Article

High resolution multimodal clinical ophthalmic imaging system

Physical Sciences Inc., 20 New England Business Center, Andover MA 01810, USA.
Optics Express (Impact Factor: 3.53). 05/2010; 18(11):11607-21. DOI: 10.1364/OE.18.011607
Source: PubMed

ABSTRACT We developed a multimodal adaptive optics (AO) retinal imager which is the first to combine high performance AO-corrected scanning laser ophthalmoscopy (SLO) and swept source Fourier domain optical coherence tomography (SSOCT) imaging modes in a single compact clinical prototype platform. Such systems are becoming ever more essential to vision research and are expected to prove their clinical value for diagnosis of retinal diseases, including glaucoma, diabetic retinopathy (DR), age-related macular degeneration (AMD), and retinitis pigmentosa. The SSOCT channel operates at a wavelength of 1 microm for increased penetration and visualization of the choriocapillaris and choroid, sites of major disease activity for DR and wet AMD. This AO system is designed for use in clinical populations; a dual deformable mirror (DM) configuration allows simultaneous low- and high-order aberration correction over a large range of refractions and ocular media quality. The system also includes a wide field (33 deg.) line scanning ophthalmoscope (LSO) for initial screening, target identification, and global orientation, an integrated retinal tracker (RT) to stabilize the SLO, OCT, and LSO imaging fields in the presence of lateral eye motion, and a high-resolution LCD-based fixation target for presentation of visual cues. The system was tested in human subjects without retinal disease for performance optimization and validation. We were able to resolve and quantify cone photoreceptors across the macula to within approximately 0.5 deg (approximately 100-150 microm) of the fovea, image and delineate ten retinal layers, and penetrate to resolve features deep into the choroid. The prototype presented here is the first of a new class of powerful flexible imaging platforms that will provide clinicians and researchers with high-resolution, high performance adaptive optics imaging to help guide therapies, develop new drugs, and improve patient outcomes.

0 Followers
 · 
94 Views
  • [Show abstract] [Hide abstract]
    ABSTRACT: Recent progress in retinal image acquisition techniques, including optical coherence tomography (OCT) and scanning laser ophthalmoscopy (SLO), combined with improved performance of adaptive optics (AO) instrumentation, has resulted in improvement in the quality of in vivo images of cellular structures in the human retina. Here, we present a short review of progress on developing AO-OCT instruments. Despite significant progress in imaging speed and resolution, eye movements present during acquisition of a retinal image with OCT introduce motion artifacts into the image, complicating analysis and registration. This effect is especially pronounced in high-resolution datasets acquired with AO-OCT instruments. Several retinal tracking systems have been introduced to correct retinal motion during data acquisition. We present a method for correcting motion artifacts in AO-OCT volume data after acquisition using simultaneously captured adaptive optics-scanning laser ophthalmoscope (AO-SLO) images. We extract transverse eye motion data from the AO-SLO images, assign a motion adjustment vector to each AO-OCT A-scan, and re-sample from the scattered data back onto a regular grid. The corrected volume data improve the accuracy of quantitative analyses of microscopic structures.
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Photoacoustic (PA) imaging is a hybrid biomedical imaging method that exploits both acoustical Epub ahead of print and optical properties and can provide both functional and structural information. Therefore, PA imaging can complement other imaging methods, such as ultrasound imaging, fluorescence imaging, optical coherence tomography, and multi-photon microscopy. This article reviews techniques that integrate PA with the above imaging methods and describes their applications.
    02/2015; DOI:10.14366/usg.14062
  • [Show abstract] [Hide abstract]
    ABSTRACT: The performance of clinical confocal SLO and OCT imagers is limited by ocular aberrations. Adaptive optics (AO) addresses this problem, but most research systems are large, complex, and less well suited to the clinical environment. PSI's recently developed compact retinal imager is designed for rapid, automated generation of cone photoreceptor density maps. The device has a compact foot-print suitable for clinical deployment. The system previously presented at Photonics West and ARVO 2013 has been upgraded to include numerous new features that support clinical research applications. These upgrades significantly enhance the capabilities of the imager, providing the clinician with simultaneously-acquired (registered) en face photoreceptor images and AO-OCT retinal cross-sections.
    Proceedings of SPIE - The International Society for Optical Engineering 01/2014; DOI:10.1117/12.2040261 · 0.20 Impact Factor