Impact of Mechanical Unloading on Microvasculature and Associated Central Remodeling Features of the Failing Human Heart

Cardiovascular Department and Utah Artificial Heart Program, Intermountain Medical Center, Salt Lake City, Utah, USA.
Journal of the American College of Cardiology (Impact Factor: 16.5). 07/2010; 56(5):382-91. DOI: 10.1016/j.jacc.2010.04.019
Source: PubMed


This study investigates alterations in myocardial microvasculature, fibrosis, and hypertrophy before and after mechanical unloading of the failing human heart.
Recent studies demonstrated the pathophysiologic importance and significant mechanistic links among microvasculature, fibrosis, and hypertrophy during the cardiac remodeling process. The effect of left ventricular assist device (LVAD) unloading on cardiac endothelium and microvasculature is unknown, and its influence on fibrosis and hypertrophy regression to the point of atrophy is controversial.
Hemodynamic data and left ventricular tissue were collected from patients with chronic heart failure at LVAD implant and explant (n = 15) and from normal donors (n = 8). New advances in digital microscopy provided a unique opportunity for comprehensive whole-field, endocardium-to-epicardium evaluation for microvascular density, fibrosis, cardiomyocyte size, and glycogen content. Ultrastructural assessment was done with electron microscopy.
Hemodynamic data revealed significant pressure unloading with LVAD. This was accompanied by a 33% increase in microvascular density (p = 0.001) and a 36% decrease in microvascular lumen area (p = 0.028). We also identified, in agreement with these findings, ultrastructural and immunohistochemical evidence of endothelial cell activation. In addition, LVAD unloading significantly increased interstitial and total collagen content without any associated structural, ultrastructural, or metabolic cardiomyocyte changes suggestive of hypertrophy regression to the point of atrophy and degeneration.
The LVAD unloading resulted in increased microvascular density accompanied by increased fibrosis and no evidence of cardiomyocyte atrophy. These new insights into the effects of LVAD unloading on microvasculature and associated key remodeling features might guide future studies of unloading-induced reverse remodeling of the failing human heart.

Download full-text


Available from: Mohamed E Salama,
  • Source
    • "For the evaluation of fibrosis, sections were stained with Masson Trichrome, and 15 random fields were selected. Automated image analysis was done using a colour deconvolution algorithm [6], and myocardial fibrosis was calculated with the use of Image J (National Institute of Health, Bethesda, USA), a commonly used technique [7]. Any field containing a large scar area was excluded so that quantification reflected interstitial fibrosis only. "
    [Show abstract] [Hide abstract]
    ABSTRACT: During support with a left ventricular assist device (LVAD), partial reverse remodelling takes place in which fibrosis plays an important role. In this study, we analysed the histological changes and expression of fibrotic markers in patients with advanced heart failure (HF) during continuous-flow LVAD (cf-LVAD) support. In 25 patients, myocardial tissue at the time of LVAD implantation (pre-LVAD) was compared with tissue from the explanted left ventricle (post-LVAD). Interstitial fibrosis and cardiomyocyte size were analysed pre- and post-LVAD. Plasma was obtained from all patients before and during LVAD support. Plasma levels, cardiac mRNA and protein expression of brain natriuretic peptide (BNP), galectin-3 (Gal-3), connective tissue growth factor (CTGF), osteopontin (OPN) and transforming growth factor β-1 were determined. Fibrosis increased during cf-LVAD unloading (P < 0.05). Cardiomyocytes elongated (P < 0.05), whereas cross-sectional area did not change. BNP, Gal-3, CTGF and OPN were significantly elevated pre-LVAD in comparison with controls. BNP decreased significantly after 1 month of cf-LVAD support (P < 0.001) to near-normal levels. Pro-fibrotic markers remained elevated in comparison with controls. cf-LVAD support is associated with lengthening of cardiomyocytes, without alterations in diameter size. Remarkably, myocardial fibrosis increased as well as circulating pro-fibrotic markers. Whether the morphological changes are a direct effect of reduced pulsatility during cf-LVAD support or due to HF progression requires further investigation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
    European journal of cardio-thoracic surgery: official journal of the European Association for Cardio-thoracic Surgery 01/2015; 48(3). DOI:10.1093/ejcts/ezu539 · 3.30 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The GRAPHOTRON is a uniform high resolution, high brightness CRT display which provides a high speed sub raster for character generation and is capable of 5000 line resolution and geometrical accuracy of 0.01%. This paper outlines the cathode ray tube and associated focus-deflection component characteristics required to achieve a precision high resolution display for electronic photocomposition, graphic reproduction, flying spot scanner, computer readout and similar applications. Correction of electron beam distortions due to focusing and deflection and a variety of geometric distortions including radial nonlinearity, nonorthogonality, center line bow, sub raster distortions and other pattern errors introduced by deflection and optical components will be discussed.
    IEEE Transactions on Electron Devices 07/1968; 13(6-15):430 - 430. DOI:10.1109/T-ED.1968.16316 · 2.47 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Robustness properties of nonlinear extended Kalman filters with constant gains and modeling errors are presented. Sufficient conditions for the nondivergence of state estimates generated by such nonlinear estimators are given. In addition, the overall robustness and stability properties of closed-loop stochastic regulators, based upon the linear-quadratic Gaussian design methodology using linearized dynamics, are presented; the sufficient conditions for closed-loop stability have a "separation-type" property.
    IEEE Transactions on Automatic Control 09/1978; 23(4-23):717 - 725. DOI:10.1109/TAC.1978.1101825 · 2.78 Impact Factor
Show more