Absorption spectra time evolution of EBT-2 model GAFCHROMIC film.

Medical Physics Unit, McGill University, Montréal H3G 1A4, Québec, Canada.
Medical Physics (impact factor: 2.83). 05/2010; 37(5):2207-14. pp.2207-14
Source: PubMed

ABSTRACT One of the major drawbacks of the current radiochromic film dosimetry protocols is the postirradiation waiting time. In this article, the authors study the postirradiation time evolution of the absorption spectrum of radiochromic EBT-2 GAFCHROMIC film model.
Postirradiation scanning times range from 3 min to 5 days and a dose range extends from 0 to 6 Gy. The authors compare the results of absorption spectra measurements for the latest GAFCHROMIC EBT-2 film model to the absorption spectra of the previous EBT GAFCHROMIC film model. The authors also describe a method that can establish the time error constraints on the postirradiation scanning time that will still provide an acceptable dose error for clinical applications if the protocol employing the shorter postirradiation scanning time is implemented in the clinic.
The two film models experience the very same dose change in net absorbance with sensitivity of the latest EBT-2 model GAFCHROMIC film being slightly lower than its predecessor. The authors show that for two postirradiation scanning times of 30 min and 24 h, the 1% dose error can be achieved if the scanning time window is less than +/- 5 min and +/- 2 h, respectively.
By comparing the resultant change in net absorbance between the latest EBT-2 and previous EBT GAFCHROMIC film models, the authors conclude that the addition of the yellow marker dye to the sensitive layer does not affect dosimetric properties of the latest film model. The authors also describe a procedure by which one can establish an acceptable time window around chosen postirradiation scanning time protocol that would provide an acceptable dose error for practical purposes.

0 0
 · 
0 Bookmarks
 · 
53 Views

Keywords

1% dose error
 
absorption spectra measurements
 
absorption spectrum
 
acceptable time window
 
current radiochromic film dosimetry protocols
 
dose change
 
dose range
 
latest EBT-2
 
latest EBT-2 model GAFCHROMIC film
 
latest film model
 
major drawbacks
 
postirradiation scanning times
 
Postirradiation scanning times range
 
postirradiation time evolution
 
previous EBT GAFCHROMIC film models
 
radiochromic EBT-2 GAFCHROMIC film model
 
resultant change
 
shorter postirradiation scanning time
 
time error constraints
 
two film models experience