Article

Ultrasound appearances after mesh implantation - Evidence of mesh contraction or folding?

Department of Obstetrics and Gynecology, First Faculty of Medicine, Charles University in Prague and General University Hospital, Apolinarska 18, Prague 2 128 00, Czech Republic.
International Urogynecology Journal (Impact Factor: 2.16). 10/2010; 22(5):529-33. DOI: 10.1007/s00192-010-1308-9
Source: PubMed

ABSTRACT Polypropylene meshes are frequently used in abdominal and vaginal reconstructive surgery. Recently, several authors have claimed that mesh-associated complications may be linked to mesh shrinkage. We have performed a prospective study with postoperative follow-up by ultrasound examination at two time points after Prolift anterior implantation to assess changes in the ultrasound appearance of mesh implants over time.
We assessed 36 patients who had undergone mesh implantation with Prolift anterior mesh for the correction of symptomatic anterior vaginal wall prolapse. During the surgery, we measured the actual midline length of the mesh (initial length). On the fourth postoperative day, we performed a vaginal ultrasound examination (US) to measure mesh length in the midsagittal plane. A second US was performed 3-5 months after surgery to repeat this measurement.
There was a significant difference in mesh length determined before and 4 days after surgery (90.3 vs. 57.1 mm, P = <0.0001) indicating intraoperative folding. On comparing early and late postoperative ultrasound measurements, there was a reduction in length from 57.1 to 48.3 mm (P < 0.0001), indicating possible shrinkage or retraction.
Intraoperative folding seems to be responsible for a large part of the difference between preoperative (in vitro) and postoperative (US) measurements of mesh dimensions, suggesting that surgical techniques may require adjustment.

3 Followers
 · 
320 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Over the last 20 years, ultrasound has largely replaced radiological methods in the investigation of pelvic floor disorders. Transrectal, transvaginal/ introital and transperineal/ translabial methods have been investigated, with the transperineal/ translabial approach currently the most widespread due to ease of use and the fact that equipment is available almost universally. Position and mobility of the bladder neck, bladder wall thickness, pelvic floor muscle activity and pelvic organ prolapse can be quantified, and Color Doppler may be used to document stress urinary incontinence. As a consequence, both preoperative assessment and audit activities in the field of pelvic reconstructive surgery have been markedly enhanced. This has been most evident in the evaluation of new synthetic slings and implants which usually are highly echogenic, making ultrasound the imaging method of choice for the evaluation of such grafts. Most recently, 3D translabial and transvaginal ultrasound have given access to the axial plane, allowing imaging of paravaginal spaces, the levator hiatus and the pubococcygeus/ puborectalis muscles, i.e., the inferior aspects of the levator ani. The observation of manoeuvres such as a pelvic floor contraction or a Valsalva in the three orthogonal planes, rendered 3D volumes and 4D volume cine clips open up new possibilities for the assessment of functional anatomy, superior to what is currently possible with Magnetic Resonance Imaging. With the latest development, Volume Contrast Imaging (VCI), pelvic floor ultrasound has now reached the spatial resolution of MRI in all three dimensions, while providing far superior temporal resolution. It has become clear that, while there is a wide range of 'normality' in pelvic organ mobility and the dimensions of the levator ani and the hiatus itself, childbirth has a distinct effect on the dimensions of the hiatus and may cause significant soft- tissue trauma that is not apparent at the time of delivery. However, the clinical relevance of such traumatic changes remains to be determined. Much work will need to be done before the full potential of 3D/ 4D pelvic floor ultrasound is realized, both in research and in clinical practice.
    Current Medical Imaging Reviews 04/2006; 2(2):271-290. DOI:10.2174/157340506776930629 · 1.06 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Mesh used for slings and pelvic organ prolapse (POP) repair has resulted in increased efficacy. Yet, the benefits of a more durable repair must be weighed against such risks as vaginal mesh extrusion and erosion and increased dyspareunia, and pelvic pain. We review the current literature on complications seen with the use of vaginal mesh for both stress urinary incontinence and POP. The use of mesh in midurethral slings results in similar efficacy but less morbidity compared with nonmesh sling techniques. The use of mesh in abdominal sacrocolpopexy may result in lower rates of mesh complications compared with transvaginal mesh prolapse repairs. In 2011, the Food and Drug Administration issued an updated safety communication stating that serious complications associated with transvaginal mesh for POP repair are not rare. Yet, certain patients do benefit from the use of transvaginal mesh for POP repair. Better-controlled data are needed to answer questions regarding outcomes, complications, and quality of life after transvaginal mesh prolapse procedures. The surgeon and the patient must have a proper informed consent discussion about the risks, benefits, alternatives, and indications for the use of mesh.
    Current opinion in urology 05/2012; 22(4):287-91. DOI:10.1097/MOU.0b013e32835480b2 · 2.12 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: OBJECTIVES: To analyze different complications of synthetic suburethral slings, and to apply the new "IUGA-ICS classification of complications directly related to the insertion of prosthesis (meshes, implants, tapes) and grafts in female pelvic floor surgery" to the list of complications, check its applicability, and give suggestions regarding possible improvements. STUDY DESIGN: This study is an analysis of complications of synthetic suburethral slings. Data on type of complication, time interval between the insertion of the prosthesis and the onset of symptoms of complication, type and nature of prosthesis, and management process were documented. Additional descriptions of the sling position in relation to lower urinary tract, shrinkage or prominence of the prosthesis, and intra-operative nature of the prosthetic material were collected for analysis. RESULTS: From the year 2003 to 2010, 376 women with complications of synthetic suburethral slings were managed surgically and the data were analyzed. Overactive bladder (OAB) at 54%, lower urinary tract obstruction (48%), vaginal exposure (19%), and pain (14%) were the most frequent complications. Infection, fistulae, urinary tract penetration, and groin/thigh pain were other complications. The new IUGA-ICS classification could be applied to most of the types of complications, a notable exception being de novo development of overactive bladder. Also category 4B of IUGA-ICS classifications encompasses a wide clinical variety of complications and may need reconsideration. CONCLUSION: De novo OAB seems to be the commonest complication of synthetic suburethral slings, followed by obstruction, vaginal exposure, and long term pain. The new IUGA-ICS classification on complications has good general applicability; some minor changes may be useful in the future.
    European journal of obstetrics, gynecology, and reproductive biology 08/2012; 165(2). DOI:10.1016/j.ejogrb.2012.08.011 · 1.63 Impact Factor
Show more