Article

Combined evaluation of frequency doubling technology perimetry and scanning laser ophthalmoscopy for glaucoma detection using automated classification.

Department of Ophthalmology and University Eye Hospital, Erlangen, Germany.
Journal of glaucoma (impact factor: 1.74). 12/2010; 21(1):27-34. DOI:10.1097/IJG.0b013e3182027766 pp.27-34
Source: PubMed

ABSTRACT To develop a diagnostic setup with classification rules for combined analysis of morphology [Heidelberg Retina Tomograph (HRT)] and function [frequency doubling technology (FDT) perimetry] measurements.
We used 2 independent case-control studies from the Erlangen eye department as learning and test data for automated classification using random forests. One eye of 334 open angle glaucoma patients and 254 controls entered the study. All individuals underwent HRT scanning tomography of the optic disc, FDT screening, conventional perimetry, and evaluation of fundus photographs. Random forests were learned on individuals of the Erlangen glaucoma registry (102 preperimetric patients, 130 perimetric patients, 161 controls). The classification performances of random forests and built-in classifiers were examined by receiver operator characteristic analysis on an independent second cohort of individuals (47 preperimetric patients, 55 perimetric patients, 93 controls).
HRT measurements had a higher diagnostic power for early glaucomas and FDT perimetry for glaucoma patients with visual field loss. A combination of all parameters using automated classification was superior to single tests in comparison to the diagnostic instrument with the higher diagnostic power in the respective group. Highest sensitivities at a fixed specificity (95%) in the patients of the present test population were: HRT=32%, FDT=19%, combined analysis=47% in preperimetric patients and HRT=76%, FDT=89%, combined analysis=96% in perimetric patients.
The feasibility of machine learning for medical diagnostic assistance could be demonstrated in patients from 2 independent study populations. A predictive model using automated classification is able to combine the advantages of morphology and function, resulting in a higher diagnostic power for glaucoma detection.

0 0
 · 
0 Bookmarks
 · 
29 Views

Keywords

102 preperimetric patients
 
2 independent case-control studies
 
2 independent study populations
 
55 perimetric patients
 
93 controls
 
classification performances
 
Erlangen glaucoma registry
 
FDT screening
 
fixed specificity
 
function [frequency doubling technology
 
glaucoma detection
 
higher diagnostic power
 
Highest sensitivities
 
HRT scanning tomography
 
independent second cohort
 
medical diagnostic assistance
 
morphology [Heidelberg Retina Tomograph
 
receiver operator characteristic analysis
 
test data
 
visual field loss