Weiduschat N, Habedank B, Lampe B, Poggenborg J, Schuster A, Haupt WF, Heiss WD, Thiel ALocalizing Broca's area for transcranial magnetic stimulation: comparison of surface distance measurements and stereotaxic positioning. Brain Stimul 2:93-102

Department of Neurology, University of Cologne, Cologne, Germany.
Brain Stimulation (Impact Factor: 4.4). 04/2009; 2(2):93-102. DOI: 10.1016/j.brs.2008.09.005
Source: PubMed


Precise placement of transcranial magnetic stimulation (TMS) coils over target regions is crucial for correct interpretation of TMS effects. Modern frameless stereotaxic systems yield high accuracy, but require extensive equipment and cannot be used in every setting, for example, during functional imaging sessions.
The aim of this study was the development of a method for TMS-coil placement based on individual imaging data without the need for external tracking devices.
We compared coil positioning over Broca's area using an advanced stereotaxic navigation system with placement according to the surface distance measurements (SDM) method. By using the SDM-method, 3-dimensional renderings adapted from individual T1-weighted magnetic resonance imaging (MRI) data were created to identify Broca's area and Broca's homologue, respectively, and to define anatomic landmarks on the skin's surface. Distances between these landmarks were used to localize the real target on the individual's head.
The mean Euclidean distance between surface positions as determined with the two methods was 8.31 mm and the mean difference of estimated virtual electric field intensity at the target point was 7.37 V/m corresponding to 4.01% of maximum field strength.
Our findings suggest that, compared with a state-of-the-art frameless stereotaxy system, the SDM-method yields a reasonable accuracy for positioning of a TMS-coil over Broca's area in terms of spatial coordinates.

Download full-text


Available from: Nora Weiduschat, Oct 06, 2015
63 Reads
  • Source
    • "This peak voxel activity was elicited by the automatic speech task. The surface distance measurements method was used to identify the location of the selected region on the head of each participant (Weiduschat et al., 2009). The same iTBS procedure was used in the sham-rTMS phase, but a sham TMS coil was substituted for the real TMS coil. "
    [Show abstract] [Hide abstract]
    ABSTRACT: The purpose of this study was to investigate whether or not the right hemisphere can be engaged using Melodic Intonation Therapy (MIT) and excitatory repetitive transcranial magnetic stimulation (rTMS) to improve language function in people with aphasia. The two participants in this study (GOE and AMC) have chronic non-fluent aphasia. A functional Magnetic Resonance Imaging (fMRI) task was used to localize the right Broca's homolog area in the inferior frontal gyrus for rTMS coil placement. The treatment protocol included an rTMS phase, which consisted of 3 treatment sessions that used an excitatory stimulation method known as intermittent theta burst stimulation, and a sham-rTMS phase, which consisted of 3 treatment sessions that used a sham coil. Each treatment session was followed by 40 min of MIT. A linguistic battery was administered after each session. Our findings show that one participant, GOE, improved in verbal fluency and the repetition of phrases when treated with MIT in combination with TMS. However, AMC showed no evidence of behavioral benefit from this brief treatment trial. Post-treatment neural activity changes were observed for both participants in the left Broca's area and right Broca's homolog. These case studies indicate that a combination of MIT and rTMS applied to the right Broca's homolog has the potential to improve speech and language outcomes for at least some people with post-stroke aphasia.
    Frontiers in Psychology 02/2014; 5:37. DOI:10.3389/fpsyg.2014.00037 · 2.80 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Although functional imaging studies suggest that recruitment of contralesional areas hinders optimal functional reorganization in patients with aphasic stroke, only limited evidence is available on the efficacy of noninvasive brain stimulation such as repetitive transcranial magnetic stimulation aimed at suppression of contralateral overactivation. In this randomized, controlled, blinded pilot study, the effect of 1-Hz repetitive transcranial magnetic stimulation over right-hemispheric Broca homolog in subjects with poststroke aphasia in the subacute stage was examined. According to their group allocation, patients received, in addition to conventional speech and language therapy, multiple sessions of repetitive transcranial magnetic stimulation either over the right-hemispheric inferior frontal gyrus (intervention group) or over the vertex (control group). The primary outcome parameter was the change in laterality indices as quantified by activation positron emission tomography before and after the 2-week intervention period. The clinical efficacy was evaluated with the Aachen Aphasia Test. At baseline, no group differences were discovered for age, laterality indices, or mean Aachen Aphasia Test scores. Four patients were lost to follow-up, but none due to side effects of the transcranial magnetic stimulation. Positron emission tomography revealed an activation shift toward the right hemisphere in the control group (P=0.0165), which was absent in the intervention group. Furthermore, the latter improved significantly clinically by a mean of 19.8 points in the Aachen Aphasia Test total score (P=0.002), whereas the control group did not. There was however no clear linear relationship between the extent of laterality shift and clinical improvement (r=0.193, P=nonsignificant). Repetitive transcranial magnetic stimulation might be an effective, safe, and feasible complementary therapy for poststroke aphasia.
    Stroke 02/2011; 42(2):409-15. DOI:10.1161/STROKEAHA.110.597864 · 5.72 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Transcranial direct current stimulation (tDCS) is a noninvasive brain stimulation technique that induces changes in cortical excitability: anodal stimulation increases while cathodal stimulation reduces excitability. Imaging studies performed after unilateral stimulation have shown conflicting results regarding the effects of tDCS on surrogate markers of neuronal activity. The aim of this study was to directly measure these effects on activation-induced changes in regional cerebral blood flow (ΔrCBF) using positron emission tomography (PET) during bilateral tDCS. Nine healthy subjects underwent repeated rCBF measurements with (15)O-water and PET during a simple motor task while receiving tDCS or sham stimulation over the primary motor cortex (M1). Motor evoked potentials (MEPs) were also assessed before and after real and sham stimulation. During tDCS with active movement, ΔrCBF in M1 was significantly lower on the cathodal than the anodal side when compared with sham stimulation. This decrease in ΔrCBF was accompanied by a decrease in MEP amplitude on the cathodal side. No effect was observed on resting or activated rCBF relative to sham stimulation. We thus conclude that it is the interaction of cathodal tDCS with activation-induced ΔrCBF rather than the effect on resting or activated rCBF itself which constitutes the physiological imaging correlate of tDCS.
    Journal of cerebral blood flow and metabolism: official journal of the International Society of Cerebral Blood Flow and Metabolism 05/2011; 31(10):2086-95. DOI:10.1038/jcbfm.2011.72 · 5.41 Impact Factor
Show more