Motorization of a surgical microscope for intra-operative navigation and intuitive control. Int J Med Robot Comput Assist Surg

Institute for Robotics and Cognitive Systems, University of Lübeck, Germany.
International Journal of Medical Robotics and Computer Assisted Surgery (Impact Factor: 1.53). 09/2010; 6(3):269-80. DOI: 10.1002/rcs.314
Source: PubMed


During surgical procedures, various medical systems, e.g. microscope or C-arm, are used. Their precise and repeatable manual positioning can be very cumbersome and interrupts the surgeon's work flow. Robotized systems can assist the surgeon but they require suitable kinematics and control. However, positioning must be fast, flexible and intuitive.
We describe a fully motorized surgical microscope. Hardware components as well as implemented applications are specified. The kinematic equations are described and a novel control concept is proposed.
Our microscope combines fast manual handling with accurate, automatic positioning. Intuitive control is provided by a small remote control mounted to one of the surgical instruments. Positioning accuracy and repeatability are < 1 mm and vibrations caused by automatic movements fade away in about 1 s.
The robotic system assists the surgeon, so that he can position the microscope precisely and repeatedly without interrupting the clinical workflow. The combination of manual und automatic control guarantees fast and flexible positioning during surgical procedures.

Download full-text


Available from: Achim Schweikard, Dec 12, 2014
1 Follower
19 Reads
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: For robotized transcranial magnetic stimulation (TMS), the magnetic coil is placed on the patient's head by a robot. As the robotized TMS system requires tracking of head movements, robot and tracking camera need to be calibrated. However, for robotized TMS in a clinical setting, such calibration is required frequently. Mounting/unmounting a marker to the end effector and moving the robot into different poses is impractical. Moreover, if either system is moved during treatment, recalibration is required. To overcome this limitation, we propose to directly track a marker at link three of the articulated arm. Using forward kinematics and a constant marker transform to link three, the calibration can be performed instantly. Our experimental results indicate an accuracy similar to standard hand-eye calibration approaches. It also outperforms classical hand-held navigated TMS systems. This robust online calibration greatly enhances the system's user-friendliness and safety.
    International Journal of Medical Robotics and Computer Assisted Surgery 12/2011; 7(4):414-22. DOI:10.1002/rcs.411 · 1.53 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: With its high spatial and temporal resolution, optical coherence tomography (OCT) is an ideal modality for intra-operative imaging. One possible application is to detect tumour invaded tissue in neurosurgery, e.g. during complete resection of glioblastoma. Ideally, the whole resection cavity is scanned. However, OCT is limited to a small field of view (FOV) and scanning perpendicular to the tissue surface. We present a new method to use OCT for scanning of the resection cavity during neurosurgical resection of brain tumours. The main challenges are creating a map of the cavity, scanning perpendicular to the surface and merging the three-dimensional (3D) data for intra-operative visualization and detection of residual tumour cells. Our results indicate that the proposed method enables creating high-resolution maps of the resection cavity. An overlay of these maps with the microscope images provides the surgeon with important information on the location of residual tumour tissue underneath the surface. We demonstrated that it is possible to automatically acquire an OCT image of the complete resection cavity. Overlaying microscopy images with depth information from OCT could lead to improved detection of residual tumour cells.
    International Journal of Medical Robotics and Computer Assisted Surgery 09/2012; 8(3):327-36. DOI:10.1002/rcs.1425 · 1.53 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: This paper presents an approach for understanding the soft tissue behavior in surface contact with a hard object scanning the tissue. The application domain is confocal microlaparoscope imaging, mostly used for imaging the outer surface of the organs in the abdominal cavity. The probe (optic-head) is swept over the tissue to collect sequential images to obtain a large field of view with mosaicing. The problem we address is that the tissue also moves with the probe due to its softness; therefore the resulting mosaic is not in the same shape and dimension as traversed by the probe. Our approach inspires from the finger slip studies and adapts the idea of load-and-slip that explains the movement of the finger when dragged on a hard surface. We propose the concept of loading-distance and perform measurements with in total 84 experiments on beef liver and chicken breast tissues. Our results indicate that the loading-distance can be measured prior to a scan and be used during the scan in order to compensate the movement of the probe. In this way we can have an image-mosaic of the tissue surface in a desired shape.
    Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems 10/2012; DOI:10.1109/IROS.2012.6385915
Show more