The investigation of ultrasound efficacy in cleaning the surface of new endodontic instruments

Srpski arhiv za celokupno lekarstvo (Impact Factor: 0.23). 01/2009; DOI: 10.2298/SARH0908357P
Source: DOAJ

ABSTRACT Introduction. Active parts and tips of various new stainless steel and nickel-titanium endodontic instruments can be coated with fragments or metal residues, which can become detached during endodontic treatment. These fragments may obstruct the root canals or even reach the periapical tissue during biomechanical preparation and should be removed before clinical use. Objective. The aim of this study was to evaluate the presence of metal residues on both new stainless steel and nickel-titanium endodontic instruments, and to determine the cleaning efficacy of ultrasound using distilled water or disinfectant solution for removing these residues. Methods. Forty-eight stainless steel and nickel-titanium instruments were carefully removed from their original packages with dental tweezers, in order to avoid any contact with the cutting flutes and tips. The instruments were evaluated in term of metal debris presence, using scanning electron microscopy (SEM) and x-ray energy-dispersive spectroscopy (EDS). The instruments were then removed from the electron microscopy analysis stubs and placed in an ultrasonic bath for 15 minutes at a frequency of 28 kHz, using distilled water or disinfectant solution. The surfaces of the instruments were re-evaluated after cleaning. Results. Before ultrasound cleaning, a larger amount of metal debris was observed on the nickel-titanium endodontic instruments when compared to those made of stainless steel. The presence of metal particles on the instruments was evaluated by using EDS analysis. The use of ultrasound was effective in removing the metal residues from both types of endodontic instrument surfaces. Conclusion. The use of ultrasound proved to be an efficient method for the removal of metal particles from the surface of new stainless steel and nickel-titanium endodontic instruments.

0 Bookmarks
 · 
102 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The nickel-titanium alloy Nitinol has been used in the manufacture of endodontic instruments in recent years. Nitinol alloys have greater strength and a lower modulus of elasticity compared with stainless steel alloys. The super-elastic behaviour of Nitinol wires means that on unloading they return to their original shape following deformation. These properties are of interest in endodontology as they allow construction of root canal instruments that utilize these favourable characteristics to provide an advantage when preparing curved canals. This review aims to provide an overview of Nitinol alloys used in dentistry in order for its unique characteristics to be appreciated.
    International Endodontic Journal 08/2000; 33(4):297-310. · 2.05 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The aim of this study was to evaluate the efficacy of ultrasound in cleaning the surface of stainless steel and Ni-Ti endodontic instruments. Twenty nickel-titanium instruments (10 Quantec files and 10 Nitiflex) and 20 stainless steel K-files (10 Maillefer-Dentsply and 10 Moyco Union Broach) were removed from their original packages and evaluated using a scanning electron microscope. Scores were given for the presence of residues on the surface of the instruments. The instruments were then cleaned in an ultrasonic bath containing only distilled water or detergent solution for 15 min, and re-evaluated, using scanning electron microscopy. Before cleaning, a greater amount of metallic debris was observed on the nickel-titanium Quantec instruments (P < 0.05), when compared to those made of stainless steel. Statistical analysis showed that the use of ultrasound was effective for cleaning the instruments, regardless of the irrigating solution or the instruments type (P < 0.05). The use of ultrasound proved to be an efficient method for the removal of metallic particles from the surface of stainless steel and Ni-Ti endodontic instruments.
    International Endodontic Journal 01/2002; 34(8):581-5. · 2.05 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The purpose of this preliminary study was to analyze surface irregularities on ProFile nickel-titanium (NiTi) rotary instruments before use, after sterilization by two different methods and after instrumentation of molar root canals. Five new ProFile NiTi rotary instruments with 0.04 taper, size 20, five instruments with 0.04 taper, size 25 and five with 0.06 taper, size 20 were analyzed by scanning electron microscopy (SEM) and X-ray energy-dispersive spectroscopy (EDS). The instruments were then divided into two groups: three of each taper and size were sterilized in a dry heat sterilizer, whilst two of each taper and size were sterilized in an autoclave. After inspection by the same techniques, the files were used to instrument six molar root canals, and again analyzed by SEM/EDS. Together with the usual machining defects, a variable amount of material containing mainly carbon and sulphur was found on the surface of new instruments. This material was not removed by standard cleaning and sterilization procedures. The use of the files for instrumentation of root canals eliminated a considerable amount of the adhered substance, but deposits rich in calcium and phosphorus accumulated on the remaining impurities. The adherence of dentine on surface deposits found on new ProFile instruments requires special cleaning, prior to sterilization.
    International Endodontic Journal 11/2002; 35(10):848-53. · 2.05 Impact Factor