotropic spatial resolution of up to 0.6 mm. Fat-suppressed UTE images were qualitatively evaluated and compared with non-fat-suppressed UTE images and longer echo-time images. High-resolution UTE imaging was able to visualize the microstructure of the Achilles tendon. Fat suppression substantially improved the depiction of the internal structure. The UTE images revealed a fascicular pattern in the Achilles tendon and fibrocartilage at the tendon insertion. In a patient who had tendon elongation surgery after birth, there was a clear depiction of disrupted tendon structure. High-resolution fat-suppressed 3-dimensional UTE imaging at 7 T allows for the evaluation of the Achilles tendon microstructure in vivo.
    Investigative radiology 02/2014; · 4.85 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: PURPOSE: The aim of this study was to implement a time effective 1-1 double pulse water-selective excitation (WE) into a three-dimensional ultrashort echo time (UTE) sequence (WE-UTE) for visualization of short-T(2) tissues with positive contrast and sufficient suppression of surrounding fat. METHODS: First, an analytical description of magnetization components in the steady state applying WE-UTE was derived and results were compared with numerical simulations based on Bloch's equations. Parameters were optimized for best positive contrast between short-T(2) tissues and fat under consideration of variable relaxation properties over a broad range. Maximal signal yield and signal efficiency of on-resonant protons were compared with UTE sequences with and without off-resonance fat saturation (FatSat). WE-UTE was exemplarily applied for in-vivo musculoskeletal imaging on a 3T whole-body MR unit. RESULTS: Steady state magnetization of WE-UTE could be described analytically and showed excellent accordance with numerical simulations. Even for tissues with T(2) = 1 ms WE-UTE resulted in 79% of maximal signal yield of UTE without FatSat and was more efficient regarding signal yield if compared with UTE with FatSat. Using WE-UTE in-vivo tendons and ligaments could be well delineated with positive contrast to surrounding fat. CONCLUSION: WE-UTE provides a quick method for visualizing short-T(2) tissues with positive contrast. Magn Reson Med, 2013. © 2013 Wiley Periodicals, Inc.
    Magnetic Resonance in Medicine 02/2013; · 3.27 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: In recent years there has been an increased focus on use of imaging for diagnosis and assessment of spondyloarthritis (SpA). Magnetic resonance imaging (MRI) has attracted particular interest for its potential to improve diagnostic certainty for early, non-radiographic disease and to assist clinical decision-making. This report summarizes recent developments toward definition of positive sacroiliac joint and spine MRIs for SpA, with erosion as the major determinant for disease classification. The report also highlights recent SpA imaging work relevant to daily practice, focusing on limitations and challenges of SpA imaging and, in particular, on unsolved practical difficulties of using MRI in SpA. Recent data suggest that SpA imaging in daily practice may not be confined to identification and assessment of disease; it may also become essential for monitoring, clinical decision making, and selecting the most appropriate treatment for patients with SpA. Improved use of imaging may have much potential to enable better management of SpA.
    Current Rheumatology Reports 08/2013; 15(8):345.