Article

Considerations for the design of safe and effective consumer health IT applications in the home.

Agency for Healthcare Research and Quality, Rockville, Maryland 20850, USA.
Quality and Safety in Health Care (Impact Factor: 2.16). 10/2010; 19 Suppl 3:i61-7. DOI: 10.1136/qshc.2010.041897
Source: PubMed

ABSTRACT Consumer health IT applications have the potential to improve quality, safety and efficiency of consumers' interactions with the healthcare system. Yet little attention has been paid to human factors and ergonomics in the design of consumer health IT, potentially limiting the ability of health IT to achieve these goals. This paper presents the results of an analysis of human factors and ergonomics issues encountered by five projects during the design and implementation of home-based consumer health IT applications.
Agency for Healthcare Research and Quality-funded consumer health IT research projects, where patients used the IT applications in their homes, were reviewed. Project documents and discussions with project teams were analysed to identify human factors and ergonomic issues considered or addressed by project teams. The analysis focused on system design and design processes used as well as training, implementation and use of the IT intervention.
A broad range of consumer health IT applications and diverse set of human factors and ergonomics issues were identified. The design and implementation processes used resulted in poor fit with some patients' healthcare tasks and the home environment and, in some cases, resulted in lack of use. Clinician interaction with patients and the information provided through health IT applications appeared to positively influence adoption and use.
Consumer health IT application design would benefit from the use of human factors and ergonomics design and evaluation methods. Considering the context in which home-based consumer health IT applications are used will likely affect the ability of these applications to positively impact the quality, safety and efficiency of patient care.

0 Followers
 · 
105 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The goal of this paper is to describe the successful application of a use case-based evaluation approach to guide the effective design, evaluation and redesign of inexpensive, commercial, off-the-shelf consumer health informatics (CHI) interventions. Researchers developed four CHI intervention use cases representing two distinct patient populations (patients with diabetes with high blood pressure, post-bariatric surgery patients), two commercial off-the-shelf CHI applications (Microsoft HealthVault, Google Health), and related devices (blood pressure monitor, pedometer, weight scale). Three patient proxies tested each intervention for 10 days. The patient proxies recorded their challenges while completing use case tasks, rating the severity of each challenge based on how much it hindered their use of the intervention. Two independent evaluators categorized the challenges by human factors domain (physical, cognitive, macroergonomic). The use case-based approach resulted in the identification of 122 challenges, with 12% physical, 50% cognitive and 38% macroergonomic. Thirty-nine challenges (32%) were at least moderately severe. Nine of 22 use case tasks (41%) accounted for 72% of the challenges. The study used two patient proxies and addressed two specific patient populations and low-cost, off-the-shelf CHI interventions, which may not perfectly generalize to a larger number of proxies, actual patient populations, or other CHI interventions. CHI designers can employ the use case-based evaluation approach to assess the fit of a CHI intervention with patients' health work, in the context of their daily activities and environment, which would be difficult or impossible to evaluate by laboratory-based studies.
    Journal of the American Medical Informatics Association 07/2011; 19(1):137-42. DOI:10.1136/amiajnl-2011-000338 · 3.93 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Based on barriers to the use of computerized clinical decision support (CDS) learned in an earlier field study, we prototyped design enhancements to the Veterans Health Administration's (VHA's) colorectal cancer (CRC) screening clinical reminder to compare against the VHA's current CRC reminder. In a controlled simulation experiment, 12 primary care providers (PCPs) used prototypes of the current and redesigned CRC screening reminder in a within-subject comparison. Quantitative measurements were based on a usability survey, workload assessment instrument, and workflow integration survey. We also collected qualitative data on both designs. Design enhancements to the VHA's existing CRC screening clinical reminder positively impacted aspects of usability and workflow integration but not workload. The qualitative analysis revealed broad support across participants for the design enhancements with specific suggestions for improving the reminder further. This study demonstrates the value of a human-computer interaction evaluation in informing the redesign of information tools to foster uptake, integration into workflow, and use in clinical practice.
    BMC Medical Informatics and Decision Making 11/2011; 11:74. DOI:10.1186/1472-6947-11-74 · 1.50 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: E-prescribing, the health information technology (HIT) that enables prescribers to electronically transmit prescriptions to community pharmacies, has been touted as a solution for improving patient safety and overall quality of care. However, the impact of HIT, such as e-prescribing on medication errors in acute care settings, has been widely studied and shows that if poorly designed or implemented, HIT can pose a risk to patient safety by introducing a source of medication errors. Unlike acute care settings, safety issues related to e-prescribing in primary care settings (where e-prescriptions are generated and transmitted) and pharmacies (where e-prescriptions are received) have not received as much attention in the literature. This paper provides a focused review of patient safety issues related to using e-prescribing systems in primary care and pharmacies. In addition, the paper proposes using human factors engineering concepts to study e-prescribing safety in pharmacies and primary care settings to identify safety problems and possible mechanisms for improvement.
    Research in Social and Administrative Pharmacy 10/2012; DOI:10.1016/j.sapharm.2012.09.004 · 2.35 Impact Factor

Preview

Download
2 Downloads
Available from