Article

pi-Selective stationary phases: (III) Influence of the propyl phenyl ligand density on the aromatic and methylene selectivity of aromatic compounds in reversed phase liquid chromatography

Australian Centre for Research on Separation Science, School of Natural Sciences, University of Western Sydney Node, Parramatta, NSW, Australia.
Journal of Chromatography A (Impact Factor: 4.26). 08/2010; 1217(33):5377-83. DOI: 10.1016/j.chroma.2010.05.029
Source: PubMed

ABSTRACT The retention characteristics of phenyl type stationary phases for reversed phase high performance liquid chromatography are still largely unknown. This paper explores the retention process of these types of stationary phases by examining the retention behaviour of linear PAHs and n-alkylbenzenes on a series of propyl phenyl stationary phases that have changes in their ligand density (1.23, 1.31, 1.97, 2.50 micromol m(-2)). The aromatic and methylene selectivities increased with increasing ligand density until a point where a plateau was observed, overall the propyl phenyl phases had a higher degree of aromatic selectivity than methylene selectivity indicating that these columns are suitable for separations involving aromatic compounds. Also, retention characteristics relating to the size of the solute molecule were observed to be influenced by the ligand density. It is likely that the changing retention characteristics are caused by the different topologies of the stationary phases at different ligand densities. At high ligand densities, the partition coefficient became constant.

0 Followers
 · 
80 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: Analytical scale silica monoliths are commercially limited to three column selectivities (bare silica, C8 and C18). An in situ modification is reported in detail to overcome this barrier and allow for any functionality of choice to be bonded to the silica surface of the monolithic stationary phase support. The modification method was conducted on a commercial bare silica column to bond the C18 moiety to the silica surface through a silylation reaction. The C18 type of stationary phase was chosen, as this is the most commonly bonded functionality for the majority of stationary phases used for high-performance liquid chromatography (HPLC) separations. The C18-modified monolith’s performance was compared to a commercial C18 monolithic and a particle packed column of the same analytical scale column dimensions (100 × 4.6 mm). The modified C18 monolith proved to be of high quality with an efficiency of 73,267 N m−1, fast analysis times (operated at flow rates up to 3 mL min−1 using a conventional 400 bar HPLC system) and improved resolution of a set of polar and non-polar substituted aromatics in comparison to a commercial C18 monolith.
    Chromatographia 03/2014; 77(9-10). DOI:10.1007/s10337-014-2667-z · 1.37 Impact Factor
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: The synthesis and chromatographic behaviour of an analytical size mixed mode bonded silica monolith was investigated. The monolith was functionalised by an in situ modification process of a bare silica rod with chloro(3-cyanopropyl)dimethyl silane and chlorodimethyl propyl phenyl silane solutions. These ligands were selected in order to combine both resonance and non-resonance π-type bonding within a single separation environment. Selectivity studies were undertaken using n-alkyl benzenes and polycyclic aromatic hydrocarbons in aqueous methanol and acetonitrile mobile phases to assess the methylene and aromatic selectivities of the column. The results fit with the linear solvent strength theory suggesting excellent selectivity of the column was achieved. Comparison studies were performed on monolithic columns that were functionalised separately with cyano and phenyl ligands, suggesting highly conjugated molecules were able to successfully exploit both of the π-type selectivities afforded by the two different ligands on the mixed mode column.This article is protected by copyright. All rights reserved
    Journal of Separation Science 08/2014; 37(15). DOI:10.1002/jssc.201400201 · 2.59 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Monodisperse unfunctionalized polystyrene/divinylbenzene beads were prepared via Ugelstads two-step activated swelling procedure. The modification of the porous structure was achieved in two different ways, by either changing the kind and amount of diluent or the concentration of crosslinker. Overall 10 different types of diluents, both solvent and nonsolvent types, were utilized. In all cases divinylbenzene was used as crosslinking agent in concentrations of 55% and 80%, which are commercially available, and 100%, which had to be synthesized. The size and morphology of these particles were examined with scanning electron microscopy. For the analysis of the internal porous structure inverse size exclusion chromatography was conducted. Depending on the monomer and diluent composition beads in the range of 3.4-4.5μm having a specific surface area from 90 to 1898m(2)/g were synthesized. Separation performance was then also investigated using RP-HPLC with benzene and propylbenzene as analytes. Porous and reversed-phase properties were subsequently linked to explain the observed shift in retention and efficiency. Polymers having the highest specific surface area and the smallest mean pore diameter exhibited the best performance with reduced plate height of 3.1.
    Journal of Chromatography A 07/2014; 1358. DOI:10.1016/j.chroma.2014.06.085 · 4.26 Impact Factor

Full-text

Download
23 Downloads
Available from
Aug 12, 2014