In vivo detection of PARACEST agents with relaxation correction.

Centre for Functional and Metabolic Mapping, Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada.
Magnetic Resonance in Medicine (Impact Factor: 3.27). 05/2010; 63(5):1184-92. DOI: 10.1002/mrm.22340
Source: PubMed

ABSTRACT Several pulse sequences have been used to detect paramagnetic chemical exchange saturation transfer (PARACEST) contrast agents in animals to quantify the uptake over time following a bolus injection. The observed signal change is a combination of relaxation effects and PARACEST contrast. The purpose of the current study was to isolate the PARACEST effect from the changes in bulk water relaxation induced by the PARACEST agent in vivo for the fast low-angle shot pulse sequence. A fast low-angle shot-based pulse sequence was used to acquire continuous images on a 9.4-T MRI of phantoms and the kidneys of mice following PARACEST agent (Tm(3+)-DOTAM-Gly-Lys) injection. A WALTZ-16 pulse was applied before every second image to generate on-resonance paramagnetic chemical exchange effects. Signal intensity changes of up to 50% were observed in the mouse kidney in the control images (without a WALTZ-16 preparation pulse) due to altered bulk water relaxation induced by the PARACEST agent. Despite these changes, a clear on-resonance paramagnetic chemical exchange effect of 4-7% was also observed. A four-pool exchange model was used to describe image signal intensity. This study demonstrates that in vivo on-resonance paramagnetic chemical exchange effect contrast can be isolated from tissue relaxation time constant changes induced by a PARACEST agent that dominate the signal change.

0 Bookmarks
 · 
74 Views
  • Source
    [Show abstract] [Hide abstract]
    ABSTRACT: PURPOSE: A main obstacle to in vivo applications of paramagnetic chemical exchange saturation transfer (paraCEST) is interference from endogenous tissue magnetization transfer contrast (MTC). The suitability of excitation-based frequency labeled exchange transfer (FLEX) to separate out such MTC effects in vivo was tested. METHODS: The FLEX sequence measures modulation of the water signal based on the chemical shift evolution of solute proton magnetization as a function of evolution time. Time-domain analysis of this water signal allows identification of different solute components and provides a mechanism to separate out the rapidly decaying MTC components with short effective transverse relaxation time ( T2*) values. RESULTS: FLEX imaging of paraCEST agents was possible in vitro in phantoms and in vivo in mouse kidneys and bladder. The results demonstrated that FLEX is capable of separating out the MTC signal from tissues in vivo while providing a quantitative exchange rate for the rapidly exchanging paraCEST water protons by fitting the FLEX time-domain signal to FLEX theory. CONCLUSIONS: The first in vivo FLEX images of a paraCEST agent were acquired, which allowed separation of the tissue MTC components. These results show that FLEX imaging has potential for imaging the distribution of functional paraCEST agents in biological tissues. Magn Reson Med, 2013. © 2013 Wiley Periodicals, Inc.
    Magnetic Resonance in Medicine 03/2013; · 3.27 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: Chemical Exchange Saturation Transfer (CEST) offers a new type of contrast for MRI that is molecule specific. In this approach, a slowly exchanging NMR active nucleus, typically a proton, possessing a chemical shift distinct from water is selectively saturated and the saturated spin is transferred to the bulk water via chemical exchange. Many molecules can act as CEST agents, both naturally occurring endogenous molecules and new types of exogenous agents. A large variety of molecules have been demonstrated as potential agents, including small diamagnetic molecules, complexes of paramagnetic ions, endogenous macromolecules, dendrimers and liposomes. In this review we described the basic principles of the CEST experiment, with emphasis on the similarity to earlier saturation transfer experiments described in the literature. Interest in quantitative CEST has also resulted in the development of new exchange-sensitive detection schemes. Some emerging clinical applications of CEST are described and the challenges and opportunities associated with translation of these methods to the clinical environment are discussed.
    Journal of Magnetic Resonance 12/2012; · 2.30 Impact Factor
  • [Show abstract] [Hide abstract]
    ABSTRACT: The reduction/oxidation (redox) potential of tissue is tightly regulated in order to maintain normal physiological processes, but is disrupted in disease states. Thus, the development of new tools to map tissue redox potential may be clinically important for the diagnosis of diseases that lead to redox imbalances. One promising area of chemical research is the development of redox-activated probes for mapping tissue through magnetic resonance imaging (MRI). In this review, we summarize several strategies for the design of redox-responsive MRI contrast agents. Our emphasis is on both lanthanideIII and transition metalII/III ion complexes that provide contrast either as T1 relaxivity MRI contrast agents or as paramagnetic chemical exchange saturation transfer (PARACEST) contrast agents. These agents are redox-triggered by a variety of chemical reactions or switches including redox-activated thiol groups, and heterocyclic groups that interact with the metal ion or influence properties of other ancillary ligands. Metal ion centered redox is an approach which is ripe for development by coordination chemists. Redox-triggered metal ion approaches have great potential for creating large differences in magnetic properties that lead to changes in contrast. An attractive feature of these agents is the ease of fine-tuning the metal ion redox potential over a biologically relevant range.
    Journal of inorganic biochemistry 01/2014; · 3.25 Impact Factor

Full-text (2 Sources)

View
34 Downloads
Available from
Jun 6, 2014